background image

10

Installing the water heater.

For increased energy efficiency, some
water heaters have been supplied with
a 2-3/8” section of pipe insulation.

Please install the insulation, according to
the illustrations above, that best meets
your requirements.

Slip the insulation cover over the T&P
Valve through the center hole and align
the hole in the side with the opening of
the T&P Valve.

R

E

L

I

E

F

V

A

L

V

E

COLD

HOT

Typical top connection arrangement

Typical side connection arrangement

Relief Valve Insulation Installation

CAUTION: Ensure the

T&P Valve opening is not
obstructed by the insulation.

Heat Trap

For increased energy efficiency, some
water heaters have been supplied with
factory installed internal or external heat
traps  in the hot outlet and cold water inlet
openings.

NOTICE: Do not apply heat to the HOT or
COLD water connections. If sweat
connections are used, sweat tubing to
adapter before fitting adapter to the water
connections on heater. Any heat applied to
the water supply fittings will permanently
damage the dip tube and/or heat traps.

Summary of Contents for 120 Volt

Page 1: ...cancer birth defects or other reproductive harm 2 through 30 Gallon Capacity 120 and 240 Volt Models LISTED 786H AP10227 10 11 03 Printed in USA Use Care Manual With Installation Instructions for the...

Page 2: ...ou can find them on a label on the appliance Staple sales slip or cancelled check here Proof of the original purchase date is needed to obtain service under the warranty Your safety and the safety of...

Page 3: ...uctions in how to adjust the thermostat s DANGER Hotter water increases the potential for Hot Water SCALDS D A N G E R HOT Water temperature over 125 F can cause severe burns instantly or death from s...

Page 4: ...with generic earthquake bracing instructions can be obtained from Office of the State Architect 400 P Street Sacramento CA 95814 or you may call 916 324 5315 or ask a water heater dealer However appl...

Page 5: ...such a manner that the thermostat and element access panels can be removed to permit inspection and servicing such as removal of elements or checking controls The water heater and water lines should...

Page 6: ...he suggested method of controlling thermal expansion is to install an expansion tank in the cold water line between the water heater and the check valve The expansion tank is designed with an air cush...

Page 7: ...s or persons and to eliminate potential water damage Piping used should be of a type approved for hot water distribution The discharge line must be no smaller than the outlet of the valve and must pit...

Page 8: ...l for wiring connections The branch circuit wiring should include either Metallic conduit or metallic sheathed cable approved for use as a grounding conductor and installed with fittings approved for...

Page 9: ...vices other than those authorized by the manufacturer into onto or in conjunction with the water heater The use of unauthorized energy saving devices may shorten the life of the water heater and may e...

Page 10: ...ection arrangement Typical side connection arrangement Relief Valve Insulation Installation CAUTION Ensure the T P Valve opening is not obstructed by the insulation Heat Trap For increased energy effi...

Page 11: ...nt room to service heater Water heater completely filled with water Air purged from water heater and piping Water connections tight and free of leaks Temperature and Pressure Relief Valve properly ins...

Page 12: ...Do not smoke or use an open flame near the faucet at the time it is open CAUTION The cause of the high temperature condition must be investigated by qualified service technician and corrective action...

Page 13: ...ure Setting The temperature of the water in the water heater can be regulated by setting the temperature dial of the adjustable surface mounted thermostat s located behind the jacket access panel s Du...

Page 14: ...nd or replacement as operation with the anode rod removed will shorten the life of the glass lined tank and will exclude warranty coverage Care and cleaning of the water heater Draining the Water Heat...

Page 15: ...y may be off Make sure electric supply to water heater and disconnect switch if used are in the ON position The thermostat may See the Temperature regulation of the water heater be set set too low sec...

Page 16: ...below and number of parts desired CAUTION For your safety DO NOT attempt repair of electrical wiring thermostat s heating elements or other operating controls Refer repairs to qualified service person...

Page 17: ...ed below and number of parts desired CAUTION For your safety DO NOT attempt repair of electrical wiring thermostat s heating elements or other operating controls Refer repairs to qualified service per...

Page 18: ...ER BEFO RE SERV ICING R E SE T R E S E T 140 130 120 110 100 90 T H E R M O D I S C TURN OFF POW ER BEFO RE SERV ICING 140 130 120 110 100 90 T H E R M O D I S C R E SE T R E S E T 140 130 120 110 10...

Page 19: ...he Manufacturer s National Service Department at the following address 2600 Gunter Park Drive Montgomery Alabama 36109 1413 Phone 1 800 432 8373 When contacting the manufacturer the following informat...

Page 20: ...T TO ELECTRICAL DISTRIBUTION PANEL JUNCTION BOX N 120 V Plug Connected Cord Set ONLY SINGLE ELEMENT FIG B BRANCH CIRCUIT TO ELECTRICAL DISTRIBUTION PANEL UPPER THERMOSTAT HIGH TEMP LIMIT ECO 2 UPPER H...

Reviews: