TEMPERATURE CONTROL – DELUXE
20
BATHROOM CONTROLLERS – DELUXE
The Bathroom Deluxe controller(s) allows the user to select the temperature setting for the hot water to be
used in the bathroom. They have a minimum temperature setting of 37°C and a maximum temperature
setting of:
•
884 series
50°C
•
886 series
50°C
The Bathroom Deluxe controllers operate in tandem. Whenever an operation is selected on one Bathroom
Deluxe controller, it is also set on the other Bathroom Deluxe controller. The Bathroom Deluxe controllers
automatically have priority (ACTIVE light glows) if they are on.
Important:
It is important to turn on the Bathroom Deluxe controller before opening a hot tap in the bathroom
(priority is gained automatically and the ACTIVE light glows). If the Bathroom Deluxe controller is not on and
the Kitchen Deluxe controller is on (will have priority and ACTIVE light glows), then it is possible to receive
water at a temperature higher than expected from a hot tap in the bathroom. This temperature could be up
to:
•
884 series
50°C if a temperature limiting device is installed in the hot pipe to the
bathroom or up to 60°C – AU or 55°C – NZ if a temperature limiting device is
not installed.
•
886 series
50°C
Notes on the Bathroom Deluxe controllers:
•
The Deluxe controller cannot be turned on whilst a hot tap is open.
•
When a Bathroom Deluxe controller is turned on, it gains priority (ACTIVE light glows) from the Kitchen
Deluxe controller.
•
The Bathroom Deluxe controller must be on in order to adjust the temperature setting on the Bathroom
Deluxe controller.
•
The Kitchen Deluxe controller can be turned off from a Bathroom Deluxe controller.
Press and hold the ON / OFF button on the Bathroom Deluxe controller for three seconds. This turns off
all the Deluxe controllers, including the bath fill function if it is on, the displays go blank and the lights go
out. If hot water is flowing from a hot tap, it will go cold.
•
Warning:
It is advised to leave the Bathroom Deluxe controller on after hot water usage is finished in
the bathroom.
Turning off a Bathroom Deluxe controller in one bathroom will also turn off the
Bathroom Deluxe controller in the other bathroom.
The Kitchen Deluxe controller will gain priority
(ACTIVE light glows) if it is on and the temperature setting can be up to:
884 series
60°C – AU
55°C – NZ
886 series
50°C
If a hot tap is open in another bathroom, the water will be delivered at up to 50°C for an 886 series
model, or up to 50°C for an 884 series model if a temperature limiting device is installed in the hot pipe
to the bathroom or up to 60°C – AU or 55°C – NZ if a temperature limiting device is not installed.
Rheem
BATH
(
l
)
4 0
°C
1 2 0
ACTIVE
ON/OFF
BATH
FILL
B1
BATH
FILL
VOLUME
BATH
FILL
TEMPERATURE
ACTIVE
Light
on
2.
Adjust
Temperature
3.
Open
hot
tap
4.
Hot
Water
Press
1.
ON/OFF
Bath
Water
Volume
Bath
Fill
Temp
Bath
Fill
Set
Bath
Fill
Water
Volume
and
Temperature
1.
2.
Bath
Fill
completed
(automatic)
Bath
Fill
Button
(Red
light
flashes)
6.
Close
hot
tap
5.
Press
Bath
Fill
Button
(Red
light
on)
3.
4.
Open
hot
tap
BATH
FILL
Press
Bath
Fill
Button
(R
ed
light
off)
7.
BATH
FILL
Bathroom Deluxe
Controller
front cover
closed
front cover
open