When  use  the  round  coil 

14”  (36cm.):

  The  bearing  rod  is  assembled  by  inserting  of  the 

lower part into the upper one. Choose the desired length of the whole construction and the 

fixing  clamp  is  tightened  between  both  parts  of  the  bearing  rod.  The  lower  part  of  the 

bearing  rod  is  put  with  the  opening  between  the  ears  of  the  coil  and  the  plastic  bolt  is 

tightened  by  choosing  the  position  of  the  coil  to  be  parallel  to  the  ground  surface.  Don't 

over-tighten the plastic bolt and nut to not damage the threading of the bolt! The coil cable 

is wind up tightly around the bearing rod and is switched to the terminal of the monitor unit. 

Upon switching of the cable of the coil to the monitor unit, tighten the well the metal nut of 

the coupling to the terminal of the box. Upon switching off, unscrew the nut completely and 

pull  out  the  coupling  without  pulling  or  twisting  the  cable  of  the  coil.  This  way,  you  will 

prevent the cable and the conductors in it from breakdown or short circuit.  Fi nall y  adjust  

s e a r c h   c o i l   a n g l e   t o   yo u r   p r e f e r e n c e   a n d   y o u   ar e rea dy.

   

NOTE

: Do not allow the cable to flop loosely over the search coil. Since the detector 

is sensitive enough to „see“ the tiny wires in the cable, a floppy cable can cause false 

signals as the search coil senses the moving wires. 

 

 

When  use  the  search  frames  1x1m.  or  bigger:

  The  search  frame  should  be  held 

approximately  4  to  6  inch  (10  to  15cm.)  to  ground  surface

  while  searching.  Do  not 

allow  one  end  of  the  frame  to  be  higher  than  the  other.  Make  sure  that  no  large  metal 

objects  are  close  to  the  search  frame  for  initial  adjustment.  Also,  check  your  shoes  or 

boots since most of them contain metal parts and you would receive a signal response any 

time you step near to the coil.  

In order to avoid interference of the metal parts of the electronic unit, be sure to carry the 

Pulse Master Pro

 on the side of your body that is away from the search frame. 

 

1

Setting and use

 

VEGA

Searching  frame  is  assembled  and  is  placed  on  the  ground  paying  attention  to  the  range 

and there don't have to be any metal objects. The cable is sub - connected to the device. 

Turn on the detector by 

rotating “

VOLUME

” knob clockwise to "

ON

" position  

 

Summary of Contents for Vega

Page 1: ...1 REX TM Metal Detectors V E G A pulse induction metal detector User s guide ____________________________ www rexmetaldetectors com ____________________________ Made in Bulgaria ...

Page 2: ...ed to adjust threshold level Rotate the controller counter clockwise to low position to avoid interference Clockwise rotate the controller to have high hum level DELAY sampling delay control knob GND DISC dual control knob adjust ground balance in ALL METAL mode and discrimination in DISC mode Button DISC switch on and switch off DISC mode Button MODE toggling between Dynamyc and Static modes Butt...

Page 3: ...it Finally adjust search coil angle to your preference and you are ready NOTE Do not allow the cable to flop loosely over the search coil Since the detector is sensitive enough to see the tiny wires in the cable a floppy cable can cause false signals as the search coil senses the moving wires When use the search frames 1x1m or bigger The search frame should be held approximately 4 to 6 inch 10 to ...

Page 4: ...SC knob In ALL METAL mode this knob working as ground balance control Lower the search frame coil to within one inch of the ground surface while listening to the threshold audio signal If the threshold signal increase the GND DISC control needs to be increased to high position At the same time you can increase DELAY too to high position When DELAY knob is in low to middle positions 1 5 detector wi...

Page 5: ...tion Don t set the THRESHOLD to high position Or you ll get a false result Also low sensitivity usually used when a large object is detected at a small depth in earth Then the signal is continuous in order to determine the exact place of the object it is more convenient to use low sensitivity Thus the signal from the detected object becomes much shorter VEGA can sometimes react by small objects su...

Page 6: ... less than the maximum depth but at the same time can be eliminated large iron ferrous objects You can set your preference discrimination as to what extent be rejected iron magnetic objects Recommended to work as DISC is 8 In this case loss of depth is not as tangible while successfully eliminating most magnetic objects When the frame moves over a ferrous object the sound level does not change and...

Page 7: ...n do field tests by yourself using the device if you bury different metal objects in different depth but you should leave them in the ground for at least 3 months Thus the test results will be more reliable You should mind the soil type and the moisture composition in it Best results are received when the soil is dry 5 Charging storage batteries and indications for their status VEGA has a built in...

Page 8: ... battery If it is under 12V charge the batteries with the automatic charger If you can not solve the problem contact the service station office of the company manufacturer or the local distributor 6 3 During detection the device does not work stable makes strange sounds which are not due to a metal detection It might indicate for irregular electromagnetic external interruptions problems with the a...

Page 9: ...EGA has been exposed to low temperatures you should absolutey avoid an abrupt warming The condensation humidity can provoke a disturbance of function 7 Guarantee The detector VEGA is offered with 2 years of guarantee of electronics labor and materials used for harms which are not caused on purpose or irresponsibly We can upkeep your device after period of guarantee if it is necessary The Manufactu...