background image

6

Reverso Pumps, Inc.

1.  Make sure that the system is in Manual mode.

2.  Press down arrow 2 times.

3.  Press ESC.

4.  Select Setup, press OK. 

5.  Select Clock, press OK. 

6.  Select Set clock, press OK. Use up/down arrows to select the number and right/left to move across the 

option. When done, press OK once.

7.  Press ESC 3 times to go back to the main screen for manual mode.

Digital Control

Set Date and Time

1.  Select this mode to run the system for a single preset time. Press the yellow button once to put system into 

manual mode. The smart relay will be flashing amber. 

2.  Press and hold the yellow button for 3 seconds to start the pump for manual mode. Once solid, release the 

button and the smart relay will turn solid amber while the indicator light will turn blue. This indicates that the 

pump is running. 

3.  Pump will automatically shut off after the preset run time is over. User will need to put system back into 

automatic mode if desired.

4.  If manual mode must be stopped while the system is running, press the red button Stop/Reset.

Manual Mode Operation

1.  Press yellow button to go to manual mode. Amber color will be flashing.

2.  Press down arrow to see the manual time set.

3.  Press and hold ESC. Use arrow to change unit of time in minutes or hours. Press OK and change the 

desired time to run the system. When done, press ESC.

4.  Press up arrow to go back to the principal screen.

5.  Keep press yellow button to start the pump running the system with the set time. Pump will 

automatically shut off after the preset run time is over.

6.  If the time must be reduced or increased while the system is running, repeat the steps to change the 

time for manual mode.

Set Manual Timer

Automatic Mode Operation

Modbus

Set Automatic Timer - Press green button to enter Automatic Mode

The system will start/stop automatically on the programmed days of the week and times. To set up the frequency 

take into consideration the size of the tank and the environmental conditions. When the Automatic Timer is 

selected, the pump will only begin running if within programmed date/time to run.

For an initial cleaning, we recommend the tank to be cycled 3 times. Once in Automatic mode, the cleaning can 

be performed once a week.

For information about modbus, contact Reverso Pumps, Inc.

Recommended Run Cycle = 

(Manual Mode)

Volume of the tank x 3

Flow Rate of the System

1.  Press up/down arrow to view the days of the week.

2.  Press ESC and hold for 3 seconds to set the dates and times for the selected day.

3.  Use up/down arrow to go to ON time and OFF time. Press OK. 

4.  Change the hour using the left/right arrows to move the position on time, and use 

up/down arrows to change the number.

5.  Press ESC twice to return to days of the week screen.

6.  Repeat for every day that is schedule to run the system.

7.  Press and hold green button for 3 seconds to start running the program.

Summary of Contents for FPS-150

Page 1: ...reen or Mechanical timer Featuring Separ Filter fuel water separator Shutdown and visual audio alarms Fuel Polishing System Contact Us Reverso Pumps Inc 4001 SW 47th Ave Suite 201 Davie FL 33314 Ph 954 522 0885 contact reversopumps com www reversopumps com ...

Page 2: ...g 9 Touchscreen Control System Overview 10 Touchscreen Control Maintenance 11 Mechanical Control 12 Filter Maintenance 13 FPS 80 Technical Specifications 14 FPS 80 Dimensions 15 FPS 150 Technical Specifications 16 FPS 150 Dimensions 17 FPS 210 Technical Specifications 18 FPS 210 Dimensions 19 Troubleshooting 20 The information herein is the property of Reverso Pumps Inc Without written permission ...

Page 3: ...plate Vacuum gauge Filtration Separ Filter Inlet Base Drain valve Push in and turn counter clockwise to open Control panel with digital touchscreen or mechanical control Power in Hinged cover covers pump Outlet 8 10 9 7 3 6 5 4 1 2 1 5 3 7 8 9 10 2 6 4 ...

Page 4: ...commended inner diameter refer to Technical Specifications Smaller plumbing will place excessive load on the motor and shorten its life A full port ball valve should be installed on the inlet and outlet ports of the system not included The pickup line s suction should originate from the lowest point of the tank and should be connected directly to the inlet For optimal performance ensure that this ...

Page 5: ...r High water level When the water level reaches the maximum capacity on the filter bowl the alarm will trigger Proceed to drain the bowl If any alarm is triggered proceed to de energize the pump while servicing Make sure to follow instructions listed in the manual The buzzer will sound and indicator light and the screen of the smart relay will be red and display the fault that is causing the alarm...

Page 6: ...C 4 Press up arrow to go back to the principal screen 5 Keep press yellow button to start the pump running the system with the set time Pump will automatically shut off after the preset run time is over 6 If the time must be reduced or increased while the system is running repeat the steps to change the time for manual mode Set Manual Timer Automatic Mode Operation Modbus Set Automatic Timer Press...

Page 7: ...ouchscreen Control Program Setup Select between manual and automatic operation Manual Main Menu Program Setup Automatic Ethernet connector for Modbus RJ45 Female M12 Connector for dry contact remote alarm and motor running ...

Page 8: ...Vacuum Spill Sensor Note Every 3rd high vacuum alarm it will alert for filter element replacement The number beside hi vacuum indicates how many backflushing have been executed since the last element replacement Marine Fuel Polishing Systems FPS models do not include pressure sensor and spill sensor ...

Page 9: ...rso Pumps Inc Touchscreen Control System Time Setup and System Log Set the current date and time Main Menu System Time Setup System Log Alarm Status I Sensor was OFF and turn ON IO Sensor was ON and turn OFF ...

Page 10: ...10 Reverso Pumps Inc Touchscreen Control System Overview Main Menu System Overview Note Marine Fuel Polishing Systems FPS models do not include pressure sensor and spill sensor ...

Page 11: ...11 Reverso Pumps Inc Touchscreen Control Maintenance Backflushing Filter Element Replacement Main Menu Maintenance Troubleshooting ...

Page 12: ...arm will trigger Proceed to drain the bowl If any alarm triggered proceed to de energize the pump while servicing Make sure to follow instructions listed in the manual When done press reset button Alarms 1 Ensure the fuel supply valve is open and the system is primed 2 Ensure power to the system and the green power light is illuminated 3 Turn timer knob clockwise to desired number of hours for ope...

Page 13: ...late removal only and will not remove sludge once embedded in the filter media Filter Element Replacement Prior to service ensure the system is off See Technical Specifications for torque recommendations See Technical Specifications for torque recommendations May be done up to 5 times until element replacement is required ...

Page 14: ...with foot valve above liquid level Control Digital Touchscreen or Mechanical Inlet Outlet 1 2 Male JIC Recommended Hose Minimum 1 2 inner diamter ID using quality approved fuel line materials Filter Torque Values Bowl Screws 8 Nm 70 8 in lbs Lid 8 Nm 70 8 in lbs Bleed Screw 4 Nm 35 4 in lbs Spare Parts Part Description 57 0051050 Separ 00510 50 10 micron element 57 0053050 Separ 00530 50 30 micron...

Page 15: ...TS Q A MFG APPR ENG APPR CHECKED DRAWN DIMENSIONS ARE IN INCHES TOLERANCES FRACTIONAL 1 64 ANGULAR MACH BEND 0 2 TWO PLACE DECIMAL 01 THREE PLACE DECIMAL 005 PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF REVERSO PUMPS ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF REVERSO PUMPS IS PROHIBITED Part 18 2001 02 All Dimensions f...

Page 16: ...ft 1 5m with foot valve above liquid level Control Digital Touchscreen or Mechanical Inlet Outlet 1 2 Male JIC Recommended Hose Minimum 1 2 inner diamter ID using quality approved fuel line materials Filter Torque Values Bowl Screws 8 Nm 70 8 in lbs Lid 8 Nm 70 8 in lbs Bleed Screw 4 Nm 35 4 in lbs Spare Parts Part Description 58 01010 Separ 01010 10 micron element 58 01030 Separ 01030 30 micron e...

Page 17: ... Q A MFG APPR ENG APPR CHECKED DRAWN DIMENSIONS ARE IN INCHES TOLERANCES FRACTIONAL 1 64 ANGULAR MACH BEND 0 2 TWO PLACE DECIMAL 01 THREE PLACE DECIMAL 005 PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF REVERSO PUMPS ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF REVERSO PUMPS IS PROHIBITED Part 19 2001 02 All Dimensions for...

Page 18: ...f priming 4 9 ft 1 5m with foot valve above liquid level Control Digital Touchscreen or Mechanical Inlet Outlet 3 4 Male JIC Recommended Hose Minimum 3 4 inner diamter ID using quality approved fuel line materials Filter Torque Values Bowl Screws 8 Nm 70 8 in lbs Lid 8 Nm 70 8 in lbs Bleed Screw 4 Nm 35 4 in lbs Spare Parts Part Description 59 01810 Separ 01810 10 micron element 59 01830 Separ 018...

Page 19: ... Q A MFG APPR ENG APPR CHECKED DRAWN DIMENSIONS ARE IN INCHES TOLERANCES FRACTIONAL 1 64 ANGULAR MACH BEND 0 2 TWO PLACE DECIMAL 01 THREE PLACE DECIMAL 005 PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF REVERSO PUMPS ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF REVERSO PUMPS IS PROHIBITED Part 21 2003 02 All Dimensions for...

Page 20: ...ioned Fuel water separator is clogged Service filter Rapid pump wear Pump has been run dry Ensure sufficient fuel supply Noisy operation Ensure sufficient fuel supply Air in the suction hose Check hose is submerged in the fuel or check for leak Motor does not turn or turns intermittently Control power not available Tripped circuit breaker on control board Pump failed and seized Motor failure Check...