WARRANTY

In addition to your legal rights, Rheem makes the following promise to the owner. We will repair or, if 

necessary, replace a defective boiling water unit or part of it, which has failed due to faulty manufacture on the 
following terms and conditions: 
WARRANTY PERIOD 

AGE OF BOILING WATER UNIT 

FROM THE DATE OF INSTALLATION 

WARRANTY COVERS ALL BOILING WATER UNITS DOMESTIC, 

COMMERCIAL OR INDUSTRIAL 

Up to (1) year  

Free replacement of failed component, or if necessary, replacement of 
the Boiling Water Unit, free of charge, including labour.** 

** Refer to item 3, Warranty Conditions. 

Should your boiling water unit need service under warranty, please call RHEEM SERVICE on 

131 031 or refer to the yellow pages under Water Heaters for your nearest local service agent. 

WARRANTY CONDITIONS: 

1.The Boiling Water Unit must be installed in accordance with the installation instructions, supplied with the 

Boiling Water Unit, and in accordance with all relevant statutory and local requirements of the state in which 
the Boiling Water Unit is installed. 

2.Where a failed component or Boiling Water Unit is replaced under Warranty, the balance of the original Warranty 

Period will remain effective. The replaced part or Boiling Water Unit does not carry a new Warranty. 

3.Where the Boiling Water Unit is installed outside the boundaries of a metropolitan area as defined by 

Rheem, or beyond 25 km from a regional Rheem branch office, or a Rheem Authorised Service Centre, the 
cost of transport, insurance and travelling costs between the nearest Rheem Authorised Service Centre’s 
premises and the installed site will be for the account of the owner. 

4.The Warranty only applies to the Boiling Water Unit and therefore does not cover any plumbing or electrical 

parts supplied by the installer and not an integral part of the Boiling Water Unit, e.g. pressure limiting valve, 
stop cock, electrical switches, pumps or fuses. 

WARRANTY INFORMATION 

WARRANTY EXCLUSIONS: 
REPAIR AND REPLACEMENT WORK WILL BE CARRIED OUT AS PER THE RHEEM WARRANTY (ABOVE), 
HOWEVER THE FOLLOWING EXCLUSIONS MAY CAUSE THE BOILING WATER UNIT WARRANTY TO 
BECOME VOID, AND MAY INCUR A CHARGE FOR SERVICE AND COST OF REPLACED PARTS. 
1.

 

Accidental damage; Acts of God; failure due to misuse; incorrect installation, attempts to repair the unit other 

than by a Rheem Authorised Service Agent, or the Rheem Service Department. 

2.

 

Where it is found that there is nothing wrong with the boiling water unit; where the complaint is related to low 

or high water pressure; where there is no flow of hot water due to faulty plumbing or a blocked filter; where 

water leaks are related to plumbing work and not the boiling water unit or its components, where there is a 

failure of electricity or water supplies. 

3.

 

Where the boiling water unit or its component has failed directly or indirectly as a result of high water 

pressure. 

4.

 

Where the boiling water unit is located in a position that does not comply with the Rheem installation 

instructions or relevant statutory requirements causing the need for major dismantling or removal of 

cupboards. 

5.

 

Subject to any statutory provisions to the contrary claims for damage to furniture, carpets, walls, foundations, 

or any other consequential loss either directly or indirectly due to leakage from a boiling water unit. 

6.

 

 Repairs to the boiling water unit due to scale formation in the waterways when the heater has been 

connected to a harmful water supply as outlined in the owners guide. 

Contact details:                  

RHEEM AUSTRALIA PTY LTD                                                                    FOR SERVICE TELEPHONE 
A B.N. 21 098 823 511                                                                                                  131 031 

.

www.rheem.com.au                                                                                           or refer local Yellow Pages               

 

 

12. 

 

Part No. 316937A 

 

 

OWNERS GUIDE  

INSTALLATION INSTRUCTIONS 

 

 CLASSIC 

SERIES 

POWDER COATED 

Models 3, 5, 7.5, 10, 15, 25, & 40 Litre 

STAINLESS STEEL 

Models 7.5, 10, 15, 25, & 40 Litre 

 

 

 

 

 

 

 
 

IMPORTANT, PLEASE LEAVE WITH THE OWNER 

Summary of Contents for 10 Litre

Page 1: ...Part No 316937A OWNERS GUIDE INSTALLATION INSTRUCTIONS CLASSIC SERIES POWDER COATED Models 3 5 7 5 10 15 25 40 Litre STAINLESS STEEL Models 7 5 10 15 25 40 Litre IMPORTANT PLEASE LEAVE WITH THE OWNER...

Page 2: ...ction 4 H Tap Outlet 5 J Electrical Requirements 5 4 OPERATION 5 MOUNTING DIMENSION SPECIFICATION FOR ALL MODELS drawing 6 DIMENSION SPECIFICATION FOR ALL MODELS drawing 7 5 FOR UNITS WITH A TIMER 8 A...

Page 3: ...ct your local Rheem office for advice Be sure that the mounting screws are securely inserted into the keyhole slots The screws MUST be anchored in such a way that they will hold the weight of the unit...

Page 4: ...n pipe must discharge to waste at a point where no scald injury nuisance nor inconvenience is caused to people in the immediate vicinity WARNINGS Ensure the overflow vent line remains open because the...

Page 5: ...mise the boiling wate delivery 220 240 Volts AC 50 Hz Single Phase 10 Amps on 3 5 7 5 10 15 litre models 15 Amps on 25 litre model 20 Amps on 40 litre model A flexible cord complete with a plug is sup...

Page 6: ...tre 10 Litre 15 Litre 25 Litre 40 Litre J mm 46 46 46 46 75 75 75 K mm 189 241 241 241 340 340 340 L mm 31 31 31 31 20 20 20 MOUNTING DIMENSION SPECIFICATION All models Figure 2 Overflow Vent Connecti...

Page 7: ...e 25 Litre 40 Litre A mm 283 334 334 334 490 490 490 B mm 143 176 176 176 180 235 325 C mm 400 430 515 615 615 615 615 D mm 234 267 267 267 271 326 416 E mm 15 15 15 15 8 8 8 F mm 50 50 50 50 32 32 32...

Page 8: ...hows STD Pressing the UP button alternates the STD AUTO icons STD operation means that the unit operates 24 hours a day Auto mode reverts the unit to operate at the pre set times on the timer Press th...

Page 9: ...XXX C Press the Cancel button to revert back to the main menu Display Shows Remaining Life XXXX litres iv For Calibration Reset mode Press the Cancel or Accept button to revert back to the main menu...

Page 10: ...ement is properly wired then check its resistance Replace if broken Electronic Controller failure Test the electronic controller 2 The unit fills water to low level and does not heat Thermistor failur...

Page 11: ...NOTES 11...

Page 12: ...re does not cover any plumbing or electrical parts supplied by the installer and not an integral part of the Boiling Water Unit e g pressure limiting valve stop cock electrical switches pumps or fuses...

Reviews: