MAN-000037-00 REV C
36
d. Press
ENTER
key to save selection and return to the main menu. The LCD display
now indicates the Equalization charge is activated with an “E” in the upper right corner
of the display, and one of the following displays will be observed, depending on the
setup of the Charger.
2. Desulfation Cycle
One of the unique features of this charger is the ability to run a safe, tailored recovery
cycle for sulfated batteries. This can easily be done through the
DESULFATION
CYCLE
screen.
The operator enters the battery nominal voltage, Ah capacity, and the cycle duration.
The charger will output a constant current of 5% of the Ah capacity (.05*C) for the
defined duration (in the time range of 6:00 hours to 18:00 hours). Any battery capacity
above 1200 Ah will have the desulfation current limited to 60A.
a. Connect the battery to be recovered. If the charger is set to auto-start the charge
cycle, press the stop button until you are back on the “Push Start” screen
NOTE: Do not attempt to recover a battery with a capacity of less than 250
amp-hours.