DIMENSION SPECIFICATION 

Classic models 

 

 

Classic Models 

Dimension 

3 Litre 

5 Litre 

7.5 Litre 

10 Litre 

15 Litre 

25 Litre 

40 Litre 

J mm 

46 

 

 

 

 

 

 

46

46

46

75

75

75

K mm 

189 

 

 

 

 

 

 

241

241

241

340

340

340

L mm 

31 

 

 

 

 

 

 

31

31

31

20

20

20

MOUNTING DIMENSION SPECIFICATION 

All models 

 

Figure 2: Overflow / Vent Connection

 

Figure 4: Dimension Specification

Dimension 

3 Litre 

5 Litre 

7.5 Litre 10 Litre

15 Litre

25 Litre 

40 Litre 

mm 

 

 

 

 

 

 

 

283

334

334

334

490

490

490

mm 

 

 

 

 

 

 

 

143

176

176

176

180

235

325

mm 

 

 

 

 

 

 

 

400

430

515

615

615

615

615

mm 

 

 

 

 

 

 

 

234

267

267

267

271

326

416

mm 

 

 

 

   

 

 

15

15

15

15

8

8

8

mm 

 

 

 

 

 

 

 

50

50

50

50

32

32

32

mm 

 

 

 

 

 

 

 

53

53

53

53

103

103

103

mm 

 

 

 

 

 

 

 

18

18

18

18

32

32

32

mm 

 

 

 

 

 

 

 

212

245

245

245

249

304

394

mm 

 

 

 

 

 

 

 

142

167

167

167

245

245

245

 

Figure 3: Mounting Dimension Specifications 

6. 

7. 

 

 

Summary of Contents for 10 Litre

Page 1: ...Part No 316937A OWNERS GUIDE INSTALLATION INSTRUCTIONS CLASSIC SERIES POWDER COATED Models 3 5 7 5 10 15 25 40 Litre STAINLESS STEEL Models 7 5 10 15 25 40 Litre IMPORTANT PLEASE LEAVE WITH THE OWNER...

Page 2: ...ction 4 H Tap Outlet 5 J Electrical Requirements 5 4 OPERATION 5 MOUNTING DIMENSION SPECIFICATION FOR ALL MODELS drawing 6 DIMENSION SPECIFICATION FOR ALL MODELS drawing 7 5 FOR UNITS WITH A TIMER 8 A...

Page 3: ...ct your local Rheem office for advice Be sure that the mounting screws are securely inserted into the keyhole slots The screws MUST be anchored in such a way that they will hold the weight of the unit...

Page 4: ...n pipe must discharge to waste at a point where no scald injury nuisance nor inconvenience is caused to people in the immediate vicinity WARNINGS Ensure the overflow vent line remains open because the...

Page 5: ...mise the boiling wate delivery 220 240 Volts AC 50 Hz Single Phase 10 Amps on 3 5 7 5 10 15 litre models 15 Amps on 25 litre model 20 Amps on 40 litre model A flexible cord complete with a plug is sup...

Page 6: ...tre 10 Litre 15 Litre 25 Litre 40 Litre J mm 46 46 46 46 75 75 75 K mm 189 241 241 241 340 340 340 L mm 31 31 31 31 20 20 20 MOUNTING DIMENSION SPECIFICATION All models Figure 2 Overflow Vent Connecti...

Page 7: ...e 25 Litre 40 Litre A mm 283 334 334 334 490 490 490 B mm 143 176 176 176 180 235 325 C mm 400 430 515 615 615 615 615 D mm 234 267 267 267 271 326 416 E mm 15 15 15 15 8 8 8 F mm 50 50 50 50 32 32 32...

Page 8: ...hows STD Pressing the UP button alternates the STD AUTO icons STD operation means that the unit operates 24 hours a day Auto mode reverts the unit to operate at the pre set times on the timer Press th...

Page 9: ...XXX C Press the Cancel button to revert back to the main menu Display Shows Remaining Life XXXX litres iv For Calibration Reset mode Press the Cancel or Accept button to revert back to the main menu...

Page 10: ...ement is properly wired then check its resistance Replace if broken Electronic Controller failure Test the electronic controller 2 The unit fills water to low level and does not heat Thermistor failur...

Page 11: ...NOTES 11...

Page 12: ...re does not cover any plumbing or electrical parts supplied by the installer and not an integral part of the Boiling Water Unit e g pressure limiting valve stop cock electrical switches pumps or fuses...

Reviews: