background image

11

Top

Left

(A)

Right

(B)

(C)

(D)

(E)

(F)

(G)

(H)

(I)

(J)

Summary of Contents for PJ2-COM RADIO

Page 1: ...Operator s Manual 8819PS...

Page 2: ...quency Electromagnetic Fields 3 kHz to 300 GHz ANSI IEEE C95 3 1992 IEEE Recommended Practice for the Measurement of Potentially Hazardous Electromagnetic Fields RF and Microwave When transmitting hol...

Page 3: ...ions 1 Install the batteries 2 Turn the unit on rotate volume knob clockwise 3 Enter the desired frequency 1 2 2 9 7 5 for 122 975 MHz Note Six digits may be required to select certain frequencies 4 L...

Page 4: ...ront View 12 Back View 12 Operating Instructions Manual Frequency Selection 14 Frequency Search 15 Frequency Memory 16 Memory Recall 18 Memory Scan 19 Memory Clear 20 Transmitting 21 Key Lock 22 Scree...

Page 5: ...ing features Standard Twin Plug Aviation Headset Jacks Accepts USB Type C Power 2 4 amps 760 COMM frequencies 118 000 MHz to 136 975 MHz Auto Lit Keypad and Screen 20 Visual Memory Channels Full Featu...

Page 6: ...d under this warranty return it postage paid with proof of purchase to Sporty s Pilot Shop 2001 Sporty s Dr Clermont County Sporty s Airport Batavia Ohio 45103 9747 If your PJ2 COM is no longer under...

Page 7: ...und at the bottom of the battery pack Remove the battery cover by sliding it up Six 1 5 volt AA Alkaline batteries are required Replace the batteries by following the positive and negative terminal ma...

Page 8: ...ly shorted Use only the approved external power adapters and battery packs Never touch an external antenna when the danger of lightning is present Do not leave the transceiver near heat sources such a...

Page 9: ...9 Page intentionally left blank...

Page 10: ...n to turn the unit on and to increase volume Turn the knob counterclockwise to decrease volume and to turn the unit off F Wrist Strap Attachment point A wrist strap can attach to this location Left Si...

Page 11: ...11 Top Left A Right B C D E F G H I J...

Page 12: ...ith the UP Key to enable disable the BEEP function This Key is also used in combination with the ON OFF Volume Control to clear all memory channels Q Internal Speaker R Weather Key This key is used to...

Page 13: ...ding the clear key and pressing the 8 key AA 9 Key LED Contrast This key is used to adjust the LCD contrast and night mode function This is accessed by holding the clear key and pressing the 9 key Bac...

Page 14: ...ch as 118 700 MHz enter 1 1 8 7 0 0 using the numeric keypad As each digit is entered the flashing cursor moves to the next digit Six digits may be required to select a frequency The PJ2 COM will retu...

Page 15: ...ting signal is cut off for more than two seconds the Search will resume until another signal is found When 136 975 MHz is reached during a upward Search the Search automatically continues at 118 000 M...

Page 16: ...uch as 122 700 to be stored by using either manual frequency selection or frequency search To store this frequency press the Memory Key The following screen will appear The first available memory chan...

Page 17: ...ry channel is already storing a frequency the stored frequency will be displayed next to the memory channel number on the screen while your selected frequency remains on the top line Once the desired...

Page 18: ...Recall Key followed by 0 8 Once in the Recall function the PJ2 COMM stays in Recall until the Clear Key is pressed This allows you to sequence your frequencies in the order you may wish to use them Fo...

Page 19: ...und The Scan may be canceled at any time by pressing the Clear Key The direction of the Scan may also be reversed at any time by pressing and holding the Up or Down Key whichever is appropriate for on...

Page 20: ...nnels to select the memory channel to clear Once the desired memory channel is displayed press the Memory Clear Key also the 0 Key on the Numeric Keypad to clear the selected channel Additional channe...

Page 21: ...splay TX beneath the frequency to verify the PJ2 COM is broadcasting Release the PTT to end the transmission and the PJ2 COM will once again receive the selected COMM frequency If a headset is being u...

Page 22: ...lt To save battery life you may deactivate the backlighting Press and release any button to activate the PJ2 COM s screen and keypad lighting for five seconds Screen and keypad lighting will also acti...

Page 23: ...Key followed by the Up or Down Key to scroll to 08 Or 2 Press the Recall Key followed by 8 Once in the Weather Band function the PJ2 COM stays in Weather Band until the Clear Key is pressed While in...

Page 24: ...save the setting LCD Contrast Adjustment To adjust the LCD contrast of the PJ2 COM press the clear key and the 9 key The contrast can be adjusted by pressing the up or down keys Press the clear key t...

Page 25: ...25 Page intentionally left blank...

Page 26: ...9 Weight with Alkaline Battery Pack including antenna 1 12 lb 508 grams Weight without battery pack including antenna 72 lb 327 grams Dimensions with battery pack Height 6 9 in 175 95 mm Width 2 4 in...

Page 27: ...0 mW into 8 Ohms 10 Sensitivity 2 0 uV 1 kHz Modulation 30 Band Width 25 KHz at 60 dB down Transmitter Transmitter Power 1 5 Watts 20 5 Watt PEP at 85 modulation Spurious Radiation 60 dB below carrier...

Page 28: ...Custom Manufactured by Rexon for Sporty s Pilot Shop 2001 Sportys Drive Batavia OH 45103 Made in Taiwan 1812A Sportys com...

Reviews: