Form I-RA/D 140/235 (Version A), Mfg No. 110318 Rev 4, Page 41
Troubleshooting
Continued
Check for line
voltage across Terminals
5 and 2. Is voltage
read?
Check for line
voltage across Terminals
13 and 11. Is voltage
read?
*Is burner
motor reset button
tripped?
Reset and check
for proper
operation.
Replace burner
motor.
Replace fuse.
Replace ignition
controller.
YES
NO
YES
NO
YES
NO
Chart No. 2 - Thermostat calling for heat,
burner motor never attempts to run (green
light is lit) indicating “System Ready”. Chart
No. 1 has been successfully completed.
NOTE:
After ignition control is reset, you will have 30 SECONDS to
perform the tests shown below before the controller locks out.
Reset ignition control:
Press the RED BUTTON, hold for four sec-
onds, and release. DO NOT RESET MORE THAN ONE TIME.
*Reset button on the motor activates when the motor is over-
heated. Motor amp draw must be less than the full load amps on
the motor rating plate. Verify the motor is operating correctly.
Refer to illustra-
tion on page 38.