REWIRE SECURITY DB3 User Manual Download Page 64

Response 
details 

 

Description 

 

GNSS  

Indicates valid (1) or invalid (0) GNSS data  

Sat  

Count of currently available satellites  

Lat  

Latitude (Last good Latitude)  

Long  

Longitude (Last good Longitude)  

Alt  

Altitude  

Speed  

Ground speed, km/h  

Dir  

Ground direction, degrees  

Date  

Current date  

Time  

Current GMT time  

  

Example

:  GNSS:1 Sat:7 Lat:54.71473 Long:25.30304 Alt:147 Speed:0 

Dir:77 Date: 2007/8/24 Time: 13:4:36  

6.1.7  Getinfo  

 

Response details 

 

Description 

 

INI  

Device Initialization Time   

RTC  

RTC Time  

RST  

Restart Counter  

ERR  

Error Counter  

SR  

Number of Sent Records  

BR  

Number of broken records  

CF  

Profile CRC Fail counter  

FG  

Failed GPRS counter  

Summary of Contents for DB3

Page 1: ...DB3 Plug Play GPS Tracker User Manual ...

Page 2: ...Card Into DB3 Plug Play Device 15 3 2 Installing DB3 Plug Play Drivers 17 3 3 Navigate LED 19 3 4 Status LED 19 3 5 ODB II 19 3 6 USB 21 4 Firmware 22 4 1 Updating Firmware Using USB Cable 22 5 Operational Basics 23 5 1 Operational Principals 23 5 2 Sleep Modes 24 5 2 1 Sleep Mode 24 5 2 2 Deep Sleep Mode 24 5 3 Virtual Odometer 26 5 4 Features 26 5 4 1 Scenarios 26 5 4 2 Trip 27 5 4 3 Geofencing ...

Page 3: ...ogeofencing Settings 48 5 12 I O Settings 50 5 12 1 Event Generating 53 5 12 2 Hysteresis 54 5 13 OBD Functionality Description 55 5 13 1 Supported OBD Protocols 55 5 13 2 Data 55 5 13 3 Fuel Consumption Calculation 58 5 14 Accelerometer 59 6 SMS Command List 59 6 1 SMS Command List 60 6 1 1 Getstatus 61 6 1 2 Getweektime 62 6 1 3 Getops 62 6 1 4 Getcfgtime 63 6 1 5 Ggps 63 6 1 6 Getgps 63 6 1 7 G...

Page 4: ...witch Source ID 1002 76 9 2 4 Ignition Source ID 1003 76 9 2 5 Static navigation settings ID 1004 77 9 2 6 Saving Sending without time synchronization ID 1005 77 9 2 7 Power Voltage Low Level ID 1006 77 9 2 8 Power Voltage High Level ID 1007 78 9 2 9 LED Indication ID 1008 78 9 2 10 Battery charge mode ID 1009 78 9 3 Records Parameters 79 9 3 1 Sorting ID 1010 79 9 3 2 Active Data Link Timeout ID ...

Page 5: ...ode Vehicle on STOP Parameters 86 9 5 2 Home Network GSM Operator Code Vehicle MOVING Parameters 88 9 5 3 Roaming Network GSM Operator Code Vehicle On STOP Parameters 91 9 5 4 Roaming Network GSM Operator Code Vehicle MOVING Parameters 92 9 5 5 Unknown Network GSM Operator Code Vehicle On STOP Parameters 94 9 5 6 Unknown Network GSM Operator Code Vehicle MOVING Parameters 95 9 6 Features Parameter...

Page 6: ...Longitude X2 ID 1035 106 9 6 26 Geofence Zone 1 Latitude Y2 ID 1036 106 9 6 27 Enable Disable ID 1101 107 9 6 28 Activation Timeout ID 1102 107 9 6 29 AutoGeofence event Priority ID 1103 108 9 6 30 AutoGeofence event generating ID 1104 108 9 6 31 Radius ID 1105 108 9 7 Accelerometer parameters 109 9 7 1 Acceleration Range Configuration ID 1290 109 9 7 2 Movement Filter Start ID 1293 109 9 7 3 Move...

Page 7: ...ion method ID 2101 115 9 9 3 Fuel type ID 102 115 9 9 4 Engine Volume ID 2104 115 9 9 5 Correction ID 2103 115 9 9 6 OBD I O Configuration 116 9 9 7 I O 1 Element SMS Event Configuration ID 100 117 10 Module installation 120 ...

Page 8: ...n please consult qualified personnel The programming must be performed using a second class PC with autonomic power supply The device is susceptible to water and humidity Any installation and or handling during a lightning storm are prohibited DB3 Plug Play has USB interface Please use cables provided with DB3 Plug Play device Rewire Security is not responsible for any harm caused by using wrong c...

Page 9: ... part or all of the contents of this document in any form without the prior written permission of Rewire Security is prohibited Other products and company names mentioned here may be trademarks or trade names of their respective owners The manufacturer reserves the right to make changes and or improvements at any time in design functionality parameters and electrical characteristics without any pr...

Page 10: ... has a standard OBD II interface which lets you monitor basic vehicle parameters DB3 Plug Play also has a USB port for device status log output and entering configurations Note Monitored basic vehicle parameters depend on vehicle mark and model 2 1 Package Contents1 The DB3 Plug Play device is supplied to the customer in a cardboard box containing all the equipment that is necessary for operation ...

Page 11: ...status Note Ignition input parameter depends on vehicle mark and model Special features Any element event triggers speed external voltage etc Highly configurable data acquisition and sending Multiple Geo fence areas Sleep mode Deep sleep mode Configurable scenarios available Real time process monitoring Authorized number list for remote access Firmware update over GPRS or USB port Configuration up...

Page 12: ... charge current average 121 mA Deep Sleep average less than 4 mA3 Operation temperature 25 C 55 C Storage temperature 40 C 70 C Storage relative humidity 5 95 no condensation GNSS Internal GNSS antenna GSM Internal GSM antenna OBD II connector Standard OBD II connector USB Mini USB socket Table 1 DB3 Plug Play specifications 2 Energy consumption has been tested at 12V voltage 3 When in Deep Sleep ...

Page 13: ......

Page 14: ...y view dimensions tolerance 1 mm 2 5 Absolute Maximum Ratings VALUE CHARACTERISTIC DESCRIPTION Min Typ Max Unit Supply Voltage Absolute Maximum Ratings 16 16 V Digital Input Ignition Voltage Absolute Maximum Ratings 32 32 V ...

Page 15: ...3 Connection Pinout 3 1 How To Insert SIM Card Into DB3 Plug Play Device Gently open DB3 Plug Play case using screwdrivers ...

Page 16: ... Remove DB3 Plug Play case Insert SIM card as shown Insert battery wire to connector Attach top housing cover ...

Page 17: ...XP with SP3 or later Windows Vista Windows 7 Windows 8 MS NET Framework V3 5 or later http www microsoft com or Installing drivers Extract and run VCPDriver_V1 3 1_Setup exe This driver is used to detect DB3 Plug Play device connected to the computer Click Next in driver installation window figures below Figure 2 Driver installation window ...

Page 18: ... button again Figure 3 Driver installation window Setup will continue installing drivers and will display a window about the successful process at the end Click Finish to complete setup Figure 4 Driver installation window You have now installed drivers for DB3 Plug Play device successfully ...

Page 19: ... Deep sleep mode Or GNSS antenna short circuited 3 4 Status LED Behaviour Meaning Blinking every second Normal mode Blinking every 2 seconds Deep sleep mode Blinking fast for a short time Modem activity Blinking fast constantly Boot mode Off Device is not working Or Device firmware being flashed 3 5 ODB II Pin Nr Pin Name Description 1 Ignition input 2 PWM BUS VPW 3 ...

Page 20: ... GND Ground pin 5 GND Ground pin 6 CAN H 7 K Line 8 9 10 PWM BUS 11 12 13 14 CAN L 15 L Line 16 Power 10 16 V DC Power range 10 16 V DC to ground Table 2 OBD II pinout description Figure 5 OBD II pinout ...

Page 21: ...ini USB connector Figure 6 Mini USB type B connector DB3 Plug Play connected to PC creates an STM Virtual COM Port which can be used as a system port to flash firmware and configure the device Figure 7 COM Ports ...

Page 22: ... device must be powered on Connect DB3 Plug Play to PC with the USB cable Launch Firmware Updater select COM port to which device is connected click connect and when IMEI and Firmware version fields are filled start the update The device needs some time to send IMEI and Firmware version so do not be afraid if IMEI will not show up immediately disconnect and after 1 2 minutes try to connect again T...

Page 23: ...d angle based method Note that if DB3 Plug Play loses connection to GNSS satellites it continues to make records however coordinate in these records remains the same last known coordinate Method s details are described in section 5 11 All data is stored in flash memory and later can be sent via GPRS GPRS and SMS settings are described in later sections DB3 Plug Play communicates with the server us...

Page 24: ...eep mode The device must be synchronized time with GNSS satellites DB3 Plug Play has to be in X on Stop Mode Configured by Mode switch parameter Ignition Configured to be detected by Power Voltage Ignition or Accelerometer is off Sleep timeout is reached DB3 Plug Play exits sleep mode when if ONE of following conditions are true DB3 Plug Play switches to X on Moving Mode Ignition Configured to be ...

Page 25: ...Acquisition Mode settings must be bigger than Active Data Link Timeout parameter that DB3 Plug Play could close GPRS link Send period Data Acquisition Mode settings minus Active Data Link Timeout must be more than 90 sec that DB3 Plug Play could close GPRS link for at least 90 sec USB cable is not connected Sleep timeout is reached DB3 Plug Play exits deep sleep mode when if ONE of following condi...

Page 26: ...s Between Records except odometer is not reset to zero after each record The odometer is only reset after the current trip ends Continuous from OBD mode works similar to Continuous from GPS however travelled distance data is taken from OBD instead of GNSS signal 5 4 Features Using available features can greatly increase DB3 Plug Play usability options 5 4 1 Scenarios Seven scenarios are available ...

Page 27: ...t from exceeding fixed speed and inspects driver if needed Over Speeding event is generated only when the vehicle speed exceeds configured Max allowed speed Excessive Idling Detection Scenario informs you if your vehicle is stationary but the engine is on for a selected period of time to help you to save fuel Jamming detection Scenario detects GSM connection jamming to inform you that your vehicle...

Page 28: ...ng is another feature which is highly customizable and can detect wherever car enters or leaves customized areas More about Geofencing can be read in 5 11 3 Geofencing settings chapter Auto Geofencing feature if enabled is activated automatically by turning off car Ignition Configured to be detected by Power Voltage Ignition or Accelerometer Next time before driving user has to disable Auto Geofen...

Page 29: ...version can be downloaded from official Microsoft web page Module configuration is performed over USB cable Configuration process starts from starting DB3 Plug Play Configurator program and then connecting to DB3 Plug Play device via Connect button located on the top left corner of the configurator If connected successfully IMEI Version fields which were empty now are filled with certain numbers d...

Page 30: ...Recommended device configuration is simple and is performed as follows Connect device to configurator Save configuration and disconnect Enter GSM provided APN APN user name password domain Target server port Plug device to your vehicle and it is ready to use ...

Page 31: ...ys go back to recommended configuration menu only by clicking Recommended Configuration button in main button area area 1 For further device configuration in Advanced mode read description below DB3 Plug Play in advanced configuration has one user editable profile which can be loaded from the device and saved The user can also reset to default settings by pressing Load Defaults button After any mo...

Page 32: ...irmware version Additional Buttons description SIM PIN allows the user to enter PIN code if inserted SIM card has activated PIN code security Note that PIN code can be entered 2 times After that SIM CARD must be removed from DB3 Plug Play and PIN code entered manually Add Keyword Change Keyword Switch Security Off buttons are used to protect configurator from unauthorized access to configuration T...

Page 33: ...L4 application More details on how to use TAVL application please refer to TAVL4 application user manual documentation 5 8 System Settings System settings have 6 configurable parameters Sleep settings where the user can turn sleep deep sleep on or off Mode Switch Settings where the user can configure 3 ways how DB3 Plug Play will change its working mode Ignition Settings where the user can configu...

Page 34: ...ion is turned on except if the battery is fully charged or 10 minute timeout has not passed since the device was turned on for faster FIX receiving If the ignition is off charger must be turned off Mode Switch by The vehicle in Stop mode Vehicle Moving mode Ignition recommended If the ignition is low Configured to be detected by Power Voltage Ignition or Accelerometer If the ignition is high Confi...

Page 35: ...Timeout is used to set a timeout of the link between DB3 Plug Play and AVL application termination If DB3 Plug Play has already sent all records it waits for new records before closing link If new records are generated in the period of this timeout and minimum count to send is reached they are sent to AVL application This option is useful when GSM operator charges for link activation Server Respon...

Page 36: ...parameters Some operators use specific authentication for GPRS session CHAP or PAP If any of these is used APN should be entered as chap APN or pap APN I e if the operator is using APN internet with CHAP authentication it should be entered as chap internet Information about APN and authentication type should be provided by your GSM operator Figure 15 GPRS configuration 5 10 2 SMS Essential fields ...

Page 37: ...eport with SMS Sent SMS is ggps SMS format If Authorized numbers list is used location SMS would be sent only to authorized number If Caller is not in the authorized User List position SMS would not be sent Figure 16 SMS configuration Note A mobile phone will not understand SMS with a binary code so sending it to a mobile phone is useless When sending a binary SMS to a phone number which is a serv...

Page 38: ...o send a configured SMS when an event is triggered This event can be triggered by scenarios trip geofencing autogeofencing I O OBD events Figure 17 SMS Events configuration When any of the above events is triggered DB3 Plug Play sends a configured SMS message to a defined phone number If SMS events are activated but there are no numbers defined in the SMS events PreDefined Numbers list figure 18 t...

Page 39: ... symbols in ASCII except for comma ATTENTION If DB3 Plug Play is in Deep Sleep mode and SMS event occurs with LOW priority which does not wake up DB3 Plug Play then the device does not send the message It is saved in device memory until it wakes up from Deep Sleep mode and GSM modem starts working normally After it wakes up all the messages that are saved in memory will be sent but keep in mind th...

Page 40: ... settings for more details Figure 21 Operator list configuration 5 11 Data Acquisition Mode Settings Data Acquisition Modes are an essential part of DB3 Plug Play device it is also highly configurable By configuration the user defines how records will be saved and sent There are three different modes Home Roaming and Unknown All these modes with configured data acquisition and send frequencies dep...

Page 41: ...quisition mode This functionality allows having different AVL records acquire and send parameters values when the object is moving or stands still The vehicle moving or stop state is defined by Mode Switch parameter There are 3 ways for DB3 Plug Play to switch between Vehicle on Stop and Vehicle Moving modes see section 5 711 DB3 Plug Play allows having 6 different modes Operational logic is shown...

Page 42: ... period If it does not have enough records depends on parameter Min Saved Records described above it tries again after the defined time interval GPRS Week Time tab most GSM billing systems charge number of bytes kilobytes transmitted per session During the session DB3 Plug Play makes the connection and transmits data to a server DB3 Plug Play tries to handle the session as much as possible it neve...

Page 43: ...nterval If so DB3 Plug Play saves the record to memory If not DB3 Plug Play checks if the distance from the last record to current record is equal or higher than Distance based acquire interval If so saves the record to memory If not and speed is higher than 10km h then DB3 Plug Play checks if angle difference between last record and the current record is equal or higher than Angle based acquire v...

Page 44: ...vious coordinate and the current position is greater than defined parameter value Entering zero disables data acquisition depending on distance Angle based data acquiring Min angle records are being acquired when angle difference between last recorded coordinate and current position is greater than the defined value Entering zero disables data acquisition depending on the angle 5 11 1 Scenarios Se...

Page 45: ...ect timeouts for stationary time and for movement time Jamming Detection User can select Jamming detection sensitivity RSSI threshold Low Normal High and Disable this functionality 5 11 2 Trip Settings If OBD data and PIDs are available odometer value will be calculated from OBD if not from GPS The trip window offers the user to configure Trip feature If Trip is enabled configuration of parameters...

Page 46: ...eld When Trip is over and next Trip begins Odometer value is reset to zero When the next trip starts the device starts to count distance continuously from zero Figure 23 Trip configuration Figure 24 Trip continuous distance counting parameter example The user can configure vehicle s real odometer value This value will be incremented by odometer functionality If DB3 Plug Play is used in another veh...

Page 47: ...n additional border around Geofence zone It is the additional area around defined zone used to prevent false event recording when the object stops on the border of the area and because of GNSS errors some records are made inside the area and some outside The event is generated only when both borders are crossed See figure 26 for details the blue track is considered to have entered the area while t...

Page 48: ...ll be generated X1 geofence zone left bottom corner X coordinate longitude Y1 geofence zone left bottom corner Y coordinate latitude X2 or R geofence zone upper right corner X coordinate longitude or radius of a circle when the Circular zone is used radius in meters Y2 geofence zone upper right corner Y coordinate latitude Figure 27 Geofence configuration 5 11 4 Autogeofencing Settings AutoGeofenc...

