Air
Physical Data & Specifications
R96V Series
4
Physical Data and Specifications—Upflow Models
U.S. and Canadian Models
MODEL NUMBERS
R96VA0402317MSA R96VA0602317MSA R96VA0702317MSA R96VA0852521MSB R96VA1002521MSA R96VA1152524MSA
HIGH FIRE INPUT BTU/HR [kW]
➀
42,000 [12.31]
56,000 [16.41]
70,000 [20.50]
84,000 [24.61]
98,000 [28.72]
112,000 [32.82]
LOW FIRE INPUT
29,400 [8.61]
39,200 [11.49]
49,000 [14.36]
58,800 [17.23]
68,600 [20.11]
78,400 [23.00]
HEATING CAPACITY BTU/HR [kW]
40,320 [11.82]
53,760 [15.75]
67,200 [19.68]
80,640 [23.63]
94,080 [27.57]
107,520 [31.51]
HIGH ALTITUDE OUTPUT
10% DERATE [kW]
➁
36,288 [10.64]
48,384 [14.18]
60,480 [17.72]
72,756 [21.27]
84,672 [24.81]
96,768 [28.36]
BLOWER (D x W)
[mm]
11 x 7
[279 x 178]
11 x 8
[279 x 203]
11 x 8
[279 x 203]
11 x 10
[279 x 254]
11 x 10
[279 x 254]
11 x 11
[279 x 279]
MOTOR H.P. [W]–
TYPE
1/2 [373] E.C.M.
1/2 [373] E.C.M.
1/2 [373] E.C.M.
3/4 [559] E.C.M.
3/4 [559] E.C.M.
3/4 [559] E.C.M.
MOTOR FULL LOAD AMPS
8.9
8.9
8.9
10.8
10.8
10.8
MINIMUM EXT. STATIC PRESSURE
(IN. W.C.) [kPa]
.18 [.045]
.20 [.050]
.23 [.057]
.28 [.070]
.28 [.070]
.28 [.070]
MAXIMUM EXT. STATIC PRESSURE
(IN. W.C.) [kPa]
1.0 [0.249]
1.0 [0.249]
1.0 [0.249]
1.0 [0.249]
1.0 [0.249]
1.0 [0.249]
HEATING CFM @ .2" [.049 kPa]
W.C. E.S.P. [L/s]
1050 [496]
1025 [484]
1015 [479]
1470 [694]
1710 [807]
1450 [684]
COOLING CFM @ .5" [.124 kPa]
W.C. E.S.P. [L/s]
1050 [496]
1050 [496]
1050 [496]
1750 [826]
1750 [826]
1750 [826]
TEMPERATURE RISE-HIGH FIRE
RANGE IN DEGREES °F [°C]
20 - 50
[11 - 28]
30 - 60
[17 - 33]
40 - 70
[22 - 39]
30 - 60
[17 - 33]
40 - 70
[22 - 39]
45 - 75
[25 - 42]
TEMPERATURE RISE-LOW FIRE
RANGE IN DEGREES °F [°C]
15 - 45
[8 - 25]
20 - 50
[11 - 28]
30 - 60
[17 - 33]
20 - 50
[11 - 28]
30 - 60
[17 - 33]
35 - 63
[19 - 36]
APPROX. SHIPPING WEIGHT
(LBS.) [kg]
128 [58]
128 [58]
132 [60]
147.5 [67]
152 [69]
165 [75]
AFUE
➂
96.00%
96.00%
96.00%
96.00%
96.00%
96.00%
NOTES: All models are 115V, 60HZ, 1 phase Gas connection size for all models is
1
/
2
" [13 mm] N.P.T.
➀
Installation instructions for high altitude derate.
➁
Canadian installations only.
➂
In accordance with D.O.E. test procedures.
*S=Standard Models
NOTE: Standard model complies with California low nox requirements.
[ ] Designates Metric Conversions
Summary of Contents for Prestige R96V series
Page 10: ...Air Notes R96V Series 10...
Page 11: ...Air Notes R96V Series 11...