**It is strongly recommended that any REMEDY be carried out by a qualified service person** 

SYMPTOMS 

POSSIBLE CAUSE 

REMEDY 

 

 

 

 

1. 

The unit does not fill with 
water 

There is no power supply 

Check the electrical supply. 

There is no water supply 

Check the water supply. 

The inlet strainer is 
blocked 

Check the Inlet Strainer, clean or 
replace. 

Electronic Controller 
failure 

Test the electronic controller. 

Solenoid Valve failure 

Check resistance of the solenoid, 
replace if broken. 

The Filter is blocked (If 
unit is supplied with an 
inlet water filter) 

Check the filter, replace if blocked 
(see section 5E for re setting the 
filter) 

 

 

 

 

2.

 

The unit fills water to low 
level and does not heat 

Thermal cut-out has 
tripped 

Reset the thermal cut-out. 

Heating element failure 

If the heating element is properly 
wired, then check its resistance. 
Replace if broken. 

Electronic Controller 
failure 

Test the electronic controller. 

Thermistor failure 

Replace the thermistor. 

 

 

 

 

3. 

The unit boils 
continuously 

Low Air Pressure 

Recalibrate the unit (see section 5F 
sub section v) for how to recalibrate 
the unit 

Electronic Controller 
failure 

Test the electronic controller. 

Thermistor failure 

Replace the thermistor. 

 

 

 

 

4. 

The unit overflows 

Incoming water pressure 
is too high 

Reduce incoming water pressure. 

Solenoid valve failure 

Turn the unit off. If water still 
overflows, replace the solenoid valve. 

Level probe failure 

Clean the level probe 
Replace the level probe 

 

 

 

 

5. 

There is no water from 
the tap 

The unit did not fill with 
enough water 

See 1. & 2. above. 

The tap diaphragm is 
disconnected from its 
spindle 

Drain water out of the unit  
(see paragraph 6 on page 4). 
When unit is empty, disassemble and 
repair the tap. 

 

 

 

 

 LAZER BOILING WATER UNIT: FAULT FINDING GUIDE

.

 

11. 

Summary of Contents for Lazer Classic Series

Page 1: ...OWNERS GUIDE INSTALLATION INSTRUCTIONS CLASSIC SERIES POWDER COATED Models 3 5 7 5 10 15 25 40 Litre STAINLESS STEEL Models 7 5 10 15 25 40 Litre IMPORTANT PLEASE LEAVE WITH THE OWNER Part No 316935A...

Page 2: ...ap Outlet 5 J Electrical Requirements 5 4 OPERATION 5 MOUNTING DIMENSION SPECIFICATION FOR ALL MODELS drawing 6 DIMENSION SPECIFICATION FOR ALL MODELS drawing 7 5 FOR UNITS WITH A TIMER 8 A Setting Th...

Page 3: ...te on the left hand side C MINIMUM CLEARANCES For ventilation reasons all units require a minimum clearance of 50mm on all sides For ease of servicing where there is sufficient space we recommend 300m...

Page 4: ...ipe must discharge to waste at a point where no scald injury nuisance nor inconvenience is caused to people in the immediate vicinity WARNINGS Ensure the overflow vent line remains open because the La...

Page 5: ...of the power supply must be incorporated during installation in accordance with the wiring rules 4 OPERATION When the installation is complete first turn on the water supply before switching on the po...

Page 6: ...334 334 490 490 490 B mm 143 176 176 176 180 235 325 C mm 400 430 515 615 615 615 615 D mm 234 267 267 267 271 326 416 E mm 15 15 15 15 8 8 8 F mm 50 50 50 50 32 32 32 G mm 53 53 53 53 103 103 103 H m...

Page 7: ...50 75 75 100 Maximum Water Pressure kPa 1000 1000 1000 1000 1000 1000 1000 Element Size kW 1 8 2 4 2 4 2 4 2 4 3 6 4 6 Classic Models Dimension 3 Litre 5 Litre 7 5 Litre 10 Litre 15 Litre 25 Litre 40...

Page 8: ...Shows STD Pressing the UP button alternates the STD AUTO icons STD operation means that the unit operates 24 hours a day Auto mode reverts the unit to operate at the pre set times on the timer Press t...

Page 9: ...Press the Accept button to confirm selection and the display reverts to the Filter menu F To Service Menu Select Appropriate Service Mode i Error Codes ii Boiling Temp iii Chiller Temp iv Calib Reset...

Page 10: ...it to help determine the life of any filter attached to the unit To reset the filter the operator only has to push the Filter Reset button for 10 seconds C Power LED Red The red Power LED shows that t...

Page 11: ...heating element is properly wired then check its resistance Replace if broken Electronic Controller failure Test the electronic controller Thermistor failure Replace the thermistor 3 The unit boils co...

Page 12: ...the installed site will be for the account of the owner 4 The Warranty only applies to the Boiling Water Unit and therefore does not cover any plumbing or electrical parts supplied by the installer a...

Reviews: