background image

INSTRUCTIONS

 

Th

instruction 

manual

 must be kept with the 

appliance

 for future consultation.

  

If the 

appliance

 is sold or transferred to another user, make sure the 

manual

 always goes with 

the appliance so that the new owner can have the necessary information on operation
and the relative instructions.

T

he instruction booklet must be carefully read before installation and firstuse of the

appliance

.

These instructions are supplied to safeguard the user in compliance with Directive 2006/95/
CE as amended and the “harmonized product Technical Standard” EN 60335-1 and
EN

 

60335-2-58.

I

nstallation must be carried out in accordance with local regulations and in such

 

a manner

that maintenance and minor repairs can be carried out without disconnecting the

 appliance

from services.  

 

Isolating switch(es), shut off valve etc,

 

must be within easy reach

 

of the

appliance

.

  

If in doubt call Rhima Australia or their

 

representative for further information.

No responsibility will be accepted for defects

 

or damages by improper installation. 

 
In no event will Rhima Australia be liable for loss of facilities or other property and

 

such

 

things

as - but not limited to - additional labour costs, loss of revenue or

 

anticipated profits

 

and

other damages of any kind whether direct, indirect, incidental

 

or consequential. 

 
In the event of Rhima Australia supplying special tabling or ancillary equipment

 

the

 

Rhima

engineering department prepares a floor plan at the time of order,

 

based upon

 

the physical

layout of the building (or room) in which the 

appliance

 is to

 

be installed.   

 
The specific requirement of each installation will vary since each dishwashing

 appliance

tabling

 

and layout will differ, due to individual use requirements.

  

The

 

drawing must be

thoroughly checked against the site and verified as to the

 d

imensions and clearances,

location of walls,

 

doors and the like.   

 
Any discrepancies should immediately be reported to the Rhima engineering

 

department. 

 
The instructions contained in 

the operating

 manual

 will

 give important information about

the

 

safety of

 

the installation, the practical use and the maintenance of the appliance.

We recommend to keep it near the 

appliance

 at the disposal of service engineers

 

and

appliance

 operators. 

 
Carry the 

appliance

 into the washing area.

  

Remove shipping carton.

  

The 

appliance 

is fitted

with four adjustable feet. 
 
All packing elements, such as plastic bags, polystyrene strips, foamed polyurethane and
nails are a possible source of danger and should therefore be kept

 

out of the reach of

children and must be disposed of in a safe way.

ATTENTION:

APPLIANCE

 INSTALLATION

Receipt of the appliance

 

4

Summary of Contents for GS-40

Page 1: ...Rhima Australia Tel 1800 659 292 www rhima com au WASHING EQUIPMENT INSTALLATION GUIDE BAR GLASS WASHER GS 40 ...

Page 2: ...and eating utensils It has NOT been designed to wash objects soiled with petrol paint remnants of steel or iron corrosive chemical products such as acids alkalis or solvents or any item that cannot be immersed in water Do not open the appliance door when the appliance is operating The appliance has a safety device which stops operation if the door is accidentally opened Do not sit or lean on the o...

Page 3: ...stallation Any breakdown due to external influences high or low water temperature pressure interruption of electricity supply etc For full information on warranty conditions please refer to our general terms and conditions which are available on our website www rhima com au EACH APPLIANCE HAS AN IDENTIFICATION NUMBER WARRANTY CLAIMS WITHOUT THIS NUMBER WILL NOT BE TAKEN INTO CONSIDERATION THE IDEN...

Page 4: ...rofits and other damages of any kind whether direct indirect incidental or consequential In the event of Rhima Australia supplying special tabling or ancillary equipment the Rhima engineering department prepares a floor plan at the time of order based upon the physical layout of the building or room in which the appliance is to be installed The specific requirement of each installation will vary s...

Page 5: ... The hydraulic installation must comply with local water authority s regulations The water pressure gauged upstream of the fill solenoid during final rinse flow pressure should be a minimum 200 kPa Try opening other taps on the same line to see if flow pressure is maintained An effective rinsing performance can only be guaranteed with sufficient water pressure In order to avoid delivery or pressur...

Page 6: ...et hose to suit A trap must be fitted in the drain line If required a grease trap must be installed between the appliance and the building s drain system check local codes The drain pipe should withstand 70 C 158 F in continuous duty conditions WASTE PIPE FROM DISHWASHER AIR BREAK TO REGULATION NOT MAXIMUM HEIGHT TO ABOVE EXCEED 20MM DISHWASHER NOT RECOMMENDED PUMPED WASTE TUNDISH TRAP BY PLUMBER ...

Page 7: ...ectrical connection All Rhima warewashing appliances are pre wired and supplied complete with connecting cable and appropriate plug This cable should be connected to a separate power supply by means of an isolator or appropriate plug and socket and in such a way that a safe and trouble free use of the appliance is guaranteed This appliance MUST be earthed The heating element of the built in rinse ...

Page 8: ...Rhima Australia Pty Ltd ABN 63 007 242 604 72 74 Woodlands Drive Braeside 3195 PO Box 605 Braeside Vic 3195 Tel 1800 659 292 or 03 8586 5444 Fax 03 8586 5454 www rhima com au ...