background image

LIMITED PRODUCT WARRANTY 

 
 

Reimann & Georger Corporation 

Hoisting and Construction Products 

 
 

A.

 

LIMITED WARRANTY 

 

Reimann & Georger Corporation (the “Manufacturer”) warrants to the original purchaser (the “Buyer”) that all Reimann & 
Georger Hoisting and Construction products shall be free of defects in material and workmanship for a period of one (1) 
year from date of original purchase. 

 

B.

 

MANUFACTURER’S OBLIGATIONS 

 

The Manufacturer’s sole obligation under this Limited Warranty is the repair or, at the Manufacturer’s discretion, the 
replacement of parts found to be defective.  Parts and equipment must have authorization from the Manufacturer prior to 
return to the Manufacturer or repair by an authorized service person.  Costs of transportation and other expenses 
connected with replacing or repairing parts are not covered under this Limited Warranty. 

 

C.

 

PARTS MANUFACTURED BY OTHERS 

 

This Limited Warranty does not cover any parts manufactured by others.  Such parts are subject to the warranty, if any, of 
their respective manufacturers, and are to be repaired only by a respective authorized service person for such parts.  The 
Manufacturer shall have no obligation to undertake repairs of parts manufactured by others. 

 

D.

 

NO SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES 

 

IN NO EVENT SHALL THE MANUFACTURER BE LIABLE TO THE BUYER OR ANY OTHER PERSON 
FOR ANY INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL LOSSES OR DAMAGES 
CONNECTED WITH THE USE OF THE PRODUCT UNDER THIS LIMITED WARRANTY.  SUCH 
DAMAGES FOR WHICH THE MANUFACTURER SHALL NOT BE RESPONSIBLE INCLUDE, BUT ARE 
NOT LIMITED TO, LOST TIME AND CONVENIENCE, LOSS OF USE OF THE PRODUCT, THE COST OF A 
PRODUCT RENTAL, COSTS OF GASOLINE, TELEPHONE, TRAVEL, OR LODGING, THE LOSS OF 
PERSONAL OR COMMERCIAL PROPERTY, AND THE LOSS OF REVENUE. 

 

E.

 

NO LIABILITY IN EXCESS OF PURCHASE PRICE 

 

IN NO EVENT SHALL THE MANUFACTURER’S OBLIGATIONS UNDER THIS LIMITED WARRANTY 
EXCEED THE PURCHASE PRICE OF THE PRODUCT. 

 

F.

 

NO EXTENSION OF STATUTE OF LIMITATIONS 

 

ANY REPAIRS PERFORMED UNDER THIS WARRANTY SHALL NOT IN ANY WAY EXTEND THE 
STATUTES OF LIMITATIONS FOR CLAIMS UNDER THIS LIMITED WARRANTY. 

 

G.

 

WAIVER OF OTHER WARRANTIES 

 

THE EXPRESS WARRANTIES SET FORTH IN THIS LIMITED WARRANTY ARE IN LIEU OF AND 
EXCLUDE ANY AND ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT 
LIMITED TO, THE IMPLIED WARRANTIES OR MERCHANTABILITY AND FITNESS FOR A 
PARTICULAR PURPOSE. 

 

H.

 

PROCEDURE FOR WARRANTY PERFORMANCE 

 

If the product fails to perform to the Manufacturer’s specifications, the Buyer must provide the Manufacturer with the 
applicable model and serial numbers, the date of purchase, and the nature of the problem. 

9912 

 

Summary of Contents for HYDRAPAK HV185510C

Page 1: ...HV185510C HYDRAPAK INSTRUCTIONS REIMANN GEORGER CORPORATION CONSTRUCTION PRODUCTS BUFFALO NY P N 6122037 11 25 13...

Page 2: ...e 5 3 1 2 Checking the Hydraulic System 5 3 2 Starting and Operating the HydraPak 6 3 3 Stopping the HydraPak 7 4 INSPECTION AND MAINTENANCE 8 4 1 General Maintenance Rules 8 4 2 Hydraulic System Insp...

