General Cautions
During operation there must be a separation distance of 20cm between all persons and the antenna.
Ensure that all used RF connectors are secure and properly terminated.
When used in the US - FCC Caution
Caution: The user is cautioned that changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15
of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following
measures:
—
Reorient or relocate the receiving antenna.
—
Increase the separation between the equipment and receiver.
—
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
—
Consult the dealer or an experienced radio/TV technician for help.
This equipment complies with FCC’s RF radiation exposure limits set forth for an uncontrolled environment. The antenna(s)
used for this transmitter must be installed and operated to provide a separation distance of at least 20 cm from all persons
and must not be collocated or operating in conjunction with any other antenna or transmitter. Installers must ensure that
20cm separation distance will be maintained between the device (excluding its handset) and users.
When used in Canada - ISED Caution
This device complies with RSS 210 of the Industry Canada Rules. Operation is subject to the following two conditions:
(1) this device may not cause interference, and (2) this device must accept any interference, including interference that may
cause undesired operation of the device.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence.
L’exploitation est autorisée
aux deux conditions suivantes :
(1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage
radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.
This equipment complies with Canada radiation exposure limits set forth for uncontrolled environments. This equipment
should be installed and operated with a minimum distance of 20cm
(
may be adjusted according to actual calculation
result
)
between the radiator and your body.
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Déclaration d’IC sur l’exposition aux radiations:
Cet éq
uipement est conforme aux limites d’exposition aux radiations définies par le Can
ada pour des environnements non
contrôlés. Cet équipement doit être installé et utilisé à une distance minimum de 20 cm entre l’antenne et votre corps.
Cet émetteur ne doit pas être installé au même endroit ni utilisé avec une autre antenne ou un autre émetteur
Acceptable Antennas
This device has been designed to operate with the antenna(s) listed below and having a maximum gain of 3 dBi. Antennas not
included in this list or having a gain greater than 3 dBi are strictly prohibited for use with this device. The required antenna
impedance is 50 ohms.
Acceptable antenna – 3dBi RFD whip.