Page 49: ... which will be applied to the saved record Enter Event Event generation on Geofence entrance Exit Event Event generation on Geofence exit On Both Event generation on Geofence entrance Or exit Note that AutoGeofencing does not require entering coordinates instead it requires GNSS visibility If vehicle stopped and activation timeout has passed an AutoGeofence will be created around vehicle s last po...

Page 50: ...rip Distance Distance between the trip start and trip stop m 5 Total Distance Total driven distance km 6 GSM Signal GSM signal level value in scale 1 5 7 Movement 0 not moving 1 moving 8 Battery Voltage Battery voltage mV 9 Deep sleep 0 not deep sleep mode 1 deep sleep mode 10 Battery Current Battery current mA 11 Data Mode 0 home on stop 1 home on move 2 roaming on stop 3 roaming on move 4 unknow...

Page 51: ...get left zone 1 target entered zone 19 Geozone 03 Event 0 target left zone 1 target entered zone 20 Geozone 04 Event 0 target left zone 1 target entered zone 21 Geozone 05 Event 0 target left zone 1 target entered zone 22 Auto geofence Event 0 target left zone 1 target entered zone 23 Trip 1 trip start 0 trip stop 24 Greendriving type 1 harsh acceleration 2 harsh braking 3 harsh cornering 25 Green...

Page 52: ...L packet is needed when the current value of I O exceeds predefined High and Low levels I O settings allow defining I O event criteria Figure 29 I O settings Enabled or disabled field allows enabling I O element so it is added to the data packet and is sent to the server By default only main I O elements are Priority AVL packet priority can be low high or panic Regular packets are sent as Low prio...

Page 53: ...efore event generating Averaging constant allows setting I O event delay averaging If I O value is entering or leaving the predefined range it must have the same value for Averaging constant time 1 Averaging constant value equals about 100 milliseconds Param AvgConst sek 10 For example Value 3 300ms In Deep Sleep mode there is no Averaging Note I O element s Movement Averaging constant is interpre...

Page 54: ...igital Input event generation example 5 12 2 Hysteresis Figure 31 Hysteresis parameter configuration I O elements can generate events according to hysteresis algorithm If I O event operand Hysteresis is selected events will be generated as it is shown in the illustration below I O speed is taken as I O value example ...

Page 55: ...230 4 KWP 5 baud init 10 4 kbaud 5 ISO 14230 4 KWP fast init 10 4 kbaud 6 15765 4 CAN 11 bit ID 500 kbaud 7 ISO 15765 4 CAN 29 bit ID 500 kbaud 8 ISO 15765 4 CAN 11 bit ID 250 kbaud 9 ISO 15765 4 CAN 29 bit ID 250 kbaud 10 SAE J1939 CAN 29 bit ID 250 kbaud 5 13 2 Data Data is saved as I O elements OBD I O elements must be enabled using configurator All OBD elements are configured in same logic as ...

Page 56: ... 5 Engine coolant temperature 40 215 C 1B x1 6 Short term fuel trim 1 100 99 1B X1 10 Fuel pressure 0 765 kPa 2B X1 11 Intake manifold absolute pressure 0 255 kPa 1B X1 12 Engine RPM 0 16383 rpm 2B X1 13 Vehicle speed 0 255 km h 1B X1 14 Timing advance 64 63 1B X1 15 Intake air temperature 40 215 C 1B X1 16 MAF air flow rate 0 65535 g s 2B X0 01 17 Throttle position 0 100 1B X1 ...

Page 57: ... 2B X1 51 Barometric pressure 0 255 kPa 1B X1 66 Control module voltage 0 65535 mV 2B X1 67 Absolute load value 0 25700 2B X1 70 Ambient air temperature 40 215 C 1B X1 77 Time run with MIL on 0 65535 min 2B X1 78 Time since trouble codes cleared 0 65535 min 2b X1 89 Absolute fuel rail pressure 0 65535 kPa 2B X10 91 Hybrid battery pack remaining life 0 100 1B X1 92 Engine oil temperature 40 210 C 1...

Page 58: ...tion on configurator window Auto DB3 Plug Play independently decides how to calculate fuel consumption depending on PIDs availability and configured fuel type From PID no calculations are established Fuel value is taken from the vehicle Calculate from OBD data same as Auto but does not use PID 94 if it is available from OBD data Calculated by norm value not implemented yet Fuel Type vehicle fuel t...

Page 59: ...figured for individual needs Acceleration range specifies measurement range for the accelerometer The smaller the range the more precisely configuration can be set Bigger ranges are only acceptable for harsh acceleration or crash detection 6 SMS Command List All commands are case sensitive While DB3 Plug Play operates in Deep Sleep mode and the user tries to send SMS message it cannot arrive to DB...

Page 60: ...and time Yes getinfo Device runtime system information Yes getver Device Modem Code version information Yes allver Device HW version information cpureset Reset CPU No resetprof Reset all FLASH1 profile configuration to the default profile Yes deleterecords Delete all records saved on FLASH Yes getio ReaMS Event Predefined digital input 1 Yes readio Readout input value according entered ID ID value...

Page 61: ...ration to default Yes battery Battery information Yes cleardtc Clears all vehicle stored trouble codes and turns the MIL off obdinfo Returns OBD info Protocol VIN AdaptiveTiming value requested PID counter OBD application state available vehicle PIDs fuel calc method mil status number of DTCs Yes faultcodes Fault codes reading from OBD Yes 6 1 1 Getstatus Response details Description Data Link Ind...

Page 62: ...Tower Location Area Code Cell ID GSM Tower Cell ID Code Example Data Link 0 GPRS 1 Phone 0 SIM 0 OP 24602 Signal 5 NewSMS 0 Roaming 0 SMSFull 0 LAC 1 Cell ID 864 6 1 2 Getweektime Response details Description Clock Sync Indicates system clock synchronization status 0 System is not synchronized 1 System synchronized DOW Day Of Week indicates current day of the week starting from 0 Monday 1 Tuesday ...

Page 63: ...te Time Returns last performed configuration date and time Example Last Configuration was performed on 2010 4 15 5 45 19 6 1 5 Ggps Response details Description D Date T Time S Actual Speed C Latitude Last good Latitude Longitude Last good Longitude Url Google Maps Link Example D 2013 7 4 T 0 0 0 S 0 C 0 0 Url http maps google com q 0 0 om 1speed 0 6 1 6 Getgps ...

Page 64: ...nd speed km h Dir Ground direction degrees Date Current date Time Current GMT time Example GNSS 1 Sat 7 Lat 54 71473 Long 25 30304 Alt 147 Speed 0 Dir 77 Date 2007 8 24 Time 13 4 36 6 1 7 Getinfo Response details Description INI Device Initialization Time RTC RTC Time RST Restart Counter ERR Error Counter SR Number of Sent Records BR Number of broken records CF Profile CRC Fail counter FG Failed G...

Page 65: ... Pin Reset MD Data Mode state 0 Home and Stop 1 Home and Moving 2 Roaming and Stop 3 Roaming and Moving 4 Unknown and Stop 5 Unknown and Moving Example INI 2007 8 24 10 15 RTC 2007 8 24 12 43 RST 2 ERR 11 SR 182 BR 0 CF 0 FG 0 FL 0 UT 0 SMS 2 NOGNSS 0 0 GNSS 3 SAT 7 RS 5 MD 0 6 1 8 Getver Response details Description Code Ver Firmware version Rev Firmware revision Device IMEI IMEI Device ID Device...

Page 66: ... 1 9 Allver Response details Description 1 Device name 2 Firmware version 3 Firmware revision 4 IMEI 5 Firmware compile date 6 Bootloader version 7 Device ID 8 Flash Manufacturer ID 9 Flash Capacity 10 Version of modem application 11 HW revision voltage 12 GNSS module description Example DB3 00 06 02 0 356307044051570 Jul 6 2015 07 01 0E EF 14 1 07 00 1373 G33_030106 6 1 10 Getio ...

Page 67: ...rs and IDs can be found in chapter number 8 Parameter List Example getparam 1245 command will request server IP address 6 1 13 Setparam Sets new value for the parameter ID consists of 3 or 4 digits Detailed list of parameters and IDs can be found in chapter number 8 Parameter List Example setparam 1245 127 0 0 1 will change configured IP address 6 1 14 Flush Initiates all data sending by GPRS to s...

Page 68: ...iption FLUSH SMS Accepted FLUSH SMS Accepted records found on FLASH Number of records found on FLASH Minimum Records to Send Number of minimum saved records to send GPRS Enabled State of the GPRS connection 0 disabled 1 enabled Time Sync Indicates time synchronization on the device 0 not synchronized 1 synchronized Example FLUSH SMS Accepted 11 records found on FLASH Minimum Records to Send 1 GPRS...

Page 69: ...d 6 1 18 Battery Returns DB3 Plug Play battery information Example BatState 1 FSMState ACTIVE ChargerIC CHARGING ExtV 14020 BatV 3800 BatI 50 PCBTemp 35 2 6 1 19 Cleardtc Clears all vehicle stored trouble codes and turns the MIL off Example DTC cleared OK or DTC cleared ERROR 6 1 20 Obdinfo Response details Description LIST of OBD info Protocol VIN AdaptiveTiming value requested PID counter OBD ap...

Page 70: ...eriodically to a server a message could be sent from the server and DB3 Plug Play will reply to it DB3 Plug Play has to be connected to the server in order to receive commands Command Description GET DATAORDER Get info about records sorting parameter SET DATAORDERX Y Set records sorting parameter X profile Y value 0 1 GET RECTO Get info about records refresh timeout parameter SET RECTO X Set recor...

Page 71: ...tion of a certain profile X profile no Y IP or domain Z port number GET AUPX Get APN user login and password from the configuration of a certain profile X profile SET AUPX Y Z W Set APN user login and password to the configuration of a certain profile X profile Y APN Z user login W password GET REPRTX Get MinPeriod from the configuration of a certain profile X profile SET REPRTX Y Set MinPeriod to...

Page 72: ...file Y MinRecords value GET IBTNX Y Get iButton value from the configuration of a certain profile X profile Y number on the list SET IBTNX Y Z Set iButton value to the configuration of a certain profile X profile Y number on the list Z iButton value GET EXTERR Get extended errors value SET EXTERR X Set extended errors value X 0 1 GET VIN Returns vehicle VIN number GET FAULTCODES Reads fault codes ...

Page 73: ...ile into RAM Engine Profile number of profile to load cpureset Reset CPU resetallprof Reset all FLASH profiles to default profile getver Device Modem Code version information getinfo Device runtime system information deleterecords Delete all records saved on FLASH getio Readout digital inputs and outputs analog inputs readio Readout input value according entered ID ID value getparam Readout parame...

Page 74: ...er to send these commands they have to be converted to a special format How to convert to this format and for additional information on how to send GPRS commands please contact your local sales representative 8 Debug mode DB3 Plug Play is able to transmit its current state when connected to PC using the USB cable It is used to detect errors and provide information to possible solutions when operat...

Page 75: ...get NMEA data simply enter the following command into the command field log_nmea 1 0a Figure 36 Terminal window for logging 9 Parameter List 9 1 Parameters Value Types S8 Signed Char S8 n String of n Char U8 Unsigned Char U16 Unsigned Short S32 Signed Integer U32 Unsigned Integer U64 Unsigned Long Integer 9 2 System Parameters 9 2 1 Sleep Mode ID 1000 ...

Page 76: ...D 1001 Sleep timeout is time after which DB3 Plug Play goes to sleep or deep sleep if other requirements are met It is measured in minutes Minimum value Maximum value Recommended value Goes with depends on parameters Value type 1 3000 U8 9 2 3 Mode Switch Source ID 1002 The device can operate and change its working mode according to motion detection source ignition value 0 movement value 1 GNSS va...

Page 77: ...bled Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 1 U8 9 2 6 Saving Sending without time synchronization ID 1005 When this feature is enabled value 1 then records can be saved and sent to the server without time synchronization Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 1 1 U8 9 2 7 Power Voltage Low Leve...

Page 78: ...rs Value type 0 30000 Ignition Source ID 1003 Power Voltage Level Low Level 1006 U16 9 2 9 LED Indication ID 1008 Parameter enables disables led indication 0 disabled 1 enabled default Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 1 U8 9 2 10 Battery charge mode ID 1009 Parameter sets battery charge mode 0 on need default 1 after ignition on Minimum val...

Page 79: ... server after successful data transfer while waiting for a new record Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 259200 U32 9 3 3 Server Response Timeout ID 1012 Defines time period in seconds for server response to sent records Minimum value Maximum value Recommended value Goes with depends on parameters Value type 1 300 U8 ATTENTION Some GSM operat...

Page 80: ...4 hours or more If data sending is more frequent then the operator will not disconnect the device from the server 9 4 GSM parameters 9 4 1 GPRS Content Activation ID 1240 Parameter allows or does not allow GPRS usage If GPRS is not allowed value is 0 if GPRS is allowed value is 1 Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 1 APN Name ID 1242 APN usern...

Page 81: ...1240 APN Name ID 1242 S8 30 APN Password ID 1244 9 4 4 APN Password ID 1244 The parameter defines APN password In case the operator does not use a password for login the value should be empty Minimum value Maximum value Recommended value Goes with depends on parameters Value type Empty 30 char string GPRS content activation ID 1240 APN Name ID 1242 APN username ID 1243 S8 30 9 4 5 Main Server Doma...

Page 82: ...r backup server Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 50 char string GPRS content activation ID 1240 Main Server Domain ID 1245 S8 16 9 4 7 Target Main Server Port ID 1246 Parameter defines AVL data destination main server port number Example 12050 Minimum value Maximum value Recommended value Goes with depends on parameters Value type Empty 655...

Page 83: ...alue type Empty 65535 GPRS content activation ID 1240 Backup Server Domain ID 1241 Target Main Server Port 1246 GPRS content activation ID 1240 Main Server Domain ID 1245 U16 9 4 9 Protocol ID 1247 Parameter defines GPRS data transport protocol for main server Module can use TCP or UDP transport protocol to send data to server For TCP protocol value is 0 for UDP protocol value is 1 Minimum value M...

Page 84: ...alue type 0 1 GPRS content activation ID 1240 U8 9 4 11 SMS Login ID 1252 User login is used to ensure module security Used in every SMS that is sent to the device Example ba321 Minimum value Maximum value Recommended value Goes with depends on parameters Value type Empty 5 char SMS Password ID 1253 S8 5 9 4 12 SMS Password ID 1253 User password is used to ensure module security Used in every SMS ...

Page 85: ... in Location by call function The number must be entered without or 00 Example 37060012346 Minimum value Maximum value Recommended value Goes with depends on parameters Value type 1 digit 16 digits S8 17 If SMS data sending is enabled ID 1250 first value in a list is server GSM number The SMS with panic priority will be sent 9 4 15 SMS Event PreDefined Numbers ID 150 159 In this field are written ...

Page 86: ... the roaming network GSM operator codes are comma separated example 24601 24602 24705 24503 Minimum value Maximum value Recommended value Goes with depends on parameters Value type Empty 7 digits U32 9 5 Data Acquisition Modes Parameters 9 5 1 Home Network GSM operator code Vehicle on STOP Parameters 9 5 1 1 Min Period ID 1540 This parameter indicates time interval in seconds in order to acquire n...

Page 87: ... Value type 1 255 1 GPRS Week Time ID 1545 U8 9 5 1 3 Send Period ID 1544 This parameter indicates frequency time interval in seconds of sending data to the server Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 2592000 Min Saved Records ID 1543 GPRS Week Time ID 1545 U32 9 5 1 4 GPRS Week Time ID 1545 This parameter manages when it is allowed to open GPR...

Page 88: ...4 bits Every nth bit beginning from the first bit LSB and ending 18 bytes 8th bit MSB indicates every 10th minute of the day day has 1440 minutes Sample GPRS will be allowed on Monday to Friday at 8 00 and 16 00 GMT The following value should be configured 00011111 00000000 00000000 00000000 000000000 00000000 00000000 00000001 00000000 00000000 00000000 00000000 00000000 000000001 00000000 000000...

Page 89: ...commended value Goes with depends on parameters Value type 0 65535 Min Period ID 1550 Min Angle ID 1552 GPRS Week Time ID 1555 U32 9 5 2 3 Min Angle ID 1552 This parameter indicates angle in degrees in order to acquire new record If angle difference between last recorded coordinate and current position is greater than the defined value a new record is stored This parameter is operational when spee...

Page 90: ...1554 Minimum value Maximum value Recommended value Goes with depends on parameters Value type 1 255 1 Min Period ID 1550 Min Distance ID 1551 Min Angle ID 1552 GPRS Week Time ID 1555 U8 9 5 2 5 Send Period ID 1554 This parameter indicates frequency time interval in seconds of sending data to the server Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 25920...

Page 91: ...592000 U32 9 5 3 2 Min Saved Records ID 1563 This parameter defines the minimum number of records in one data packet that can be sent to the server It has higher priority than Data Send Period ID 1564 Minimum value Maximum value Recommended value Goes with depends on parameters Value type 1 255 1 GPRS Week Time ID 1565 U8 9 5 3 3 Send Period ID 1564 This parameter indicates frequency time interval...

Page 92: ...e saved Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 2592000 Min Distance ID 1571 Min Angle ID 1572 GPRS Week Time ID 1575 U32 9 5 4 2 Min Distance ID 1571 This parameter indicates distance in meters in order to acquire new record The record is stored when the distance between previous records is greater than parameter s value If the value is 0 it mean...

Page 93: ... If the value is 0 it means no records by min angle will be saved Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 180 Min Period ID 1570 Min Angle ID 1572 GPRS Week Time ID 1575 U16 9 5 4 4 Min Saved Records ID 1573 This parameter defines the minimum number of records in one data packet that can be sent to the server It has higher priority than Data Send ...

Page 94: ...ed Records ID 1573 GPRS Week Time ID 1575 U32 9 5 4 6 GPRS Week Time ID 1575 Read GPRS Week Time ID 1545 9 5 5 Unknown Network GSM Operator Code Vehicle On STOP Parameters 9 5 5 1 Min Period ID 1580 This parameter indicates time interval in seconds in order to acquire new record If the value is 0 it means no records by min period will be saved Minimum value Maximum value Recommended value Goes wit...

Page 95: ... This parameter indicates frequency time interval in seconds of sending data to the server Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 2592000 Min Saved Records ID 1583 GPRS Week Time ID 1585 U32 9 5 5 4 GPRS Week Time ID 1585 Read GPRS Week Time ID 1545 9 5 6 Unknown Network GSM Operator Code Vehicle MOVING Parameters 9 5 6 1 Min Period ID 1590 This ...

Page 96: ... will be saved Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 65535 Min Period ID 1570 Min Angle ID 1572 GPRS Week Time ID 1575 U32 9 5 6 3 Min Angle ID 1592 This parameter indicates angle in degrees in order to acquire new record If angle difference between last recorded coordinate and current position is greater than the defined value a new record is s...

Page 97: ...e Recommended value Goes with depends on parameters Value type 1 255 1 Min Period ID 1590 Min Distance ID 1591 Min Angle ID 1592 GPRS Week Time ID 1595 U8 9 5 6 5 Send Period ID 1594 This parameter indicates frequency time interval in seconds of sending data to the server In order to send data to server GPRS parameters must be enabled Minimum value Maximum value Recommended value Goes with depends...

Page 98: ...s with depends on parameters Value type 0 3 U8 9 6 2 Max Acceleration Force ID 1602 It is max allowed acceleration force which can be reached while accelerating without triggering harsh acceleration event Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 25 0 85 0 25 Scenarios Enable ID 1600 Float 9 6 3 Max Braking Force ID 1603 It is max allowed braking fo...

Page 99: ...ed Speed ID 1605 It is max allowed speed which can be reached If this value exceeded Over speeding event will occur Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 260 Scenarios Enable ID 1600 U16 9 6 6 Excessive Idling Detection ID 1607 If ignition is ON and no movement the event will be generated when TMO reached This functionality is 1 enabled 0 disabl...

Page 100: ... ID 1607 Time to movement ID 1609 U8 9 6 8 Time to Movement ID 1609 If ignition is ON and no movement the event will be generated when TMO reached This functionality is 1 enabled 0 disabled default Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 255 Time to stationary ID 1608 Scenario Enable ID 1607 U8 9 6 9 Jamming Detection ID 1606 Jamming detection sen...

Page 101: ... depends on parameters Value type 0 2 U8 9 6 11 Unplug Detection ID 1611 Unplug detection can be set to 0 disabled default 1 simple 2 advanced Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 2 U8 9 6 12 Crash Detection ID 1612 Crash detection can be set to generate low or high priority event on crash 0 disabled default 1 low priority event 2 high priority...

Page 102: ...represents speed which is detected as minimum speed to indicate TRIP START and generate event Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 255 U8 9 6 15 Ignition Off Timeout ID 1282 This parameter represents timeout to wait if the ignition is off in order to detect TRIP STOP and generate an event Minimum value Maximum value Recommended value Goes with ...

Page 103: ...distance continuously from Trip start to Trip stop when Distance Mode parameter is set to continuous 9 6 18 Odometer Value ID 1284 Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 999999 Trip ID 1280 U16 Geofencing In this chapter it is explained how to get all parameters for the first Geofence zone all ID numbers are for the 1st zone And at the end of the...

Page 104: ...on parameters Value type 0 1 All Geofencing parameters U8 9 6 21 Geofence Zone 1 Priority ID 1031 Parameter defines Geofence priority 0 low 1 high 2 panic Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 2 All Geofencing parameters U8 9 6 22 Geofence Zone 1 Generate Event ID 1032 Generate event on a No event value 0 b On entering zone value 1 c On exiting ...

Page 105: ... then ID 1033 is centre of that circle X coordinate Sample value 25 30528 Minimum value Maximum value Recommended value Goes with depends on parameters Value type 180 180 All Geofencing parameters Float 9 6 24 Geofence Zone 1 Latitude Y1 ID 1034 The parameter has two meanings dependent on zone shape If the shape is a rectangle then ID 1034 is left down corner Y coordinate If the shape is a circle ...

Page 106: ...h depends on parameters Value type 180 180 All Geofencing parameters Float For circle Minimum value Maximum value Recommend ed value Goes with depends on parameters Value type 0 1000000 1000 All Geofencing parameters Float 9 6 26 Geofence Zone 1 Latitude Y2 ID 1036 If the shape is rectangular then ID 1036 is right upper corner Y coordinate If shape circle ID 1036 is not used Minimum value Maximum ...

Page 107: ...ue 1 disable value 0 Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 1 1 U8 9 6 28 Activation Timeout ID 1102 The parameter represents AutoGeofencing activation timeout in seconds Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 65535 60 Enable Disable ID 1101 U16 ...

Page 108: ...ID 1104 Generate event 0 no event 1 on entering zone 2 on exiting zone 3 on both Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 3 2 Enable Disable ID 1101 AutoGeofence event Priority ID 1103 U8 9 6 31 Radius ID 1105 The parameter represents the radius of a circle with centre device coordinates after activating AutoGeofence feature Minimum value Maximum v...

Page 109: ... Start ID 1293 The parameter represents how long it takes to generate movement event in seconds Minimum value Maximum value Recommended value Goes with depends on parameters Value type 1 60 0 Ignition Source ID 1003 U32 9 7 3 Movement Filer Stop ID 1294 The parameter represents how long it takes to change movement I O element state from 1 to 0 in seconds Minimum value Maximum value Recommended val...

Page 110: ... Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 1 I O 1 priority ID 1301 I O 1 High level ID 1302 I O 1 Low level ID 1303 I O 1 logic operand ID 1304 I O 1 averaging length ID 1305 S8 9 8 2 I O 1 Priority ID 1301 The parameter defines I O property type of priority 0 is low 1 high 2 panic Minimum value Maximum value Recommended value Goes with depends on ...

Page 111: ...ameter defines the high value of triggered I O property This parameter is used to set thresholds for I O properties to generate events Minimum value Maximum value Recommended value Goes with depends on parameters Value type 2147483648 2147483647 1 I O 1 property parameter ID 1300 I O 1 priority ID 1301 I O 1 Low level ID 1303 I O 1 logic operand ID 1304 S32 I O 1 averaging length ID 1305 ...

Page 112: ...I O 1 property parameter ID 1300 I O 1 priority ID 1301 I O 1 High level ID 1302 I O 1 logic operand ID 1304 I O 1 averaging length ID 1305 S32 9 8 5 I O 1 Logic Operand ID 1304 Parameter defines when event is sent 0 on range exit 1 on range entrance 2 both 3 monitoring 4 hysteresis Minimal value Maximum value Recommended value Goes with depends on parameters Value type 0 4 3 I O 1 property parame...

Page 113: ...s with depends on parameters Value type 0 2592000 1 I O 1 property parameter ID 1300 I O 1 priority ID 1301 I O 1 High level ID 1302 I O 1 Low level ID 1303 I O 1 logic operand ID 1304 S32 Other I O property elements can be configured in same logic All I O element parameters are listed in the next table I O Element Number I O element parameters I O 0 Ignition 1300 1305 I O 1 GPS PDOP 1310 1315 I O...

Page 114: ...9 GSM Signal 1390 1395 I O 10 Deep Sleep 1400 1405 I O 11 GSM Cell ID 1410 1415 I O 12 GSM Area Code 1420 1425 I O 13 Battery Voltage 1430 1435 I O 14 Battery Current 1440 1445 I O 15 Total distance 1450 1455 9 9 OBD parameters 9 9 1 OBD Interface ID 2100 Enable value 1 disable value 0 Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 1 U8 ...

Page 115: ...e ID 102 0 Gasoline default 1 Diesel 2 LPG Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 2 OBD Fuel calculation method ID 2101 U8 9 9 4 Engine Volume ID 2104 Default value is 20 Value is multiplied by 10 Minimum Maximum Recommended Goes with depends on Value value value value parameters type 0 100 OBD Fuel calculation method ID 2101 U8 9 9 5 Correction ...

Page 116: ...9 6 OBD I O Configuration OBD I O configuration is the same as general I O See I O parameters There are 20 slots which can be dedicated for certain OBD parameters recognized by PID Only 20 slots are available because not many vehicles support more than 20 OBD parameters Slot number I O element parameters 1 2150 2155 2 2160 2165 3 2170 2175 4 2180 2185 5 2190 2195 6 2200 2205 7 2210 2215 8 2220 222...

Page 117: ...eters can be configured similar to I O parameters 2251 Priority 2252 High level 2253 Low level 2254 Event type 9 9 7 I O 1 Element SMS Event Configuration ID 100 Command sets SMS warning on I O 1 element SMS Format setparam X Y W Z X ID Y Enable Disable 0 1 W Telephone number INDEX See 9 4 15 SMS Event Predefined Numbers paragraph ID 150 INDEX 1 ID151 INDEX 2 Z SMS Text Example setparam 100 1 5 Di...

Page 118: ...efines SMS event text for configured OBD IO slot Element name default SMS Event Text ID Digital Input 1 100 PDOP 101 HDOP 102 Power voltage 103 Movement 104 Trip Distance 105 Actual operator Code 106 GPS speed 107 Operating Mode 108 GSM Signal 109 Deep Sleep 110 Cell ID 111 Area Code 112 Battery Voltage 113 Battery Current 114 Total Distance 115 OBD IO1 120 ...

Page 119: ...OBD IO6 125 OBD IO7 126 OBD IO8 127 OBD IO9 128 OBD IO10 129 OBD IO11 130 OBD IO12 131 OBD IO13 132 OBD IO14 133 OBD IO15 134 OBD IO16 135 OBD IO17 136 OBD IO18 137 OBD IO19 138 OBD IO20 139 Geo Zone 1 140 Geo Zone 2 141 Geo Zone 3 142 Geo Zone 4 143 ...

Page 120: ...161 Alarm 162 10 Module installation Installing DB3 Plug Play module 1 Locate OBD II connector in your car see car owner s manual for the location of the connector 2 Plug in DB3 Plug Play device in OBD II connector or use an optional extension cable Figure 37 3 If status and navigate LED lights turn on the device is ready to use ...

Page 121: ...ile module has no power 2 Please make sure that the module is firmly embedded in the OBD II connector or optional extension cable if there is not enough space for the device near the OBD II connector an extension cable may be necessary which can be ordered as an accessory not included in the package Figure 38 Correct placement of DB3 Plug Play ...

Page 122: ...t The device must not interfere with the driver Thank you for purchasing DB3 Plug Play GPS Tracker Please read this manual carefully before using this product Please note that product specifications and information in this user guide are subject to changes without prior notice Any changes will be integrated into the latest release The manufacturer assumes no responsibility for any errors or omissi...

Reviews: