INSTALLATION – WATER HEATER
43
DIMENSIONS AND TECHNICAL DATA
Model
884 024
886 024
Rated delivery
(@ 40°C rise)
litres / min
15.0
Recovery
(@ 25°C rise)
litres / min
24
Mass
Empty
kg
24
Gas Details
Hourly Gas
Consumption
(MJ)
Min Gas Pressure
(kPa)
Test Point Gas Pressure (kPa)
Max Gas Pressure
(kPa)
minimum maximum
Model
024 024 024 024 024
Natural 162 1.13 0.21 0.73 3.50
Propane 162 2.75 0.24 1.09 3.50
LPG 162
2.75
0.21
1.00
3.50
Model numbers: N = Natural, P = Propane (AU), L = LPG (NZ).
Letter N, P or L is included in the model number, e.g. 884024NF, to denote gas type.
F = Frost protection.
Z = New Zealand models, e.g. 884024NFZ, 884024LFZ