5
Reverso Pumps, Inc.
Control Panel with Digital Timer: Overview, Alarms, Reset
• Breaker for the system
• Breaker for the pump
• Siemens smart relay
• Timer push buttons: Automatic and Manual
• Stop/reset push button
• Status LED indicator lights:
• Green: The unit is energized.
• Red: Visible alarm, service system when triggered.
• Blue: Pump is active, either manual or automatic mode. To verify that the pump is operating, check the
vacuum gauge in a side of the filter, the gauge will be reading less than zero.
• Ethernet port
• Audio alarm
• High vacuum: The vacuum switch on the system is set to -16 inHg. Once the system reaches this condition
it is time to replace or backflush the element on the Separ Filter.
• High water level: When the water level reaches the maximum capacity on the filter bowl, the alarm will
trigger. Proceed to drain the bowl.
If any alarm is triggered, proceed to de-energize the pump while servicing. Make sure to follow instructions listed
in the manual.
• The buzzer will sound, and indicator light and the screen of the smart relay will be red and display the fault that is
causing the alarm. Press black button to stop the buzzer alarm (audible alarm) indicator light will shut off but the
smart relay remain on until the problem is solve.
• Use pump breaker to disconnect power from pump. Once the service is completed and the alarm issues are
resolved continue to next step.
• Press and hold black button for 3 second to reset the alarm.
Overview
Alarms
Reset (Black Button)
Ethernet connector (for
Modbus) (RJ45)
Female M12
Connector for dry
contact (remote alarm)
and motor running