background image

19

Part 1 - INSTALLATION INSTRUCTIONS

4.4  -  Ducting  or  recirculation  fitting

1 - Ducting fitting.

This is possible for all forms of installation:

a) Connect the air outlet to the external ducting system.
b) Remove the activated charcoal filter (if there is one) inside the

hood canopy (see Maintenance).

2 - Recirculation fitting

This is only possible with the air outlet directed upwards. Fit the
venting grille 

G

 onto the air outlet (

Fig. 25

). The activated charcoal

filter should be fitted inside the hood canopy after connection to
the power supply.

4.5  -  Connection  to  power  supply  and  checking  of  good

working  order

1 - It  is  absolutely  necessary  to  follow  the  warnings  3.2,  3.3  and  3.4  of  paragraph  3,

concerning safety measures.

2 - Loosen the two locking screws and remove the metal cover 

(fig.26).

Connect the hood connection to the engine connection 

(fig.27a).

 Correctly place the

connectors under the cover and tighten the two locking screws 

(fig. 27b)

.

3 - Once electrical connection has been carried out, check that lights, engine and change

of speed work

4 - Fit the lower grill and the activated carbon filter (only for filter mode) (see Maintenance).

27b

S36_27

27a

S07_23

25

S36_26

26

Summary of Contents for CA 962 ALU

Page 1: ...Cappa Aspirante Cooker hood CA 962 ALU ...

Page 2: ...celta del tipo di installazione Selecting the type of installation Installazione del corpo cappa C Installation of the hood canopy C Installazione del camino A Installation of the chimney A Connessione Aspirante o Filtrante Ducting or recirculation fitting Connessione Elettrica e Controllo Funzionale Connection to power supply and checking of good working order ...

Page 3: ...ze per la Sicurezza 11 Safety Warnings 20 Uso 11 Operation 20 Manutenzione 11 Maintenance 20 Filtri antigrasso metallici Metal antigrease filters Filtri al carbone attivo Activated carbon filters Illuminazione Light Pulizia Cleaning ...

Page 4: ...ducting spigot R 2 6 No 1 support rod B 2 7 No 1 fixing kit containing No 1 wall bracket S to fix the canopy hood No 1 cover D screws rawl plugs and documentation 3 SAFETY WARNINGS 3 1 When used in the extraction mode the cooker hood ducting must not be connected to a flue which is used for exhausting fumes from appliances supplied with energy other than electric such as a central heating flue or ...

Page 5: ...t on this hood enables it to be installed in one of four different ways 1 Air outlet directed upwards ducting or recirculation fitting 2 Air outlet directed towards the wall ducting fitting only 3 Air outlet directed to the right or left ducting fitting only For correct installation of the hood please proceed in the following stages 4 1 Selection of the type of installation 4 2 Installation of the...

Page 6: ...g the extension Z of the chimney required for installation plus 18 mm X Z 25 7 Using a Ø8 mm drill bit drill the points marked in this way b When installed with the air outlet directed towards the wall fig 5a it will be necessary to drill an air ducting opening measuring Ø120 or 150 mm according to the diameter of the flange F provided 2 Fitting the fixing elements a Insert the rawl plugs provided...

Page 7: ...e hooks at the rear of the hood which can be used to adjust its position as follows Turn the screws L until the position of screws N coincides with the lower access holes Turn the screws N to adjust the vertical and horizontal position of the hood Lock the screws L to fasten the hood against the wall Insert the plugs T provided in the holes giving access to screws N 4 3 Installation of the chimney...

Page 8: ...position of the ducting fan unit a The hood is normally supplied with the air outlet directed towards the wall fig 3 if it is to be installed with the air outlet directed to the right or left fig 4a b it will be necessary to change the direction of the ducting fan unit proceeding as follows Unscrew the screws U fig 14 Turn the ducting fan unit 60 to the right or left Replace the screws U b The duc...

Page 9: ...parts of the chimney and pull the inner section I fig 20 almost all the way out Remove the protective film P b Rest the lower section of the chimney in its housing on the top of the hood canopy Lower the ducting fan unit until it reaches the wall bracket S and fix it using the screw H provided fig 21 Fit the cover D provided on the wall bracket S fig 22 c Fix the chimney A to the hood canopy C usi...

Page 10: ...ide the hood canopy after connection to the power supply 4 5 Connection to power supply and checking of good working order 1 It is absolutely necessary to follow the warnings 3 2 3 3 and 3 4 of paragraph 3 concerning safety measures 2 Loosen the two locking screws and remove the metal cover fig 26 Connect the hood connection to the engine connection fig 27a Correctly place the connectors under the...

Page 11: ... flame from licking round from the bottom of the pan this will save energy and will avoid a dangerous concentration of heat 1 4 Always ensure that the appliance is used in accordance with the manufacturer s instructions for the removal of contaminated air and odours during cooking 2 OPERATION Control panel fig 28 The cooker hood can be operated as follows BUTTON L Turns the lighting system on and ...

Page 12: ...ers and the activated carbon filter from its seat by acting on the hooks G1 fig 30 Fit the new activated carbon filter and the metal antigrease filters WARNING Maintenance or replacement periods should be respected to avoid any fire hazards when the filters get saturated with grease 3 3 Light 1 It consists of 2 20 W halogen spotlights 2 Replacement fig 31 Remove the two screws that lock the metal ...

Page 13: ...22 ...

Page 14: ...23 ...

Page 15: ...4329410_02 040122 ...

Reviews: