background image

PTZ

User Manual

33

3.6.3 Network Configuration

1) Network port

Data port:

set the data port,the device will restart automatically after changed(default 3000,0-65535 optional).

Web Port:

Set Web port,the device will restart automatically after changed (default is 80,0-65535 is optional).

Onvif Port:

Set Onvif port,the device will restart automatically after changed(default 2000,0-65535 optional).

Soap Port:

Set Soap port (default 1936,0-65535 optional).

RTMP Port:

Set RTMP port (default 1935,0-65535 optional).

RTSP Port:

Set RTSP port,the device will restart automatically after changed (default 554,0-65535 optional).

Visca Port:

Set Visca port,the device will restart automatically after changed (default 3001,0-65535 optional).

Click on the "Save" button,it will be valid when display "Save successful".

RTMP access: RTMP: / / equipment IP address: 1935 / live/av0 (av0 main stream; av1 second stream)

RTMP Access : rtmp:// equipment IP address: 1935 / live/av0 (av0 main stream; av1 second stream)

2) Ethernet parameters

DHCP:

Enable or disable obtain IP automatically can be set. Save changes and reboot the device to takes effect

( Default:OFF)

IP Address:

Set the IP address,save changes and reboot the device to takes effect (default 192.168.5.163)

Note: This IP address is the same with the one used to login Web page.

Subnet Mask:

Set the subnet mask (default 255.255.255.0).

Default Gateway:

Set the default gateway (default 0.0.0.0).

Physical Address:

Set the physical address (the parameter is read-only but can not be modified).

Click on the "Save" button,it will be valid when display "Save successful". (Note: To prevent IP conflicts When

modify ).

3) DNS Parameters

Preferred DNS server:

set the preferred DNS server. (Default 0.0.0.0).

Alternate DNS server:

Alternate DNS server settings. (Default 0.0.0.0).

Click on the "Save" button,it will be valid when display "Save successful".

4) GB28181

Switch:

set whether open GB28181,can check

Time Synchronization:

whether synchronization time is set,you can check

Stream Type:

stream type setting (the default main stream,secondary stream optional)

Sign effective time (in seconds):

3600 Range 5-65535

Heartbeat time (seconds):

60 Range 1-65535

Register ID:

34020000001320000001

Register User name:

IPC

Register Password:

12345678

Equipment ownership:

Users can add their own

Administrative regions:

Users can add their own

Alarm Zone:

Users can add their own

Equipment installation address:

Users can add their own

Local SIP Port:

5060 Range 0-65535

GB28181 Server Address:

IP address of the computer

Server SIP Port:

5060 Range 0-65535

Server ID:

34020000002000000001

Click on the "Save" button,it will be valid when display "Save successful".

3.6.4 System Configuration

Summary of Contents for RGB12X-PTZ-WH

Page 1: ...PTZ Camera User Manual Article No RGB RD UM PTZ E001 Version V1 0...

Page 2: ...232 Interface 11 2 2 Bracket mount 13 Chapter 3 Use Your Product 16 3 1 Video Output 16 3 1 1 Power on initial configuration 16 3 1 2 Video Output 16 3 2 Remote Controller 17 3 2 1 Keys Instruction 1...

Page 3: ...t us 37 5 2 Camera Maintenance and Troubleshooting 38 5 2 1 Camera Maintenance 38 5 2 2 Troubleshooting 38 Chapter 5 Appendix 40 6 1 VISCA Protocol List 40 6 1 1 Camera Return Command 40 6 1 2 Camera...

Page 4: ...ms and software on the date of commissioning at latest 30 days after the transfer of risks In the event of justified notice of compliant RGBlink can repair the fault or provide a replacement at its ow...

Page 5: ...output terminals A protective ground connection by way of the grounding conductor in the power cord is essential for safe operation Use the Proper Power Cord Use only the power cord and connector spec...

Page 6: ...ilation and space for all components Electric Safety Installation and operation must accord with electric safety standard Polarity of power supply The power supply of the product is 12V the max electr...

Page 7: ...the Box Power Adapter 1 RS232 serial port line 1 Remote control 1 1 2 Product Overview 1 2 1 Product Model The User Manual is applicable to 12X PTZ Camera RGB12X PTZ WH 20X PTZ Camera RGB20X PTZ WH 1...

Page 8: ...it works extremely quiet and moves smoothly and very quickly to designated position 6 Multi Format Video Outputs support HDMI 3G SDI The 3G SDI is available for 100m transmission at 1080p60 format 7...

Page 9: ...ltaneously Video Compression forma H 265 H 264 Control Signal Interface RS 232 Ring through RS232 output RS 485 Control Protocol Protocol VISCA Pelco D Pelco P Audio Input Interface Double track 3 5mm...

