14.4.7 Communication parameter configuration
Communication related parameter settings
Parameter
Name
Parameter settings
E0.00
First frequency setting source
20: Communication
E0.01
First run command source
2: Communication
E0.02
Second frequency setting source
20: Communication
E0.03
Second run command source
2: Communication
E8.00
Communication protocol
1: Extension card
E8.03
Communication process data loss be-
havior
Depends on parameter setting
①
H1.00
PROFIBUS local address
H1.01
Present baud rate
(Read only)
H1.02
Present telegram type
H1.10
Output PZD 1
Depends on parameter setting
①
H1.11
Output PZD 2
H1.12
Output PZD 3
H1.13
Output PZD 4
H1.14
Output PZD 5
H1.15
Output PZD 6
H1.16
Output PZD 7
H1.17
Output PZD 8
H1.18
Output PZD 9
H1.19
Output PZD 10
H1.30
Input PZD 1
H1.31
Input PZD 2
H1.32
Input PZD 3
H1.33
Input PZD 4
H1.34
Input PZD 5
H1.35
Input PZD 6
H1.36
Input PZD 7
H1.37
Input PZD 8
H1.38
Input PZD 9
H1.39
Input PZD 10
Tab. 14-39: PROFIBUS-DP communication parameters
①
: See
chapter "H1: PROFIBUS card parameters" on page 357
for
details.
EFC x610 Series
Bosch Rexroth AG
Communication
DOK-RCON03-EFC-X610***-IT05-EN-P
283/389