3. AUTO/MANUAL  

    This indicates current status 

1. Amount of discharge (Figure) 

    In usual status, there is no figure. But if a cup entered, outer shape appears and if  

    beer starts to be poured then internal level is rising up. 

   

4. Set time and amount of discharge (%) 

    In usual status, set time is displayed and when beer is discharged, then it is 

    expressed in percent   

5. Small, Medium, Large 

    This indicates current set value  

2. Displaying accumulated amount 

    If beer in Keg is completely consumed, then amount of sold beer is displayed and if 

    residual of beer is less than 10%, warning is displayed to prevent bubble of beer  

    from being burst out. 

■ Configuring the default display 

3. AUTO/MANUAL  

    This indicates current set value 

1. Amount of discharge (Figure) 

   

No figure in usual condition 

2. Accumulated discharge  

    This indicates accumulated discharge until now after KEG is replaced. In case of 

    20,000 CC KGE, when discharge amount exceeds 18,000 CC, then this blinks. Make 

    sure to press       button for more than 2 seconds to clear 

    KEG after it is replaced 

■ Stand by Mode 

Summary of Contents for V20

Page 1: ...User Manual Reverse Tap V20 ...

Page 2: ...aration Cautions 3 Name of each part 4 Cautions for installation 5 Operation Checklist before use 6 Button and displays 7 How to use dispenser 8 Miscellaneous Whole Structure 15 Cleaning 16 Errors handling 17 Product specification 19 2 ...

Page 3: ...e there might be risk by electrical shock and fire Miscellaneous Do not disassemble repair or alter this product at your discretion If you need repair make sure contact with service center Cautions Power management Turn off power when lightning strikes or when this product is not used for a long time If there occurs strange smell or smoke in the product make sure to turn off power immediately and ...

Page 4: ...N A M E S O F E A C H P A R T 4 Front side Outlet Menu Setting value movement Setting LCD Mode Setting Start Stop Cup sensor Gripper plate Nozzle LED ...

Page 5: ...required to prevent electrical leakage or shock In case that there is ant abnormality on the product No additional grounding is required if receptacle has its own earth terminal Otherwise a receptacle requires grounding If there is no grounding on receptacle make sure to connect grounding line to conducting area of the product and then connect it to metal water tap pipe or grounding line Do not us...

Page 6: ...ifferences in temperature Remove bubble in beverage pipe before using this product Bubble may be generated due to residual bubble in pipe Before using this product make sure to remove leakage in connecting area of various pipes Leakage in pipe connection may generate bubble Make sure to fit flow rate by adjusting valve in beverage pipe Bubble may be generated due to rapid flow rate Use this produc...

Page 7: ...urned off power is turned on along with long beep sound and then system is initialized 4 Start and Stop switches By pressing START button in manual mode while cup is recognized selected amount of beer is discharged When STOP button is pushed in auto or manual mode discharge of beer is stopped 5 Mode change and confirm switches This is a switch to change functions or save changed values 6 Changing ...

Page 8: ... value 2 Displaying accumulated amount If beer in Keg is completely consumed then amount of sold beer is displayed and if residual of beer is less than 10 warning is displayed to prevent bubble of beer from being burst out Configuring the default display 3 AUTO MANUAL This indicates current set value 1 Amount of discharge Figure No figure in usual condition 2 Accumulated discharge This indicates a...

Page 9: ...es count Mode 5 LED Lamp Mode 6 Cup Sensor Mode 7 KEG Volume Mode 8 DEMO Mode When you push the Right button 1 2 3 4 5 6 7 8 1 When you push the Left button 1 8 7 6 5 4 3 2 1 Mode Selection AUTO SMALL 5 8 SEC 362 5 cc T T 125 DAY 35 BUBBLE 0 0 0SEC LED Lamp MODE 1 CUP SENS DOUBLE KEG ALARM 0 1 SEC 6 25CC ALARM 18000 CC DEMO 5 8 SEC 362 CC Mode Display Auto Manual Size Setting Bubble Setting Sales ...

Page 10: ...ow to set mode AUTO Manual Auto Mode When a cup is recognized then beer is discharged in 0 5 second according to set values Large Medium Small Manual mode Although a cup is recognized beer is not discharged without pushing START button By pressing STOP button If you select Auto Manual mode by pushing left or right button then currently set mode is displayed By pushing button current status is blin...

Page 11: ... off set value is not changed nor return to original status Capacity change mode SMALL 5 8 sec 362 5 CC Changing amount of bubble By pushing left and right button select bubble amount mode then currently set mode is displayed By pushing button machine is ready to change set value sounding beep Change number by pushing Left number is changed into 1 2 3 0 1 2 3 This means that 1 indicates once befor...

Page 12: ...ed amount Today s amount This indicates accumulated amount of sold beer until now including whole amount and today s amount Displaying number of sold cups By pushing left and right button and select display mode for sold beer then currently selected mode is displayed Whenever beer is sold accumulated sales and today s sale are displayed in number of cups By pushing button for more than 2 seconds i...

Page 13: ...Purple Color LED Mode 8 Light Green Color LED Mode 9 Light blue Color LED Mode 10 Light purple Color LED Mode 11 Light yellow LED Changing method to recognize cup sensor CUP SENSOR DOUBLE By pushing left and right button select illumination change mode then currently set mode is displayed If you push button the machine is ready to change set value along with beep sound Mode is changed by pushing b...

Page 14: ...tting is completed along with beep sound Next make sure to save setting by pushing button for long time Setting is not changed although power is turned off Changing amount of discharge enables to change setting of discharging amount Amount of discharge can be changed every 0 05 CC using button ALARM is changed by every 100 cc This set value is for changing amount of alarm in waiting screen This se...

Page 15: ...W H O L E S T R U C T U R E 15 Reversetap Cup Whole Structure Drill if necessary Driver Wrenches Multi scissors Knife Lighter or torch Tools ...

Page 16: ...epeat the above action until clean water is discharged Lock CO2 gas valve and remove CO2 in washing container Separate head from washing container and put it into clean water Reference If the product is not used for a long time drain all beverage inside pipes and wash them using water and dry it Cautions Do not spray water on the product directly Do not clean it with benzene thinner Sodium Hypochl...

Page 17: ...olated from heat Replace pipe and keep it isolated from hear Is pipe connected to sol valve leaked Make sure to check fastening of clamp for pipe connection Is nozzle temperature high Make sure to keep nozzle temperature under proper level Is beer KEG significantly swaying during transportation Make sure to stabilize it for an hour before use Is pressure of CO2 too low Adjust the pressure under pr...

Page 18: ...aned Wash it regularly Is KEG well preserved Replace KEG before use Is a cup clean Use a clean cup The machine is not operated although the button is pushed Button may not be operated if it is touched by wet hands cleaned by damp cloth which means that button sensing part is abnormal due to moisture Make sure to remove moisture on button Screen of LCD monitor is abnormal Is abnormality still persi...

Page 19: ... 25 0 100 Discharged rate cc Alarm Capacity 18000 0 50000 Alarm value cc Default Setting Value Default setting value are as below Product specification Design and product specifications may be changed for quality improvement without notification Auxiliary products may vary depending on each model If you want to purchase additional auxiliary parts consult with shop where you purchased this product ...