Page 10: ...232 Control Interface output 12 10 100M Network Interface 3 Remote Controller Receiver Light 8 RS485 Input left right 13 DC12V Input Power Supply Socket 4 Bottom Dial Switch 9 Audio Input Interface 5...

Page 11: ...FF to select different modes of operation as shown in Table 2 1 Table 2 1 Dial Switch setting 2 1 3 RS 232 Interface 1 RS 232 interface Computer or keyboard and camera connection method Camera Windows...

Page 12: ...nsmit Data 4 GND System Ground 5 RXD Receive Data 6 GND System Ground 7 IR OUT IR Commander Signal IR 8 NC No Connection NO Port Definition 1 DCD Data Carrier Detect 2 RXD Receive Data 3 TXD Transmit...

Page 13: ...PTZ User Manual 13 2 2 Bracket Mount Note Bracket can only be wall mounted or upside down mounted on template and concrete wall but can not be installed on plasterboard 1 Wall mount step...

Page 14: ...PTZ User Manual 14 2 Upside down mount step...

Page 15: ...PTZ User Manual 15 Note The bracket mount is the optional accessory...

Page 16: ...ction Port refer to No 12 in Figure2 1 b Webpage Login Open your browser and enter 192 168 5 163 in the address bar factory default press Enter to enter into the login page click on the player is not...

Page 17: ...o Focus Enter into auto focus mode Manual Focus The camera focus mode is manual Switch the camera focus mode to manual focus by pressing focus or focus to adjust 6 Zoom Control Key Zoom Lens near Zoom...

Page 18: ...key combination is required do it in sequence For example F1 means press first and then press and last press F1 1 Camera Selection Select the camera address to control 2 Pan Tilt Control 1 Clear all...

Page 19: ...IN press ZOOM key ZOOM OUT press ZOOM key Press and hold the key the camera will keep zooming in or zooming out and stops as soon as the key is released 4 Focus Control Focus near Press focus key Vali...

Page 20: ...a preset position the user can press the CLEAR PRESET key first and then press the number key 0 9 to clear the relative preset Note press the key three times continually to cancel all the presets 7 C...

Page 21: ...stem Setting Move the pointer to the Setup in the Main Menu click the HOME key and enter into the System Setting as shown below SETUP Protocol Auto Visca Address 1 Visca Address Fix OFF PELCO PAddress...

Page 22: ...ker 50Hz G Limit 3 DRC 2 Select Change Value Menu Back Mode Auto Manual Shutter priority Iris priority and Brightness priority EV On Off only available in auto mode Compensation Level 7 7 only availab...

Page 23: ...OLOR WB Mode Auto RG Tuning 0 BG Tuning 0 Saturation 100 Hue 7 AWB Sensitivity High Select Change Value Menu Back WB Mode Auto 3000K 3500K 4000K 4500K 5000K 5500K 6000K 6500K 7000K Manual One Push Red...

Page 24: ...ault 0 47 0 50 0 52 0 55 DZoom digital zoom options On Off DCI Dynamic Contrast Off 1 8 4 FOCUS Move the pointer to the FOCUS in the Menu click the HOME and enter the FOCUS as follow FOCUS Focus Mode...

Page 25: ...nter the P T Z as follow P T Z Speed by zoom ON Zoom speed 8 Image Freezing OFF Acc Curve Slow Select Change Value Menu Back Depth of Field Only effective for remote controller On Off When zoom in the...

Page 26: ...parameter to save it after powered off 3 3 6 Version Move the pointer to the VERSION in the Main Menu click the HOME and enter the VERSION as follow MCU Version Display MCU version information Camera...

Page 27: ...ng cable Internet connection mode Connect the camera to Internet by Router or Switch and user can log in the device by browser Note Please do not put the power and network cable in places where can be...

Page 28: ...IP address of the camera Note The IP address to be added cannot be same with that of other computers or devices The existence of this IP address needs to be verified before adding 3 Click the Start an...

Page 29: ...iew playback and cancel no option for configuration Note Web access supported browsers IE 360 browser Google browser and other conventional browser 3 5 2 Preview After successful login into the manage...

Page 30: ...ra to make new setting effect 3 6 2 Video Configuration 1 Video encoding Code stream Different video output mode setting use different streams Main stream secondary stream Compression Format Set the v...

Page 31: ...s Focus mode focus range focus sensitivity can be set Focus Mode set the focus mode the default auto manual optional Focus range set the focus range the default middle the upper and lower optional Foc...

Page 32: ...noise reduction level default Auto 1 7 and Off optional 3D Noise Reduction Set 3D noise reduction level default 5 1 8 and Off optional Dynamic dead pixel correction Set Dynamic dead pixel correction d...

