background image

Air

Model Number Identification

R96V Series

5

Model Number Identification

R

96

V

A

040

2

3

17

M

S

A

Rheem 

96%

Efficient

Motor -

ECM

Design Series

A = 1st Design

Input

BTU/HR

040 = 42,000   [12.31 kW]
060 = 56,000   [16.41 kW]
070 = 70,000   [20.51 kW]
085 = 84,000   [24.62 kW]
100 = 98,000   [28.72 kW]
115 = 112,000 [32.82 kW]

Stage - Two

Airflow

3 - Up to 3 Tons
5 - Up to 5 Tons

Cabinet Width

17 = 17.5"
21 = 21.0"
24 = 24.5"

Configuration - 

Multi-Position

S = Standard

N = NO

x

Revision -
Marketing

(A - First Time

Release)
(B - First

Revision)

[    ] Designates Metric Conversions

Summary of Contents for Prestige R96V series

Page 1: ...ble for improved serviceability Aluminized steel primary and stainless steel secondary con struction provide maximum corrosion resistance and thermal fatigue reliability Low profile 34 inch cabinet id...

Page 2: ...f Contents R96V Series 2 TABLE OF CONTENTS Standard Optional Equipment 3 Physical Data Specifications 4 Model Number Identification 5 Dimensional Data 6 Blower Performance Data 7 Accessories 8 Limited...

Page 3: ...ing applica tions transformer direct drive variable speed electrically commutated blower motor ECM Solid bottom Please note a thermostat is not included as standard equipment OPTIONAL EQUIPMENT Side a...

Page 4: ...LOAD AMPS 8 9 8 9 8 9 10 8 10 8 10 8 MINIMUM EXT STATIC PRESSURE IN W C kPa 18 045 20 050 23 057 28 070 28 070 28 070 MAXIMUM EXT STATIC PRESSURE IN W C kPa 1 0 0 249 1 0 0 249 1 0 0 249 1 0 0 249 1 0...

Page 5: ...n Input BTU HR 040 42 000 12 31 kW 060 56 000 16 41 kW 070 70 000 20 51 kW 085 84 000 24 62 kW 100 98 000 28 72 kW 115 112 000 32 82 kW Stage Two Airflow 3 Up to 3 Tons 5 Up to 5 Tons Cabinet Width 17...

Page 6: ...7 64 413 1613 64 412 085 0 0 0 1 25 2 51 0 147 5 67 21 533 1949 64 502 1945 64 500 100 0 0 0 1 25 2 51 0 152 69 21 533 1949 64 502 1945 64 500 115 0 0 0 1 25 2 51 0 165 75 241 2 662 2317 64 591 2313 6...

Page 7: ...14 ON 1040 1210 1050 1775 1800 1400 491 571 496 838 850 661 SW 13 ON SW 14 ON 607 660 700 925 1210 960 286 311 330 437 571 453 TARGET COOLING HEAT PUMP AIRFLOW HIGH COOLING CFM L s SW 4 OFF SW 5 OFF...

Page 8: ...Concentric Vent Termination Kit 2 Pipe US Canadian RXGY E03 Vertical Horizontal Concentric Vent Termination Kit 3 Pipe US Only RXGY E03A Vertical Horizontal Concentric Vent Termination Kit 3 Pipe US C...

Page 9: ...d stated in accordance with the terms of the limited warranty For complete details of the Limited and Conditional Warranties including applicable terms and conditions contact your local contractor or...

Page 10: ...Air Notes R96V Series 10...

Page 11: ...Air Notes R96V Series 11...

Page 12: ...ith Arkansas 72917 www rheem com In keeping with its policy of continuous progress and product improvement Rheem reserves the right to make changes without notice PRINTED IN U S A 10 14 QG FORM NO G11...