background image

8

TEMPERATURE CONTROL

FUNCTIONS OF ALL CONTROLLERS

If one or more controllers are installed, at least one must be on for the water heater
to operate. If all controllers are off, the water heater will only deliver cold water.

on/off

 button –

This button must be pressed once to turn on the controller. The

light in the button will glow when the controller is on. A controller

cannot be turned on if water is flowing from a hot tap. To turn off

a controller, press the on/off button once. The light will go out. A

controller can be turned off whilst water is flowing.

priority

 light –

This light will glow on a controller when that controller has priority.

Priority means that controller has control of the water heater

temperature setting. The water temperature setting can only be

adjusted by the controller that has priority.

in use

 light –

This light will glow on all controllers, whether they are on or off,

when hot water is flowing, regardless of which controller has

priority.

display panel

 –

The current temperature setting is displayed on all controllers

(whether hot water is flowing or not), when any controller is on. If

all controllers are off, then the display remains blank. The water

volume can also be displayed on the Kitchen controller.  The

x10

l

 

symbol glows when the water volume is displayed.

 (

up

 button) –

The up button increases the temperature setting (refer to

Temperature Adjustment on page 7).

 (

down

 button) –The down button decreases the temperature setting (refer to

Temperature Adjustment on page 7).

water volume

 button (Kitchen controller only) – This feature enables an alarm to

sound when a set volume of water has flowed through the water

heater (refer to Water Volume Function on page 12).

SILENCING A CONTROLLER

The controller emits a sound whenever a button is pressed. This sound can be

turned off to provide silent operation. To turn off the sound:

Press the on/off button, to deactivate the controller (on/off light is off).

Press and hold the up (

) button.

Press the on/off button, whilst the up (

) button is pressed.

The sound for the controller is deactivated. Repeat this procedure if you wish to

deactivate the sound on the other controllers. To restore the sound, repeat this

procedure.

Summary of Contents for 871 018

Page 1: ...1 Owners Guide and Installation Instructions This water heater must be installed and serviced by an authorised person Please leave this guide with the householder...

Page 2: ...of Rheem Australia Limited Southcorp Australia Pty Ltd or Paloma Industries Ltd Southcorp Water Heaters Australia is the supplier of the Rheem integrity range of electronic instantaneous gas water he...

Page 3: ...installer but may be of interest About your water heater 4 Temperature control 7 Save a service call 14 Installation Water heater 16 Dimensions 18 Connections Plumbing 19 Connections Electrical 19 Com...

Page 4: ...corp Water Heaters Australia or their Accredited Service Agent HOTTER WATER INCREASES THE RISK OF SCALD INJURY We recommend and it may also be required by regulations that an approved temperature limi...

Page 5: ...air inlet are not obstructed in any way at any time The water heater should be serviced annually by Southcorp Water Heaters Australia or their Accredited Service Agent Only genuine replacement parts s...

Page 6: ...ater Damage caused by freezing due to the unavailability of power at the water heater is not covered by warranty Pipe work to and from the water heater must be adequately insulated to prevent freezing...

Page 7: ...the preset outlet temperature Other manufacturers controllers cannot be installed with this water heater TEMPERATURE ADJUSTMENT A controller must be on and have priority to be able to adjust the temp...

Page 8: ...rrent temperature setting is displayed on all controllers whether hot water is flowing or not when any controller is on If all controllers are off then the display remains blank The water volume can a...

Page 9: ...9 TEMPERATURE CONTROL BATHROOM CONTROLLER KITCHEN CONTROLLER...

Page 10: ...ature Adjustment on page 7 The selected temperature setting will be displayed on all controllers 4 Open the hot tap The in use light will glow on all controllers 5 Close the hot tap The in use light w...

Page 11: ...up button or down button Refer to Temperature Adjustment on page 7 The selected temperature setting will be displayed on all controllers 3 Open the hot tap The in use light will glow on all controlle...

Page 12: ...e Each press of the up button or down button will change the water volume setting by 10 litres Pressing the up button or down button continuously will scroll the water volume setting Fifteen seconds a...

Page 13: ...ile water is being drawn press the water volume button After a few seconds the display returns to the temperature setting To turn off the water volume function before the alarm sounds press the water...

Page 14: ...lation valve in the gas line open Is there a gas supply to the rest of the house Try lighting another gas appliance Has the gas line been purged of air after installation Refer to your plumber WATER I...

Page 15: ...the cold water supply pipe to the water heater refer to Water Supply on page 17 HIGH GAS BILLS Is one outlet especially the shower using more hot water than you think Carefully review the family s ho...

Page 16: ...eater dimensions are shown on page 18 The installation must comply with these installation instructions and with the requirements of AS NZS 3500 4 AS 5601 AG 601 and any other statutory requirements I...

Page 17: ...e for installation in areas where the ambient temperature falls below 20 C including wind chill factor WATER SUPPLY Where the water supply pressure exceeds that shown below an approved pressure limiti...

Page 18: ...union PIPE INSULATION Adequate insulation is required on the cold and hot pipes to the underside of the water heater in frost prone areas refer to AS NZS 3500 GAS INLET The gas supply pipe is to be f...

Page 19: ...union must be fitted on the cold water supply pipe before the water heater refer to page 18 Do not fit a non return valve or stop cock The cold water supply pipe should be sized to ensure adequate flo...

Page 20: ...TANT CHECK the gas supply pressure at the inlet to the water heater with the water heater and all other gas burning appliances in the premises operating burners alight The minimum gas supply pressures...

Page 21: ...r an error code refer to Error Code on page 15 Maximum test point gas pressure Refer to the rating label on the water heater for the maximum test point gas pressure Follow Steps 1 to 7 above but open...

Page 22: ...available from Rheem Alternatively the cables may be extended using two core flex with a minimum cross sectional area of 0 5 mm2 No other manufacturers controllers are suitable for connection to this...

Page 23: ...cable to the two terminals on the back of the controller not polarity sensitive Ensure the connecting screws are seated tightly 7 Place the controller over the base plate Ensure the projections in the...

Page 24: ...and the water heater 3 Remove the base plate from the controller 4 Peel off one side of the adhesive paper from the foam packing and adhere to the back face of the base plate This is the side without...

Page 25: ...the cables into the cable notches Failure to do this may cause an unstable contact or even disconnection of the cables from the terminals if the cables were to be pulled 6 Refit the electrical cover t...

Page 26: ...26 INSTALLATION DIAGRAMS INSTALLATION KITCHEN AND BATHROOM CONTROLLERS INSTALLATION KITCHEN CONTROLLER ONLY INSTALLATION BATHROOM CONTROLLERS ONLY MAX...

Page 27: ...ntal effects on the water heater and its operation and or life expectancy If you are unsure of your water quality you can obtain information from your local water supply authority This water heater is...

Page 28: ...er than a single family domestic dwelling All models Year 1 New water heater at Southcorp s sole discretion or component free of charge including labour Water heater installed in a single family domes...