Owner’s Guide 

and 

Installation Instructions 

 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

Rheem Guardian UV Disinfection 

 
 

 

 

 

This UV system must be installed and serviced by a qualified person. 

Please leave this guide with a responsible officer. 

Summary of Contents for 940001

Page 1: ...Owner s Guide and Installation Instructions Rheem Guardian UV Disinfection This UV system must be installed and serviced by a qualified person Please leave this guide with a responsible officer...

Page 2: ...TS CONTENTS 2 APPLICATIONS 3 GENERAL SAFETY INSTRUCTIONS 4 REACTORS 8 INSTALLATION CHECKLIST 9 ASSEMBLY 9 OPERATION 15 MAINTENANCE 16 SERVICE PROCEDURES 17 SPARE PARTS 20 RHEEM UV DISINFECTION WARRANT...

Page 3: ...cals or the need for extra processing to eliminate chemical odour taste or by products The disinfection efficiency of a UV system is determined by 1 the flow rate of water entering the UV reactor cham...

Page 4: ...been dropped or damaged in any way Make sure that the unit is unplugged when it is not being used prior to fitting or if removing any parts Do not remove the plug from the socket by pulling the electr...

Page 5: ...OW IF THE UV SYSTEM IS INSTALLED CORRECTLY Installation requirements are shown on pages 10 to 16 The UV system must be installed by a qualified person and in accordance with the installation instructi...

Page 6: ...Rheem warranty to apply Note Some water analysis reports may state the conductivity of the water rather than the level of total dissolved solids Conductivity measured in microsiemens per centimetre S...

Page 7: ...upply bore water supply desalinated water supply public reticulated water supply or water brought in from another supply then water chemistry information should be sought from the supplier or it shoul...

Page 8: ...and all local codes and regulatory authority requirements In New Zealand the installation must also conform with the New Zealand Building Code All packaging materials must be removed from the warm wa...

Page 9: ...ction process where the temperature exceeds 55 C ASSEMBLY The following is a basic guideline for assembly of these units ASSEMBLY OF THE REACTOR CHAMBER Prior to installation ensure the following The...

Page 10: ...BY PASS To facilitate continuing warm water supply whilst servicing the UV unit a warm water by pass should be installed prior to the isolating valve at the inlet and after the isolating valve at the...

Page 11: ...sealing nut so that it is seated in its groove on the threaded side of the nut Picture 3 3 Wipe the quartz thimble down with a clean soft cloth soaked in methylated spirits then dry it 4 Keep a firm...

Page 12: ...himble that is protruding from the chamber IMPORTANT NOTE Care should be taken during the next step due to the fragile nature of the quartz thimble Also note that the sealing nut should only be tighte...

Page 13: ...ld be taken to not leave any markings on the UV lamp Do not touch the lamp without protective gloves If the chamber is installed vertically NEVER drop the lamp into the quartz thimble as this may crac...

Page 14: ...tion power supply can output up to a 240V 2A voltage free signal to a BMS to indicate lamp run and or fail status Connecting between common C Normal Open NO indicates RUN status Connecting between com...

Page 15: ...it 2 Insert the power lead into the mains power source and switch on the power The UV lamp will ignite and come on however it will take between 2 and 5 minutes for the lamp to reach full output 3 The...

Page 16: ...rvice provides a comprehensive maintenance program structured to meet the most stringent requirements to maintain the product at peak performance and monitor for the presence of Legionella Contact you...

Page 17: ...aced and the unit reassembled as per the above procedure OR for cleaning or quartz thimble replacement continue as follows Quartz thimble and UV Lamp are Fragile Care must be taken when handling and i...

Page 18: ...ve the thread of the chamber It is important the thimble is correctly located in its support otherwise the thimble will be damaged when the sealing nut is tightened 13 Insert the quartz thimble closed...

Page 19: ...determined before proceeding 1 Switch OFF the mains power to the UV system 2 Open the power supply box and remove the fuse holder by pulling it from the fuse terminal block 3 Replace the fuse 11 FTB0...

Page 20: ...uartz Thimble 11 QT 090028 11 QT 121028 Ballast 11 EL BAL EC36 40 11 EL BAL 170 E Starter 11 EL START KUEFS600 N A Power Supply 11 U15000S76SS PS E170M 11 U4000 D 28 PSM40P2AM Relay 11 EL RELAY TLY2 2...

Page 21: ...sition that does not allow safe or ready access the cost of that access including the cost of additional materials handling and or safety equipment shall be the owner s responsibility In other words t...

Page 22: ...numbers or rating labels b Is not installed in Australia 5 HOW TO MAKE A CLAIM UNDER THIS WARRANTY 5 1 If you wish to make a claim under this warranty you need to a Contact Rheem on 131031 and provid...