4-5
TROUBLESHOOTING
TANKLESS WATER HEATER 199
8.
Clean the following components with water:
●
the inside of condensate trap base
●
plastic ball
●
circlip
●
condensate trap cup
●
opening of the flue pipe
9.
Return the plastic ball to the condensate trap base and attach the circlip.
10.
Check that the ball and circlip have been installed correctly (6). Make sure
that the top of the circlip is about 2 1/4” (60 mm) below the edge of the
condensate trap base.
11.
Replace the O-ring (part #150-367) at the bottom of the flue pipe.
12.
Attach the condensate trap base to the bottom by pushing it high enough so
that the securing clips click over the lip (8).
2 ¼"
(60 mm)
–CLICK
!–
13.
Make sure the condensate trap cup is ¾ filled
with water (7) before installation, slide it into the
condensate trap base and rotate it to the right
(clockwise) until it is correctly secured (9).
DANGER
Make sure that the
condensate trap base is
returned to its original
position, firmly locked into
the bottom with no gaps.
Incorrectly attaching the
condensate trap base (or not
attaching it at all) will result
in products of combustion
leaking into the room creating
a dangerous situation.
5
6
7
8
9
10
14.
Slide the flexible hose onto the condensate trap base and into the drain (10)