GENERAL DATA - RSNM
NOMINAL SIZES 2-5 TONS [7-17.6 kW]
Model RSNM- Series
A060CK
A060JK
Cooling Performance
1
Gross Cooling Capacity Btu [kW]
63,000 [18.46]
63,000 [18.46]
EER/SEER
2
11.3/13
11.3/13
Nominal CFM/ARI Rated CFM [L/s]
2000/1900 [944/897]
2000/1900 [944/897]
ARI Net Cooling Capacity Btu [kW]
60,000 [17.58]
60,000 [17.58]
Net Sensible Capacity Btu [kW]
45,000 [13.18]
45,000 [13.18]
Net Latent Capacity Btu [kW]
15,000 [4.4]
15,000 [4.4]
Net System Power kW
5.31
5.31
Compressor
No./Type
1/Copeland Scroll
1/Copeland Scroll
Outdoor Sound Rating (dB)
78
78
Outdoor Coil - Fin Type
Louvered
Louvered
Tube Type
Rifled
Rifled
Tube Size in. [mm] OD
0.375 [9.5]
0.375 [9.5]
Face Area sq. ft. [sq. m]
16.54 [1.54]
16.54 [1.54]
Rows / FPI [FPcm]
2 / 22 [9]
2 / 22 [9]
Indoor Coil - Fin Type
Louvered
Louvered
Tube Type
Rifled
Rifled
Tube Size in. [mm]
0.375 [9.5]
0.375 [9.5]
Face Area sq. ft. [sq. m]
5.78 [0.54]
5.78 [0.54]
Rows / FPI [FPcm]
4 / 13 [5]
4 / 13 [5]
Refrigerant Control
TX Valves
TX Valves
Drain Connection No./Size in. [mm]
1/1 [25.4]
1/1 [25.4]
Outdoor Fan - Type
Propeller
Propeller
No. Used/Diameter in. [mm]
1/24 [609.6]
1/24 [609.6]
Drive Type/No. Speeds
Direct/1
Direct/1
CFM [L/s]
4000 [1888]
4000 [1888]
No. Motors/HP
1 at 1/3 HP
1 at 1/3 HP
Motor RPM
1075
1075
Indoor Fan - Type
FC Centrifugal
FC Centrifugal
No. Used/Diameter in. [mm]
1/11x9 [279.4x228.6]
1/11x9 [279.4x228.6]
Drive Type/No. Speeds
Direct/2
Direct/2
No. Motors
1
1
Motor HP
3/4
3/4
Motor RPM
1075
1075
Motor Frame Size
48
48
Filter - Type
Field Supplied
Field Supplied
Furnished
No
No
(NO.) Size Recommended in. [mm x mm x mm]
(1)1x24x24 [25x610x610] (1)1x24x24 [25x610x610]
178 [5046]
178 [5046]
Weights
Net Weight lbs. [kg]
364 [165]
364 [165]
Ship Weight lbs. [kg]
390 [177]
390 [177]
3
4
Refrigerant Charge Oz. [g] (R-410A)
[
] Designates Metric Conversions
NOTES:
1. Cooling Performance is rated at 95°F ambient, 80°F entering dry bulb, 67°F entering wet bulb. Gross capacity does not include the effect of fan motor
heat. ARI capacity is net and includes the effect of fan motor heat. Units are suitable for operation to ±20% of nominal cfm. Units are certified in
accordance with the Unitary Air Conditioner Equipment certification program, which is based on ARI Standard 210/240 or 360.
2. EER and/or SEER are rated at ARI conditions and in accordance with DOE test procedures.
3. Outdoor Sound Rating shown is tested in accordance with ARI Standard 270.
4. Standard 3/4” PVC P-Trap provided.
Summary of Contents for RSNM SERIES
Page 31: ...31 FIGURE 7 WIRING DIAGRAM RSNM...
Page 32: ...32 FIGURE 8 WIRING DIAGRAM RSNM...
Page 33: ...33 FIGURE 9 WIRING DIAGRAM RSPM WITH X 13 BLOWER MOTOR...
Page 34: ...34 FIGURE 10 WIRING DIAGRAM RSPM WITH X 13 BLOWER MOTOR...
Page 35: ...35 FIGURE 11 2 TON AIR CHARGING CHART...
Page 36: ...36 FIGURE 12 2 5 TON AIR CHARGING CHART...
Page 37: ...37 FIGURE 13 3 0 TON CHARGING CHART...
Page 38: ...38 FIGURE 14 3 5 TON CHARGING CHART...
Page 39: ...39 FIGURE 15 4 0 TON CHARGING CHART...
Page 42: ...42...
Page 43: ...43...
Page 44: ...44 CM 0408...