background image

SCORPION LoRa Transmitter 

Disclaimer: 
Whilst the information in this document is believed to be correct at the time of issue, RF Solutions Ltd does not accept any liability whatsoever for its accuracy, adequacy or 

completeness. No express or implied warranty or representation is given relating to the information contained in this document. RF Solutions Ltd reserves the right to make 

changes and improvements to the product(s) described herein without notice.  Buyers and other users should determine for themselves the suitability of any such infor-
mation or products for their own particular requirements or specification(s).  RF Solutions Ltd shall not be liable for any loss 

or damage caused as a result of user’s own 

determination of how to deploy or use R F Solutions Ltd’s products.  Use of RF Solutions Ltd products or components in life s

upport and/or safety applications is not author-

ised except with express written approval. No licences are created, implicitly or otherwise, under any of RF Solutions Ltd’s 

intellectual property rights. Liability for loss or 

damage resulting or caused by reliance on the information contained herein or from the use of the product (including liability resulting from negligence or where RF Solutions 
Ltd was aware of the possibility of such loss or damage arising) is excluded. This will not operate to limit or restrict QuasarU

K Ltd’s liability for death or personal injury 

resulting from its negligence. 

Technical Specifications 

 

 

“W” version with Wireless Charging (Fixed Internal Rechargeable Battery) 

 

Enclosure Rating:  IP65  
Battery Type:  Internal Lithium Polymer 980mAH 
The Batteries are fixed internal are not removeable 
 

Electrical Characteristics 

Min 

Typical 

Max 

Units 

Supply Voltage 

 3.3 

4.5 

5  

Frequency: 

 

 

869.500 
918.000 

 

MHz 

RF Output Power (ERP) @ 869.50 MHz 

22 

 

dBm 

Important European compliance information  

This RF Solutions product meets the essential requirements of the European Radio Equipment Directive 

2014/53/EU and has been tested to European Harmonised Standards and CE marked accordingly. A copy 

of the EU Declaration of Conformity can be located on the RF Solutions Website, 
 

www.rfsolutions.co.uk/certification-i59

. 

RF Solutions Ltd. Recycling Notice 
Meets the following EC Directives: 
DO NOT 
Discard with normal waste, please recycle. 
ROHS Directive 2011/65/EU and amendment 2015/6863/EU 
Specifies certain limits for hazardous substances. 
WEEE Directive 2012/19/EU 
Waste electrical & electronic equipment. This product must be disposed of 

through a licensed WEEE collection point. RF Solutions Ltd., fulfils its WEEE 

obligations by membership of an approved compliance scheme, environment 

agency registration number WEE/JB0104WV.

 

Waste Batteries and Accumulators  
Directive 2006/66/EC 
Where batteries are fitted, before recycling the 

product, the batteries must be  
removed and disposed of at a licensed  
collection point. 
RF Solutions battery producer number 

BPRN00060.

 

 

Summary of Contents for SCORPION Series

Page 1: ...ed internal Lithium Battery which is recharged using standard QI wireless charger base Rugged RF Transmitter Handset Supplied Ready to Go 1 16 Switches 868 918MHz Versions FM LoRa Technology Range LOR...

Page 2: ...ORPION 1 Page 2 Part Numbers Transmitter 868MHz Europe 915MHz USA Aus UK 1 Switch SCORPION 8TW1 SCORPION 9TW1 4 Switch SCORPION 8TW4 SCORPION 9TW4 8 16 Switch SCORPION 8TW16 SCORPION 9TW16 Mechanical...

Page 3: ...nnels Relay changeover contact outputs expandable to 250 using add on Relay modules 12 30Vdc supply PRO Series Receiver Units IP65 Receiver with DIN Rail Modules 4 8 16 Channels Changeover Contacts ex...

Page 4: ...ver The RED LED will Flash at high speed to indicate that an acknowledgment has not been received back form the receiver Low Battery If battery requires recharging Low Battery LED illuminates for 3 se...

Page 5: ...D2 LED3 Flashes constantly in setup Restore SCORPION to Factory Default Setings Briefly Press SET Sw LED1 ON Constantly Press Hold SET Sw For 10 Secs The Following Modes can be configured using the SE...

Page 6: ...Mode 2 4x LORA Mode 3 5x LORA Mode 4 6x LORA Mode 5 7x LORA Mode 6 8x LORA Mode 7 After selecting wait for timeout Wait 3 Seconds Wait 3 Seconds To Set the RF Transmission MODE Notes 1 Range is depen...

Page 7: ...ther ON or OFF indicating current Status Press SET Sw To select LED1 ON Acknowledgement LED1 OFF NO Acknowledgement After selecting wait for timeout Wait 3 Seconds Wait 3 Seconds To Set Acknowledgemen...

Page 8: ...in range and the system is operating correctly When using Watchdog it may be useful to incorpo rate a Power Switch to avoid premature battery discharge A power switch can be incorporated If this is re...

Page 9: ...a SCORPION Button State Change Transmit SCORPION transmits an RF transmission only when the switch button is pressed or released i e a state change On each of these state changes SCORPION trans mits...

Page 10: ...then RX ack Flashes if no Ack received Button is released Flashes briefly TX then RX ack Flashes if no Ack received State Change Transmission Acknowledgement OFF Operation GREEN LED RED LED Button is...

Page 11: ...strict QuasarUK Ltd s liability for death or personal injury resulting from its negligence Technical Specifications W version with Wireless Charging Fixed Internal Rechargeable Battery Enclosure Ratin...

Reviews: