RHEEM THERMAL AIR SOURCE HEAT PUMP INSTALLATION, MAINTENANCE & SERVICE MANUAL
RHEEM HOT WATER SYSTEM (ASEAN REGION)
9 |
P a g e
SECTION 2: COMMISSIONING
The Rheem Thermal heat pump is fully charged with refrigerant. The following checks
should be carried out:
a)
Installation and operation instructions should be read prior to commissioning.
b)
The unit should have unrestricted supply of fresh air to the coil and exhaust air
removed from closed in areas.
c)
The unit should stand on a firm base with fall to take condensate or rain water away
from the compressor compartment and to the unit’s drainage at the plumbing
end.
d)
Noise should be directed away from living areas.
e)
Water connected correctly as indicated.
f)
Condensate drain runs to waste.
g)
Unit is wired correctly and has full amperage,
h)
Unit is not to be started without flow of water.
i)
The thermostat, reset button and/or Rheem IQ
TM
controller are set.