INSTALLATION
9
DIMENSIONS AND TECHNICAL DATA
HEAT PUMP DIMENSIONS - REMOTE
325 LITRE STORAGE TANK
HEAT PUMP DIMENSIONS - REMOTE
325 LITRE STORAGE TANK
elevation
plan view
Heat pump module models
180536 (R)
180540 (E)
Maximum rated power input
watts
3600
Rated heat pump power input
watts
800
Booster element ratings
kW
2.4, 3.6
Refrigerant type
R134a
Refrigerant circuit pressure
kPa
3000
Mass heat pump module
kg
46
Storage tank capacity
litres
270
325
410
Boost capacity*
litres
180
180
200
Mass tank empty
kg
71
88
112
Mass tank full
kg
341
413
522
* The boost capacity of a low watts density or other than a 2.4 kW or 3.6 kW heating unit,
if used, is 100 litres (270 and 325 litre storage tanks) or 125 litres (410 litre storage tank).