background image

2

Rheem Heating, Cooling and Water Heating

STANDARD EQUIPMENT

Completely assembled and wired; 2 speed induced draft blower; high and low
pressure switches; 2 stage redundant main gas control; blower compartment
door safety switch; solid state time on/time off blower control; limit control;
transformer; direct drive multi-speed blower motor. Furnaces are equipped 
with cooling/heating relay and transformer (40VA) ready for air conditioning
applications. (Please note: a thermostat is not included as standard equipment.)
Flame sensor diagnostics; fused-protection (secondary).

NOTE: Furnace is not listed for use with fuels other than natural or L.P. 

(propane) gas.

The complete terms of limited and other warranties are available at our
sales office, or through local installer.

All models can be converted by a qualified Rheem professional or local service
dealer to use L.P. (propane) gas without changing burners. Factory approved
kits must be used to convert from natural to L.P. (propane) gas and may be
ordered as optional accessories.

For L.P. (propane) operation, refer to Conversion Kit Index Form.

NOTE: For natural and L.P. (propane) gas models, direct spark ignition is 100%

lockout type.

WARNING

THIS FURNACE IS NOT APPROVED

OR RECOMMENDED

FOR USE IN MOBILE HOMES

Integrated
Furnace Control

Heat Exchanger

In-Shot Burners

Direct Spark Ignitor

CLASSIC

®

PLUS SUPER QUIET 80

TWO STAGE 
DOWNFLOW GAS FURNACE

Remote Sensor

Two-Speed Draft 
Inducer Motor

Summary of Contents for Classic Plus 05EAUER

Page 1: ...with humidifier and electronic air cleaner hookups Insulated blower compartment a two stage gas valve and a specially designed two speed draft inducer motor make it one of the quietest furnaces on the...

Page 2: ...er than natural or L P propane gas The complete terms of limited and other warranties are available at our sales office or through local installer All models can be converted by a qualified Rheem prof...

Page 3: ...Temperature Rise Range F C High Input 25 55 13 9 30 6 35 65 19 4 36 1 Max Outlet Air Temp F C 155 68 3 165 78 3 Approx Shipping Weight Lbs kg 85 39 105 48 AFUE 80 0 80 0 Low Input BTU Hr kW 35 000 10...

Page 4: ...NCE TO COMBUSTIBLE MATERIAL INCHES mm MODEL RGLQ A B C D E REDUCED CLEARANCES IN mm 05 14 356 1227 32 326 103 8 264 131 8 333 0 4 102 0 1 25 3 76 6 152 LEFT SIDE RIGHT SIDE BACK TOP FRONT VENT SHIP WG...

Page 5: ...979 2340 1104 1230 580 1620 765 2035 960 2290 1081 1205 569 1570 741 1990 939 2215 1045 1170 552 1545 729 1955 923 2145 1012 1115 526 1485 701 1900 897 2080 982 12 ARJR 11 x 10 279 x 254 3 4 559 LOW...

Page 6: ...RGLQ 05 RXGC B17 18 457 163 4 425 RGLQ 07 RGLQ 10 A RXGC B21 211 2 546 201 4 514 RGLQ 10 B C IN mm 213 4 552 111 4 286 143 4 451 181 4 464 FOR HIGH ALTITUDES HIGH ALTITUDE CONVERSION See Installation...

Page 7: ...Rheem Heating Cooling and Water Heating 7 NOTES...

Page 8: ...ate Provincial and Local codes regulations and practices Rheem Heating Cooling and Water Heating P O Box 17010 Fort Smith AR 72917 In keeping with its policy of continuous progress and product improve...