Manual rEvo III
5
Chapter 1: Technical Specifications
1.1 Limitations of use:
→
This unit is intended to be used by trained people only.
→
The use of the unit is only allowed when an independent alternative gas
source is carried at all time by the diver, that can be used at any time during
the dive, and that has enough capacity to safely end the dive in case of
malfunctioning of the unit.
→
Only oxygen compatible grease like
Tribolube 71
should be used anywhere
in the unit.
→
Max certification depth: 40m with diluent air.
→
Max certification depth with trimix or heliox, and PPN2 <= 4.0 bars: 80m
(mCCR) / 100m (hCCR)
→
Temperature conditions during use: water temperature minimum 4° Celsius,
maximum 34° Celsius.
→
Scrubber endurance: at 40m depth, 4° Celsius, CO2 production of 1.6l/min
STPD, 40 RMV (2liter tidal volume), using 2.7kg
Sofnolime 797
: time until
the PPCO2 of the inhaled gas reaches 5mbar: >160 minutes. Time until
the PPCO2 of the inhaled gas reaches 10mbar: >170 minutes.
→
Scrubber endurance: at constant depth of 100m, 4° Celsius, CO2
production of 1.6l/min STPD, 40 RMV (2liter tidal volume), using 2.7kg
Sofnolime 797, using any trimix or heliox (PPN2 <= 4.0 bars): time until the
PPCO2 of the inhaled gas reaches 5mbar: >75 minutes. Time until the
PPCO2 of the inhaled gas reaches 10mbar: >85 minutes.
→
Max work rate conditions: 75 RMV at 40m depth, CO2 production of 3l/min
during 5 minutes.
→
PPO2 limits during correct use: minimum 0.5 bar, max 1.55 bar.
→
Work of breathing: at 40m depth, 4° Celsius, 75 RMV (3liter tidal volume),
using 2.7kg
Sofnolime 797
: <2.05 J/liter in horizontal position and <2.20 in
vertical position.
→
Work of breathing: at 100m depth, 4° Celsius, 75 RMV (3liter tidal volume),
using 2.7kg Sofnolime 797, using any trimix or heliox (PPN2 <= 4.0 bars)
<2.45 J/liter in horizontal position and <2.75 in vertical position.
→
Scrubber content: 2 canisters each containing 1.35kg
Sofnolime 797
.
→
Approved scrubber material:
Sofnolime 797
.
→
Tank content: oxygen and diluent tank: 2 or 3 litre .
1.2 Dimensions and features:
→
Weight of the rEvo ready to dive (full 3 litre steel cylinders, packed canister,
stainless steel housing, BCD, backplate = 31 kg (including 2.7 kg
absorbent). (micro FT with 2l cylinders: 24 kg)
→
Empty weight (without absorbent and cylinders) = 17.5kg.
→
Size: with steel 3-litre cylinders: 64 x 40 x 18 (cm).
→
Constant oxygen flow by means of an orifice, manual oxygen and diluent
addition, automatic diluent valve.
→
Two completely independent programmable PPO2 monitors with LED- indication
on two HUDs (rEvodream).
→
Securely attached mouthpiece.
→
Ergonomically integrated backplate to create a minimal static WOB (work of
breathing).