* Install the heater on a non-flammable surface.
* Protect the heater from water spatter.
* Always ensure the condition of the power cord. Do not bend the cord, and ensure that it is not crushed
under or between anything. A damaged power cord or plug may cause a short circuit, electrical shock and
even fire.
* If the Rexener water heater’s power cord is damaged, it must be immediately replaced with a new one at
a maintenance shop authorised by the manufacturer or importer, or in some other authorised provider of
electrical repair services.
* Do not extend the power cord by connecting additional lengths of cord to it or its connector plugs.
Poorly-made connections may cause a short circuit, electrical shock and/or fire.
* If the plug gets dirty, clean it carefully before connecting it to the socket. A dirty plug may cause a failure
and, as the dirt is heated, smoke, a short circuit and even fire may result.
* Before cleaning and maintaining the device, disconnect the power plug from the socket and allow the
device to cool down sufficiently. Neglecting these instructions may lead to burns or an electrical shock.
* During thunder, deactivate the device and disconnect the power plug from the electrical grid.
CONTENT OF THE REXENER WATER HEATER
•
Rexener Water Heater
•
Fuel tank
•
Rexener water heater’s water circuit connections for water hose (1.5 mm external thread, 2 pcs).
•
Plugs for the Rexener water heater’s water circuit (2 pcs).
•
Sealing tape for the threads of the water circuit connection (1 roll).
•
Water heater drainage valve.
•
Chimney pipe (1 pcs) and cap (1 pcs)
•
Instruction manual
•
Key for heater door
INSTALLING THE REXENER WATER HEATER
• The Rexener water heater must be installed in a visible location that can be easily monitored.
• Do not install the heater in a location where it is subjected to significant heat or continuous moisture.
• Ensure sufficient room around the heater for maintenance and operation.
• The manufacturer’s recommendation is 60 cm from fixed structures.
• Clear the immediate vicinity of the heater of flammable materials or structures, wood piles, wooden walls
or roofs, piles of leaves or twigs, etc.
• In operating conditions, the Rexener water heater weighs approx. 43 kg. Prepare a sufficiently solid and
strong foundation for the heater with concrete tiles, for example. Remember to counteract the effects of
frost heave. Remove loose soil from under the tiles and replace it with gravel up to a depth of about 20cm.
• Do not position the heater on an unstable, inclined or wobbly foundation. The device tilting and / or falling
over may cause malfunctions and lead to a fire.
• Install the heater on a non-flammable surface or otherwise ensure that the surface is fireproof.
• Install the heater on a non-flammable surface.
• The heater’s legs are adjustable. Use them to ensure that the heater is level.