background image

CARLTON FM/LoRa Transmitter 

DS-CARLTON-2 Page  10 

Technical Specifications 

Enclosure Rating: 

IP67 

Battery Type: Lithium Polymer 3.7V 980mAH  
Operating Temperature 

10 to +60 

o

Electrical Characteristics

 

Min

 

Typical

 

Max

 

Units

 

Supply Voltage 

 3.0 

4.5 

5  

Frequency: 

 

 

869.500 
918.000 

2400 

 

MHz 

RF Output Power (ERP)  

869.50MHz 
918MHz 
2.4GHz 

 
 

 

 

+22 
+22 
+14 

dBm 

SUPPLIER’S DECLARATION OF CONFORMITY

 

This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions: (1) This   

device may not cause harmful interference, and (2) this device must not accept any interference received , including 

interference that may cause undesired operation. 

 

47 CFR 2.1077 Compliance Information 

This Declaration of Conformity is hereby issued according to Chapter 1, Subpart A, Part 2 of Title 47 of the code of 

Federal Regulations by: 

RF Solutions Limited 

William Alexander House  
William Way  
Burgess Hill  
West Sussex 
RH15 9AG 
United Kingdom 

 

 

Contains FCC ID: P9OLAMBDA62 

Complies with FCC Part 15.247 

 

United States Responsible Party 

Violette Engineering Corporation, 6731 Whittier Avenue, McLean, VA 22101 

[email protected] 

The  responsible  party  warrants  that  each  unit  of  equipment  marketed  under  this  Declaration  of  Conformity  will  be 

identical to the unit tested and found acceptable with the standards and that the records maintained by the respon-

sible party continue to reflect the equipment being produced under such Supplier’s Declaration of Conformity contin-

ue to comply within the variation that can be expected due to quantity production and testing on a statistical basis. 

 

Australia SRD Certification (918MHz versions) 

At the  time of writing the CARLTON is at the Test lab undergoing approvals testing. This is expected to 
be completed during 2021.  

Trade Name 

 

Model

 

RF Solutions LoRa Carlton

 

 

CARLTON-9T16 

Summary of Contents for CARLTON-8T16

Page 1: ...n can operate in several Modes of operation providing short or longer range It can be optionally set to request feedback from the receiver to provide the user with visual feedback and can also provide...

Page 2: ...0Vdc supply 725 DIN Rail Module DIN Rail Receiver 2 Channels Relay changeover contact outputs expandable to 250 using add on Relay modules 12 30Vdc supply GAMMA OEM RF Module RF module with 8 Digital...

Page 3: ...indicate the following RF Transmit GREEN LED operates when CARLTON is transmitting an RF signal RF Acknowledge if configured GREEN LED will Flash at high speed to indicate that an acknowledgment has s...

Page 4: ...charged via the USB connector or using a wireless charging pad When Charging the Battery RED LED gives a slow Flash indicates charging is in progress When fully charged the GREEN LED is illuminated Re...

Page 5: ...hes constantly in setup The Following Modes can be configured using the SET Switch 1 RF Mode of Transmission FM or LORA Mode 2 Acknowledgement back from the Receiver 3 Automatic Watchdog Transmissions...

Page 6: ...RA Mode 2 4x LORA Mode 3 5x LORA Mode 4 6x LORA Mode 5 7x LORA Mode 6 8x LORA Mode 7 After selecting wait for timeout Wait 3 Seconds Wait 3 Seconds To Set the RF Transmission MODE Notes 1 Range is dep...

Page 7: ...2X LED1 flashes 2x LED 1 2 Flashes 1x LED1 is either ON or OFF indicating current Status Press SET Sw To select LED1 ON Acknowledgement LED1 OFF NO Acknowledgement After selecting wait for timeout Wa...

Page 8: ...in range and the system is operating correctly When using Watchdog it may be useful to incorpo rate a Power Switch to avoid premature battery discharge A power switch can be incorporated If this is r...

Page 9: ...n a CARLTON Button State Change Transmit CARLTON transmits an RF transmission only when the switch button is pressed or released i e a state change On each of these state changes CARLTON trans mits up...

Page 10: ...Federal Regulations by RF Solutions Limited William Alexander House William Way Burgess Hill West Sussex RH15 9AG United Kingdom Contains FCC ID P9OLAMBDA62 Complies with FCC Part 15 247 United States...

Page 11: ...utions co uk FI RF Solutions Limited vakuuttaa ett radiolaitetyyppi Carlton 8T16 on direktiivin 2014 53 EU mukainen EU vaatimustenmukaisuusvakuutuksen t y simittainen teksti on saatavilla seuraavassa...

Reviews: