Rexroth EcoDrive Cs Drives
Electrical Connections
5-3
DOK-ECODR3-DKC**.3-CS*-PR02-EN-P
Schematic Overall Connection Diagram
anschlussplan_gesamt_en.fh7
TX
RX
S20
2
1
ON
X4
X5
X6
W
V
U
RB2
RB3
RB1
DL2
DL1
L2C
L1C
L3
L2
L1
9
8
7 6 5 4
3
2
1
9
8
7 6 5 4
3
2
1
ADDRESS
NODE
0
0
Rexroth
ECODRIVE Cs
S1
H1
S2
S3
LINE ERROR
X20
X21
X4
X5_3
X5_2
X5_1
INPUTíF200V
-240V
X3
X2
X1
X6
braking
resistor
RS232
master
communication
encoder
cable
motor cable
L1
L2
L3
L1C
L2C
RB1
RB2
U
0V
W
Ground
Shield
voltage supply
of holding brake
24V
BR+
BR-
V
trans-
former
L1 L2 L3
L1
N (1ph)
(3ph)
necessary, when mains voltage > 240 V
necessary
magnetic
contactor
optional
RB3
mains
filter
Fig. 5-4:
Schematic overall connection diagram
Concerning description of connections: see table on page 5-1.
Concerning cables: see chapter 10.1
Courtesy