Installing the water heater.

Thermal Expansion

Water Supply Connections

Determine if a check valve exists in the inlet
water line.

It may have been installed in the

cold water line as a separate back flow
preventer, or it may be part of a pressure
reducing valve, water meter or water softener.
A check valve located in the cold water inlet
line can cause what is referred to as a 

“closed

water system.”

A cold water inlet line with no

check valve or back flow prevention device is
referred to as an “open” water system.

As water is heated, it expands in volume and
creates an increase in pressure within the water
system. This action is referred to as 

“thermal

expansion.”

In an “open” water system,

expanding water which exceeds the capacity of
the water heater flows back into the city main
where the pressure is easily dissipated. 

A

“closed water system,”

however, prevents the

expanding water from flowing back into the
main supply line, and the result of 

“thermal

expansion”

can create a rapid and dangerous

pressure increase in the water heater and the
system piping. This rapid pressure increase can
quickly reach the safety setting of the relief

valve, causing it to operate during each heating
cycle. Thermal expansion, and the resulting
rapid and repeated expansion and contraction of
components in the water heater and piping
system can cause premature failure of the relief
valve, and possibly the heater itself. Replacing
the relief valve will not correct the problem. 

The suggested method of controlling thermal
expansion is to install an expansion tank in the
cold water line between the water heater and
the check valve. The expansion tank is
designed with an air cushion built in that
compresses as the system pressure increases,
thereby relieving the over pressure condition
and eliminating the repeated operation of the
relief valve. Other methods of controlling
thermal expansion are also available. Contact
your installing contractor, water supplier, or
plumbing inspector for additional information
regarding this subject.

NOTICE: Do not apply 
heat to the HOT or COLD
water connections. If sweat
connections are used, sweat tubing
to adapter before fitting adapter to
the water connections on heater.
Any heat applied to the water
supply fittings will permanently
damage the dip tube and/or heat
traps.

6

Refer to the illustrations on the following
page for suggested typical installation. The
installation of unions or flexible copper
connectors is recommended on the hot and
cold water connections so that the water
heater may be easily disconnected for
servicing.  Connect cold water supply line to
3/4” pipe connection near bottom of water
heater on the 6 gallon and 20 gallon models.
Install a shut-off valve and a drain valve
(not supplied with heater, except 2 1/2 gal.

models) in cold water line near water heater.
Connect hot water line to 3/4” pipe
connection marked HOT on side near top of
water heater.  On the 2 1/2 gallon models,
the hot and cold water connections are 1/2”
pipe connections and are located on top of
the heater.  Local codes may require an anti-
siphon device on the water inlet of a side
connect water heater.

Summary of Contents for 120 Volt

Page 1: ...cancer birth defects or other reproductive harm 2 through 30 Gallon Capacity 120 and 240 Volt Models LISTED 786H AP10227 10 11 03 Printed in USA Use Care Manual With Installation Instructions for the...

Page 2: ...ou can find them on a label on the appliance Staple sales slip or cancelled check here Proof of the original purchase date is needed to obtain service under the warranty Your safety and the safety of...

Page 3: ...uctions in how to adjust the thermostat s DANGER Hotter water increases the potential for Hot Water SCALDS D A N G E R HOT Water temperature over 125 F can cause severe burns instantly or death from s...

Page 4: ...with generic earthquake bracing instructions can be obtained from Office of the State Architect 400 P Street Sacramento CA 95814 or you may call 916 324 5315 or ask a water heater dealer However appl...

Page 5: ...such a manner that the thermostat and element access panels can be removed to permit inspection and servicing such as removal of elements or checking controls The water heater and water lines should...

Page 6: ...he suggested method of controlling thermal expansion is to install an expansion tank in the cold water line between the water heater and the check valve The expansion tank is designed with an air cush...

Page 7: ...s or persons and to eliminate potential water damage Piping used should be of a type approved for hot water distribution The discharge line must be no smaller than the outlet of the valve and must pit...

Page 8: ...l for wiring connections The branch circuit wiring should include either Metallic conduit or metallic sheathed cable approved for use as a grounding conductor and installed with fittings approved for...

Page 9: ...vices other than those authorized by the manufacturer into onto or in conjunction with the water heater The use of unauthorized energy saving devices may shorten the life of the water heater and may e...

Page 10: ...ection arrangement Typical side connection arrangement Relief Valve Insulation Installation CAUTION Ensure the T P Valve opening is not obstructed by the insulation Heat Trap For increased energy effi...

Page 11: ...nt room to service heater Water heater completely filled with water Air purged from water heater and piping Water connections tight and free of leaks Temperature and Pressure Relief Valve properly ins...

Page 12: ...Do not smoke or use an open flame near the faucet at the time it is open CAUTION The cause of the high temperature condition must be investigated by qualified service technician and corrective action...

Page 13: ...ure Setting The temperature of the water in the water heater can be regulated by setting the temperature dial of the adjustable surface mounted thermostat s located behind the jacket access panel s Du...

Page 14: ...nd or replacement as operation with the anode rod removed will shorten the life of the glass lined tank and will exclude warranty coverage Care and cleaning of the water heater Draining the Water Heat...

Page 15: ...y may be off Make sure electric supply to water heater and disconnect switch if used are in the ON position The thermostat may See the Temperature regulation of the water heater be set set too low sec...

Page 16: ...below and number of parts desired CAUTION For your safety DO NOT attempt repair of electrical wiring thermostat s heating elements or other operating controls Refer repairs to qualified service person...

Page 17: ...ed below and number of parts desired CAUTION For your safety DO NOT attempt repair of electrical wiring thermostat s heating elements or other operating controls Refer repairs to qualified service per...

Page 18: ...ER BEFO RE SERV ICING R E SE T R E S E T 140 130 120 110 100 90 T H E R M O D I S C TURN OFF POW ER BEFO RE SERV ICING 140 130 120 110 100 90 T H E R M O D I S C R E SE T R E S E T 140 130 120 110 10...

Page 19: ...he Manufacturer s National Service Department at the following address 2600 Gunter Park Drive Montgomery Alabama 36109 1413 Phone 1 800 432 8373 When contacting the manufacturer the following informat...

Page 20: ...T TO ELECTRICAL DISTRIBUTION PANEL JUNCTION BOX N 120 V Plug Connected Cord Set ONLY SINGLE ELEMENT FIG B BRANCH CIRCUIT TO ELECTRICAL DISTRIBUTION PANEL UPPER THERMOSTAT HIGH TEMP LIMIT ECO 2 UPPER H...

Reviews: