For  rear  entry  connection  on  3-10  Litre 
models,  we  recommend  that  you  use  a 
braided flexible hose with a 90  elbow for 
ease of connection. 

 

F.  OVERFLOW / VENT

 

 

CONNECTION IMPORTANCE

 

Connect  a  15  mm  (½”)  pipe  to  the 
overflow/vent  connection  (½”BSP  nipple). 
This pipe is to be made of a material such 
that  continuous  steam  will  not  degrade  it 
(i.e.  copper).  This  pipe  must  have  a 
continuous fall, not exceeding 3 metres in 
length  and  /  or  contain  no  more  than  4 
bends (refer to figure 2).  

 

 

Figure 1: Water Connection 

 
 

 
 
 
 
 
 

 

 

 

If the site situation requires a pipe length 
exceeding  3  metres,  then  discharge  the 
overflow/drain into a tundish. 
The  drain  pipe  work  must  not  exert  a 
pressure of more than 1 metre of head on 
the Lazer boiling unit (refer to figure 2).  

 

During normal operation of the Lazer, the 
overflow/vent  connection  may  discharge 
small 

quantities 

of 

steam 

and 

condensate, so it  is  ESSENTIAL  that  the 
drain pipe is attached to the overflow vent 
connection. 

This 

drain 

pipe 

must 

discharge  to  waste  at  a  point  where  no 
scald  injury,  nuisance  nor  inconvenience 
is  caused  to  people  in  the  immediate 
vicinity. 

 

WARNINGS:  

Ensure  the  overflow/vent  line  remains 
open 

because  the  Lazer’s  tank  is  not 

designed  to  be  pressurised.  Where 
freezing may occur, protect the pipes and 
install an air break. It is recommended to 
install  an  air  break  in  the  overflow/vent 
drain line, no more than 300 mm from the 
Lazer unit. Also it is important to connect 
the 

overflow/vent 

and 

water 

inlet 

correctly.  Incorrect  connection  of  pipe 
work may damage the unit. 

G. DRAIN  

WARNING:  

Before draining the unit, ensure 
the appliance has been switched 
off, and water is not hot enough to 
scald. 
To  drain  3-10L  models,  turn  unit  off  and 
open  tap  until  no  water  flows  out. 
Remove  unit  from  wall  and  tip  over  with 
tap  open  until  unit  is  empty.  For  15-40L 
units.  A  drain plug  is accessible  from  the 
bottom  of  the  unit  (note  switch  unit  off 
before draining) 

IMPORTANT 

Installation and maintenance of the Lazer Boiling Water 

unit shall be carried out by a qualified service person. 

 

Your closest Rheem Service Centre can be contacted by 

telephoning 0800 657 335 

4. 

Summary of Contents for Lazer Classic Series

Page 1: ...OWNERS GUIDE INSTALLATION INSTRUCTIONS CLASSIC SERIES POWDER COATED Models 3 5 7 5 10 15 25 40 Litre STAINLESS STEEL Models 7 5 10 15 25 40 Litre IMPORTANT PLEASE LEAVE WITH THE OWNER Part No 316935A...

Page 2: ...ap Outlet 5 J Electrical Requirements 5 4 OPERATION 5 MOUNTING DIMENSION SPECIFICATION FOR ALL MODELS drawing 6 DIMENSION SPECIFICATION FOR ALL MODELS drawing 7 5 FOR UNITS WITH A TIMER 8 A Setting Th...

Page 3: ...te on the left hand side C MINIMUM CLEARANCES For ventilation reasons all units require a minimum clearance of 50mm on all sides For ease of servicing where there is sufficient space we recommend 300m...

Page 4: ...ipe must discharge to waste at a point where no scald injury nuisance nor inconvenience is caused to people in the immediate vicinity WARNINGS Ensure the overflow vent line remains open because the La...

Page 5: ...of the power supply must be incorporated during installation in accordance with the wiring rules 4 OPERATION When the installation is complete first turn on the water supply before switching on the po...

Page 6: ...334 334 490 490 490 B mm 143 176 176 176 180 235 325 C mm 400 430 515 615 615 615 615 D mm 234 267 267 267 271 326 416 E mm 15 15 15 15 8 8 8 F mm 50 50 50 50 32 32 32 G mm 53 53 53 53 103 103 103 H m...

Page 7: ...50 75 75 100 Maximum Water Pressure kPa 1000 1000 1000 1000 1000 1000 1000 Element Size kW 1 8 2 4 2 4 2 4 2 4 3 6 4 6 Classic Models Dimension 3 Litre 5 Litre 7 5 Litre 10 Litre 15 Litre 25 Litre 40...

Page 8: ...Shows STD Pressing the UP button alternates the STD AUTO icons STD operation means that the unit operates 24 hours a day Auto mode reverts the unit to operate at the pre set times on the timer Press t...

Page 9: ...Press the Accept button to confirm selection and the display reverts to the Filter menu F To Service Menu Select Appropriate Service Mode i Error Codes ii Boiling Temp iii Chiller Temp iv Calib Reset...

Page 10: ...it to help determine the life of any filter attached to the unit To reset the filter the operator only has to push the Filter Reset button for 10 seconds C Power LED Red The red Power LED shows that t...

Page 11: ...heating element is properly wired then check its resistance Replace if broken Electronic Controller failure Test the electronic controller Thermistor failure Replace the thermistor 3 The unit boils co...

Page 12: ...the installed site will be for the account of the owner 4 The Warranty only applies to the Boiling Water Unit and therefore does not cover any plumbing or electrical parts supplied by the installer a...

Reviews: