7. PowerTrac
TM
Communication Faults
The following screen will appear when the battery is connected and the charger detects
the presence of a PowerTrac
TM
, but is unable to establish a link. This may be due to a
poor or reversed connection of the auxiliary wires.
If the connection to the PowerTrac
TM
is lost while a charge cycle is underway, a screen
similar to the following will be displayed:
Examining the Charge History will reveal a screen similar to this:
Possible Causes
Worn or broken auxiliary wires or auxiliary contacts
Failure of the PowerTrac
TM
Troubleshooting
a. Inspect connections on both charger and battery sides of the battery connector.
Verify auxiliary Wire #1 is connected on the positive (red) side of the battery
connector.
b. If the fault persists, contact the Dealer or Power Designers Sibex.