background image

Rheem Heating, Cooling and Water Heating

5

MODEL

NUMBER

RGLQ-

SERIES

BLOWER

SIZE

[mm]

MOTOR

H.P.

[W]

BLOWER

SPEED

CFM [L/s] AIR DELIVERY

EXTERNAL STATIC PRESSURE INCHES [kPa] WATER COLUMN

.1 [.02]

.2 [.05]

.3 [.07]

.4 [.10]

.5 [.12]

.6 [.15]

.7 [.17]

05*AUER

11 x 6

[279 x 152]

1/2

[373]

LOW

MED-LO

MED-HI

HIGH

655 [309]
975 [460]
180 [557]

1335 [630]

630 [297]
943 [445]

1140 [538]
1290 [608]

600 [283]
915 [432]

1105 [521]
1250 [590]

565 [266]
886 [418]

1067 [503]
1202 [567]

532 [251]
852 [402]

1027 [484]
1157 [546]

500 [236]
813 [383]
980 [462]

1110 [524]

467 [220]
770 [363]
924 [436]

1060 [500]

07*AMER

11 x 7

[279 x 178]

1/2

[373]

LOW 

MED-LO

MED-HI

HIGH

910 [429]

1074 [507]
1229 [580]
1409 [665]

887 [418]

1054 [497]
1207 [569]
1385 [653]

863 [407]

1034 [488]
1184 [558]
1361 [642]

839 [396]

1007 [475]
1159 [547]
1329 [627]

814 [384]
979 [462]

1134 [535]
1297 [612]

776 [366]
944 [455]

1099 [518]
1260 [594]

738 [348]
908 [428]

1063 [501]
1223 [577]

10*BRJR

11 x 10

[279 x 254]

3/4

[559]

LOW

MED-LO

MED-HI

HIGH

1374 [648]
1709 [806]
2132 [1006]
2362 [1114]

1356 [640]
1686 [795]
2085 [984]
2300 [1085]

1339 [632]
1663 [784]
2038 [961]
2237 [1055]

1323 [624]
1635 [771]
1988 [938]
2173 [1025]

1286 [607]
1607 [758]
1937 [914]
2108 [994]

1249 [589]
1562 [737]
1882 [888]
2036 [960]

LOW

895 [422]

874 [412]

852 [402]

825 [389]

798 [376]

766 [362]

734 [346]

1212 [572]
1516 [715]
1827 [862]
1964 [926]

15*ARJR

11 x 10

[279 x 254]

3/4

[559]

LOW

MED-LO

MED-HI

HIGH

1300 [614]
1675 [791]
2105 [993]

1280 [604]
1650 [779]
2075 [979]
2340 [1104]

1230 [580]
1620 [765]
2035 [960]
2290 [1081]

1205 [569]
1570 [741]
1990 [939]
2215 [1045]

1170 [552]
1545 [729]
1955 [923]
2145 [1012]

1115 [526]
1485 [701]
1900 [897]
2080 [982]

12*ARJR

11 x 10

[279 x 254]

3/4

[559]

LOW

MED-LO

MED-HI

HIGH

1315 [620]
1618 [763]
2065 [974]
2275 [1074]

1292 [609]
1597 [753]
2025 [956]
2219 [1047]

1269 [599]
1576 [743]
1984 [936]
2163 [1021]

1250 [590]
1552 [732]
1938 [915]
2103 [992]

1231 [581]
1528 [721]
1891 [892]
2042 [964]

1194 [563]
1486 [701]
1824 [861]
1982 [935]

1157 [546]
1443 [681]
1756 [829]
1921 [907]

1030 [486]
1425 [673]
1815 [857]
1995 [942]

10*AMER

11 x 7

[279 x 178]

1/2

[373]

MED-LO

MED-HI

HIGH

1052 [496]
1238 [584]
1383 [652]

1033 [487]
1217 [574]
1366 [644]

1013 [478]
1196 [564]
1348 [636]

991 [467]

1169 [551]
1317 [621]

968 [457]

1143 [539]
1286 [607]

930 [439]

1094 [516]
1245 [587]

891 [420]

1044 [492]
1203 [567]

NOTES: 

➀ 

Not to be used as a low stage heating speed.

Data compiled with factory filters installed.
See Form Number C11-211 for “N” Coil Data.
Factory rated to 0.5" W.C.
*E = Standard

*

N = NOx Models

[

] Designates Metric Conversions

GENERAL TERMS OF LIMITED WARRANTY

Rheem will furnish a replacement for any part of this product
which fails in normal use and service within the applicable
period stated, in accordance with the terms of the limited 
warranty.

*For Complete Details of the Limited Warranty, Including Applicable

Terms and Conditions, See Your Local Installer or Contact the 
Manufacturer for a Copy.

Gas Heat Exchanger Limited Warranty .........Limited Lifetime
Conditional Parts* (Registration Required) ......Ten (10) Years

BLOWER PERFORMANCE DATA—DOWNFLOW MODELS

Summary of Contents for Classic Plus 05EAUER

Page 1: ...with humidifier and electronic air cleaner hookups Insulated blower compartment a two stage gas valve and a specially designed two speed draft inducer motor make it one of the quietest furnaces on the...

Page 2: ...er than natural or L P propane gas The complete terms of limited and other warranties are available at our sales office or through local installer All models can be converted by a qualified Rheem prof...

Page 3: ...Temperature Rise Range F C High Input 25 55 13 9 30 6 35 65 19 4 36 1 Max Outlet Air Temp F C 155 68 3 165 78 3 Approx Shipping Weight Lbs kg 85 39 105 48 AFUE 80 0 80 0 Low Input BTU Hr kW 35 000 10...

Page 4: ...NCE TO COMBUSTIBLE MATERIAL INCHES mm MODEL RGLQ A B C D E REDUCED CLEARANCES IN mm 05 14 356 1227 32 326 103 8 264 131 8 333 0 4 102 0 1 25 3 76 6 152 LEFT SIDE RIGHT SIDE BACK TOP FRONT VENT SHIP WG...

Page 5: ...979 2340 1104 1230 580 1620 765 2035 960 2290 1081 1205 569 1570 741 1990 939 2215 1045 1170 552 1545 729 1955 923 2145 1012 1115 526 1485 701 1900 897 2080 982 12 ARJR 11 x 10 279 x 254 3 4 559 LOW...

Page 6: ...RGLQ 05 RXGC B17 18 457 163 4 425 RGLQ 07 RGLQ 10 A RXGC B21 211 2 546 201 4 514 RGLQ 10 B C IN mm 213 4 552 111 4 286 143 4 451 181 4 464 FOR HIGH ALTITUDES HIGH ALTITUDE CONVERSION See Installation...

Page 7: ...Rheem Heating Cooling and Water Heating 7 NOTES...

Page 8: ...ate Provincial and Local codes regulations and practices Rheem Heating Cooling and Water Heating P O Box 17010 Fort Smith AR 72917 In keeping with its policy of continuous progress and product improve...

Reviews: