HEAT PUMP AND TANK ASSEMBLY
23
ASSEMBLY PROCEDURE
Warning:
The heat pump must be assembled, plumbed and filled with water prior to power being
connected and switched on.
The following procedure should be followed to properly place the heat pump module in position and connect
to the storage tank:
1.
Remove all packaging and position the storage tank in its intended location.
The storage tank must be positioned at least 100 mm from the wall. If a minimum clearance of 100 mm
is not allowed for, the heat pump module will not be able to be completely connected to the storage tank.
The water connections may be on either the left or right hand side, parallel to the wall.
1631
1317
1018
32°
574
HOT
OUTLET
COLD
INLET
114
546
871
863
619
245
100
WALL
AIR
INLET
AIR INLET
638
AIR
OUTLET
300
MI
N
VENTILATION
CLEARANCE
CONDENSATE DRAIN
TPR
VALVE
AIR INLET
AIR
OUTLET
300 MIN
162
HEAT PUMP DIMENSIONS - 325L
SK6499 A4
REV BD 5/08
300
MI
N
ELECTRICAL
CONNECTION
VENTILATION
CLEARANCE
Step 1
position storage tank at least 100 mm from the wall
2.
Remove the two screws securing the lower front cover to the storage tank.
Remove the lower front cover from the storage tank.
Step 2
Step 3
remove screws
withdraw the power cable
from lower front cover
and tank sensor cable
3.
Withdraw the power cable and tank sensor cable, housed behind the lower front cover, from the
opening.