INSTALLATION – WATER HEATER
22
DIMENSIONS AND TECHNICAL DATA
MOUNTING HOLES
2x TOP
2x BOTTOM
Ø127
351
10 to 40
650
707
672
17
49
21
132
127
5
HOT WATER OUTLET
POWER LEAD CONNECTION
GAS
CONNECTION
COLD WATER INLET
POWER LEAD
CONNECTION
HOT WATER
OUTLET
GAS
CONNECTION
COLD WATER
INLET
ELECTRONIC CONTINUOUS FLOW
GAS WATER HEATERS
INTERNAL 627 MODELS - 862, 864, 866 SERIES
SK7166-1 REV_DD 11/12
763
240
131
Ø127
331
130
38
53
119
240
28
107
86
Model
862 627
Rated delivery
(@ 40°C rise)
litres / min
16.7
Recovery
(@ 25°C rise)
litres / min
27
Mass
Empty (unpackaged)
kg
24
Gas Details
Hourly Gas
Consumption
(MJ)
Min Gas Pressure
(kPa)
Test Point Gas Pressure (kPa)
Max Gas Pressure
(kPa)
minimum
maximum
Model
627
627
627
627
627
Natural
205
1.13
0.165
0.900
3.50
Propane
205
2.75
0.252
1.550
3.50
Model numbers: N = Natural, P = Propane.
Letter N or P is included in the model number, e.g. 862627NF, to denote gas type.
F = Frost protection.
Technical data is subject to change.