Page 33: ...is IP address is the same with the one used to login Web page Subnet Mask Set the subnet mask default 255 255 255 0 Default Gateway Set the default gateway default 0 0 0 0 Physical Address Set the phy...

Page 34: ...r domain name Set NTP server address or domain name default time nits gov Valid after setting NTP server synchronization NTP Server Port Sets the NTP server port default 123 Valid after setting NTP se...

Page 35: ...sion upgrade is complete you need to restore factory defaults a through web to restore the factory default configuration b through the recovery menu c remote control shortcut 6 Choose one of the above...

Page 36: ...PTZ User Manual 36 Chapter 4 Ordering Codes 4 1 Product 981 0011 01 0 RGB12X PTZ WH 12X PTZ Camera 981 0011 02 0 RGB20X PTZ WH 20X PTZ Camera...

Page 37: ...PTZ User Manual 37 Chapter 5 Support 5 1 Contact us...

Page 38: ...the machine is set back to the factory defaults remote control addresses need to be back to 1 too b Check whether the battery is installed on the remote controller or low c Check the camera working mo...

Page 39: ...PTZ User Manual 39...

Page 40: ...ommand packet Note AddressSet Broadcast 88 30 0p FF p Address setting IF_Clear Broadcast 88 01 00 01 FF I F Clear CommandCancel 8x 21 FF CAM_Power On 8x 01 04 00 02 FF Power ON OFF Off 8x 01 04 00 03...

Page 41: ...F Down 8x 01 04 0A 03 FF Direct 8x 01 04 4A 00 00 0p 0q FF pq Shutter Position CAM_Iris Reset 8x 01 04 0B 00 FF Iris Setting Up 8x 01 04 0B 02 FF Down 8x 01 04 0B 03 FF Direct 8x 01 04 4B 00 00 0p 0q...

Page 42: ...0 13 190 14 200 CAM_IDWrite 8x 01 04 22 0p 0q 0r 0s FF pqrs Camera ID 0000 to FFFF SYS_Menu ON 8x 01 04 06 06 02 FF Turn on the menu screen OFF 8x 01 04 06 06 03 FF Turn off the menu screen IR_Receive...

Page 43: ...d Command Function Command packet Note CAM_PowerInq 8x 09 04 00 FF y0 50 02 FF On y0 50 03 FF Off Standby CAM_ZoomPosInq 8x 09 04 47 FF y0 50 0p 0q 0r 0s FF pqrs Zoom Position CAM_FocusAFModeInq 8x 09...

Page 44: ...orSaturationInq 8x 09 04 49 FF y0 50 00 00 00 0p FF p Color Gain setting 0h 60 to Eh 130 CAM_IDInq 8x 09 04 22 FF y0 50 0p FF p Gamma ID IR_ReceiveInq 8x 09 06 08 FF y0 50 02 FF On y0 50 03 FF Off IR_...

Page 45: ...eed SUM DownLeft 0xFF Address 0x00 0x14 Pan Speed Tilt Speed SUM DownRight 0xFF Address 0x00 0x12 Pan Speed Tilt Speed SUM Zoom In 0xFF Address 0x00 0x20 0x00 0x00 SUM Zoom Out 0xFF Address 0x00 0x40...

Page 46: ...0xAF XOR Call Preset 0xA0 Address 0x00 0x07 0x00 Preset ID 0xAF XOR Query Pan Position 0xA0 Address 0x00 0x51 0x00 0x00 0xAF XOR Query Pan Position Response 0xA0 Address 0x00 0x59 Value High Byte Valu...

Page 47: ...12Gbit s bitrate and able to support 2160p 60 U SDI Technology for transmitting large volume 8K signals over a single cable a signal interface called the ultra high definition signal data interface U...

Page 48: ...cations where high power must be transmitted Single mode Fiber Fiber that support a single mode are called single mode fibers Single mode fibers are used for most communication links longer than 1 000...

Page 49: ...nterlaced video signals PAL Phase Alternate Line A television standard in which the phase of the colour carrier is alternated from line to line It takes four full images 8 fields for the colour to hor...

Page 50: ...l RTMP was initially a proprietary protocol developed by Macromedia now Adobe for streaming audio video and data over the Internet between a Flash player and a server RTSP The Real Time Streaming Prot...

Page 51: ...io of 30 1 to 50 1 Colour Temperature The colour quality expressed in degrees Kelvin K of a light source The higher the colour temperature the bluer the light The lower the temperature the redder the...

Page 52: ...l image within a larger image created by scaling down one of image to make it smaller Other forms of PIP displays include Picture By Picture PBP and Picture With Picture PWP which are commonly used wi...

Page 53: ...Science Technology Co Ltd excepting where noted RGBlink is a registered trademark of Xiamen RGBlink Science Technology Co Ltd While all efforts are made for accuracy at time of printing we reserve the...

Reviews: