TM012 Rheem Electric Water Heaters Service Instructions REV: B
Date of Issue: 03/06
This document is stored and maintained electronically by
Service. All printed copies not bearing this statement in RED are deemed “uncontrolled”
4
Specifications
Model
Maximum Inlet
Pressure (kPa)
Water Connections
Series
Capacity
Rated Capa
city
(Litres)
T & PR Val
ve
Rating (kPa)
With ECV
Without
ECV
Bottom T/stat
setting (ºC)
Inlet
Outlet
T&PR
Bottom T/stat
Type
Anode Length
(mm)
025 25 1400 960 1120 70 RP¾/20 RP½/15
230
053
50
1400
960
1120
75
RP¾/20 RP½/15
490 / 540*
090 80 1400 960 1120 70 RP¾/20 RP½/15
695
135 125 1400 960 1120 70 RP¾/20 RP½/15
1153
170 160 1400 960 1120 70 RP¾/20 RP½/15
1400
270 250 1000 680
800
70 RP¾/20 RP½/15
1153
340 315 1000 680
800
70 RP¾/20 RP½/15
1400
RHE
EMGLAS
111
121
171
191
162
425 400 1000 680
800
70 RP¾/20 RP½/15
Tradesperson Adjustable
1636
270 250 1000 680
800
60 RP¾/20 RP½/15
1153
340 315 1000 680
800
60 RP¾/20 RP½/15
1400
OPTIMA
411
462
425 400 1000 680
800
60 RP¾/20 RP½/15 Consumer
Adjustab
le
1636
Notes:
121 series available in 125, 160, 250 and 315 litre capacities only
171 series available in 50, 80 and 125 litre capacities only
191 series available in 50 litre capacity only
Top thermostat on twin element models set at 60ºC
* 540mm anode fitted to 111050F and 171050F models only
Preventative Maintenance
It is suggested for peak performance that the water heater be serviced annually.
1. Check for discharge from the T&PR valve. When the element is operating a small
discharge of water may be evident. Operate the valve-easing lever to ensure the valve
opens and resets properly. Always open and close the valve gently. The T&PR valve
should be replaced at 5 yearly intervals.
2. Check for leaks at all tank fittings.
3. Check for signs of excessive corrosion on the water heater jacket.
4.
Isolate power
to the water heater and check all electrical connections for signs of
overheating due to poor connection.
5. Conduct an insulation test on the water heater. (Refer to page 25)
6. Rheem Plus models: Service the tempering valve. (Refer to page 32)