12
D. INTERNAL WIRING
1. A diagram of the internal wiring of this unit is located on the electrical control box
cover. If any of the original wire as supplied with the appliance must be replaced,
the wire gauge and insulation must be the same as original wiring.
E. GROUNDING
F. THERMOSTAT
Mount the thermostat on an inside wall about five feet above the floor in a location
where it will not be affected by unconditioned air, sun, or drafts from open doors or
other sources. READ installation instructions in air conditioner thermostat package
CAREFULLY because each has some different wiring requirements.
XI. INDOOR AIR FLOW DATA
All 208/230 volt units are equipped with multi-speed indoor blower motors. Each unit is
shipped factory wired for the proper speed at a normal external static. See Airflow
Performance Table for blower performance.
FIGURE 5
HEATER KIT INSTALLATION
RECOMMENDED
WIRING
HEATER
KIT
WIRING
HEATER
ELEMENTS
!
WARNING
THE UNIT MUST BE PERMANENTLY GROUNDED. A GROUNDING LUG IS
PROVIDED. FAILURE TO GROUND THIS UNIT CAN RESULT IN FIRE OR ELEC-
TRICAL SHOCK CAUSING PROPERTY DAMAGE, SEVERE PERSONAL INJURY
OR DEATH.
Summary of Contents for RSNM SERIES
Page 31: ...31 FIGURE 7 WIRING DIAGRAM RSNM...
Page 32: ...32 FIGURE 8 WIRING DIAGRAM RSNM...
Page 33: ...33 FIGURE 9 WIRING DIAGRAM RSPM WITH X 13 BLOWER MOTOR...
Page 34: ...34 FIGURE 10 WIRING DIAGRAM RSPM WITH X 13 BLOWER MOTOR...
Page 35: ...35 FIGURE 11 2 TON AIR CHARGING CHART...
Page 36: ...36 FIGURE 12 2 5 TON AIR CHARGING CHART...
Page 37: ...37 FIGURE 13 3 0 TON CHARGING CHART...
Page 38: ...38 FIGURE 14 3 5 TON CHARGING CHART...
Page 39: ...39 FIGURE 15 4 0 TON CHARGING CHART...
Page 42: ...42...
Page 43: ...43...
Page 44: ...44 CM 0408...