Page 3: ...ate this HydraPak or the associated hydraulic tools It is recommended that this checklist be maintained as a permanent record Insure construction area is secured from all unauthorized personnel All cr...

Page 4: ...only accidents 1 3 HYDRAPAK SAFETY LABELS These labels warn you of potential hazards that could cause injury Read them carefully If a label comes off or becomes illegible contact Reimann Georger Corp...

Page 5: ...oses or fittings while the HydraPak is running 18 At end of operation secure the HydraPak and the associated hydraulic equipment to prevent unauthorized use Never assume you will find the equipment in...

Page 6: ...sh Filler Breather 100 mesh Electrical Charging System 12 14V 16 AMP regulated to battery Battery Type 12V 15 Plate 400 CCA Fuse Automotive Ignition 5 AMP Blade Type Fan 25 AMP Standard Features Hour...

Page 7: ...ering spare parts or requesting assistance in service The HydraPak has a product nameplate that shows the model and serial numbers as shown in Figure 2 1 Record the model and serial numbers for future...

Page 8: ...Corporation for replacement information 4 Construction area is to be kept clear of unauthorized personnel Place barricades or secure the area in such a manner that no personnel can be injured 5 Posit...

Page 9: ...aPak with the same number 1 or 2 group identification as the return tank line that was used d When making connections do not over stretch the hoses or bend them at a sharp angle WARNING ENSURE HYDRAUL...

Page 10: ...ent in the same condition that you left it Proceed as follows 1 Let the HydraPak run at idle for about five 5 minutes to cool hydraulic oil and components or for ten 10 minutes under severe operating...

Page 11: ...WIRE FROM THE BATTERY TERMINAL WARNING DO NOT ADJUST OR REMOVE HYDRAULIC COMPONENTS LINES OR FITTINGS WHILE THE HYDRAPAK IS RUNNING OR WHENEVER THE HYDRAULIC FLUID IS HOT WARNING LIQUID UNDER HIGH PRE...

Page 12: ...D MAINTENANCE 1 The following rules must be observed when doing engine maintenance a Do not check for a spark with the spark plug removed Use an approved tester b Do not crank the engine with the spar...

Page 13: ...eplace engine oil filter 100 hrs Check clean and replace spark plug 100 hrs Have cylinder head removed and cleaned leaded fuel 100 hrs Have cylinder head removed and cleaned unleaded fuel 200 hrs Repl...

Page 14: ...raulic tool being used check hydraulic tool requirement c Air in fluid inspect for oil leaks and repair to correct d No work being done open center tools only produce pressure under load No hydraulic...

Page 15: ...sure requirement Extension hoses too long a Hoses over 50 feet long add sufficient friction to the hydraulic system to slow down the hydraulic tool slightly b Where possible use as few quick disconnec...

Page 16: ...rn out causing air to be drawn into pump Air leak in suction line Improper type of hydraulic oil as an original equipment manufacturer RGC uses a Grade ISO VG 32 hydraulic oil If you have any question...

Page 17: ...move throttle lever replace actuator as described in the engine manual Auto idle override switch has been left in bypass push switch down to put engine in auto idle mode Engine races uncontrollably a...

Page 18: ...CORE 10 TUBE 11 5411513 1 FAN 12 12 5800387 2 COTTER HAIR PIN 13 6918113 1 HYDRAULIC PUMP DBL 5 5 10 P 14 5400861 1 BATTERY 14 5401564 1 BATTERY STRAP 15 6910454 1 PUMP BRACKET 15 6901502 1 PUMP BRAC...

Page 19: ...Figure 6 1 HV185510 Assembly Drawing 16...

Page 20: ...IAL INCIDENTAL OR CONSEQUENTIAL DAMAGES IN NO EVENT SHALL THE MANUFACTURER BE LIABLE TO THE BUYER OR ANY OTHER PERSON FOR ANY INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL LOSSES OR DAMAGES CONNECTED W...

Page 21: ...y normal wear and tear by improper adjustment or alteration by alterations not completed by authorized service personnel or by failure of product parts from such alterations 4 Costs of repairing damag...

Reviews: