Inspect and check your appliance.
In case of evident damages, immediately inform
your
dealer and his carrier.
In case of doubt, do not install the
appliance
until
specialised
tech
-
nicians have thoroughly checked its functions.
Level the
appliance
by adjusting the screw feet.
Level side to side as well as front to
back.
For added safety secure the appliance to a wall by means of a tie down strap. This will
make sure the appliance is secure and stable if mounted on a bench.
Prior to connecting the machine to the water supply and drain and to the
electrical
install
-
ation, make sure that both hydraulic and electric specific requirements
shown
in
the
technical data comply.
Damaged parts must be replaced by original and genuine spare parts.
Water connection
H
2
O supply temperature table
Machine upon
request
Standard
H
2
O Cold
H
2
O Hot
5°C ≤ t < 50°C
50°C≤ t ≤ 6
5
°C
T
able 2
T
able 1
Pressure
Table
Min.
Max.
kPa
kPa
Static Pressure
2
0
0
6
00
Dynamic Pressure
200
350
Water hardne
ss
2
0ppm 90ppm
Before connecting the
appliance
to the incoming water line, a stop valve must be
fixed
to
allow for easy maintenance and repair.
The hydraulic installation must
comply with
local
water authority's regulations.
The water pressure, gauged upstream of the fill solenoid during final rinse (flow
pressure),
should be a minimum 200 kPa.
Try opening other taps on the same line,
to see if
flow
pressure is maintained.
An effective rinsing performance can only be
guaranteed
with
sufficient water pressure.
In order to avoid delivery or pressure
drops, the
appliance
should
be individually connected to a water line as direct as
possible, and the line
having
adequate diameter and delivery.
A static pressure higher that
6
00 kPa requires a pressure reducing valve
upstream
of the
supply line.
The delivery of the water supply line should not be
lower than 10 lit
re
s
per
minute.
All
appliances
should be connected to hot water at a
max. temperature of 65
°C
(130
°C
).
If a cold supply is needed then install according to
the services drawing.
If water pressure is below
15
0kPa, the use of a rinse booster pump is recommended.
Electrical connections are shown on the wiring diagram.
If water
hardness is
highe
r
than
90ppm a water
softener must be installed.
Connect the appliance's water supply with a shut off valve capable of quickly and comp-
letely shutting off water intake.
Make sure that the water supply pressure comes within the values given in the Table 1
.
5