TWO SIDED MODEL - CLEARANCES TO COMBUSTIBLES:
As above with 4" clearance to the end of the appliance
Always observe the approved clearance to combustible materials.
ELECTRICAL REQUIREMENTS
No external electrical power supply is required to operate the REVERSO "SUPREME"
DVD400 series if these models have a Millivolt gas control which uses the pilot flame to
generate enough electricity to operate the main burner whenever the manual switch provided
is on.
The DVD400 N/P models may also have a fan delay limit switch mounted in the control
compartment of the appliance. This switch is designed to delay the operation of the fan
until sufficient heat has built up, to avoid uncomfortable drafts and to hold the fan on for
several minutes after the burners have shut-off, extracting all of the usable heat.
When supplied with the optional circulating fan, the appliance does come fully equipped
with a 120 volt household plug which will supply electrical power for the air circulation
fan.
When connected to 120 volts, the appliance must be grounded in accordance with local
codes, with the current version of CSA C22.1 (in Canada) or the National Electrical
Code ANSI/NFPA 70.
Circulation fan: 120V / 60 hz - Variable speed fan.
NOTE: Operation of the fan increases the efficiency and the heat output of the appliance.
LOCATIONS
As noted earlier, these appliances are approved for bedroom installations.
They may be installed on any flat, hard surface combustible or otherwise. They can be
located within the allowable clearances to combustibles against the wall, in a corner or out in
the center of the room if desired. (See diagram # 1)
Don't forget to try to line up the center
point of the flue with an open joist space
above the unit, when planning to vent
vertically.