67
The factory setting for this switch should all be in the
OFF position (DOWN).
Change the first switch on “DIP 2” to the ON position
(UP). Performance mode is selected.
To select Energy Saver mode, change the fourth switch on “DIP 1” to
the ON position (UP)�
Replace the front cover panel.
Turn on all electric power to the water heater.
Turn On the remote control. The pump and water heater
will turn on to raise recirculation loop temperature.
Recirculation Operation
The water heater is turned ON when the
recirculation pump starts operation. The water heater
produces hot water at the setting temperature. When
the return water temperature reaches approximately
15°F below the setting temperature, the water heater
and the pump will turn OFF. The cycle will restart
at the approximate time interval in the table below
based on the temperature thermistor readings.
Energy Saver Mode
The Energy Saver mode operates as follows:
• Less energy consumption due to fewer pump cycles
• Pump cycles ON every 30 to 69 minutes
Performance Mode
The Performance mode operates as follows:
• Higher energy consumption due to more pump
cycles
• Pump cycles ON every 15 to 35 minutes
Setting Temp
Typical Pump ON Intervals [Min]
[°F]
Performance
Energy Saver
140
15
30
135
15
30
130
15
30
125
15
30
120
16
31
118
17
33
116
18
35
114
19
38
112
20
40
110
22
44
108
24
47
106
26
51
104
28
56
102
31
62
100
35
69
Actual pump ON intervals may vary based on the
setting temperature, insulation, and heat loss in the
system.
INSTALLATION INSTRUCTIONS
Recirculation Control (cont.)
10
9
11
12
8
As set
from factory
MIN
MAX
ADJ
Recir
culating Pump