background image

1.INTRODUCTION 

    

1.1 PRECAUTIONS 

    

1.2 TRANSPORT 

    

1.3 PACKAGE CONTENT 

    

1.4 USE 

2. DEVICE CHARACTERISTICS 

    

2.1 CONSTRUCTION AND PRINCIPLE OF OPERATION

    

2.2 DEVICE DIMENSIONS

    

2.3 DEVICE TECHNICAL DATA

3. ASSEMBLY

    

3.1 GENERAL PRINCIPLES

    

3.2 ROTATING MOUNTING BRACKET

    

3.3 FIXED HOLDERS

4. INSTALLATION INSTRUCTIONS 

    

4.1 CONNECTION OF THE DEVICE TO THE HYDAULIC SYSTEM 

    

4.2 CONNECTION OF THE DEIVCE TO THE ELECTRICAL SYSTEM 

5. PRECAUTIONS & WARNINGS
6. CONTROLS 
7. CONNECTION SCHEMES
8. TERMS OF WARRANTY

1. 

INTRODUCTION

Thank  you  very  much  for  purchasing  air  water  heater  S-3S.

 

We  would  like 

to congratulate you on excellent choice. Please read and keep this manual. 

1.1  

PRECAUTIONS

The buyer and the user of the air water heater Reventon Group brand should 
read  carefully  the  following  instructions  and  proceed  to  the  content 
recommendations.    Proceeding  due  to  the  following  instruction  guarantees 
the  correct  usage  and  safety.  In  case  of  any  doubts  please  contact  directly 
Reventon  Group  sp.  z  o.  o.  [Ltd.].  The  producer  reserves  the  rights  to  make 
changes  to  the  technical  documentation  without  previous  notice.  Reventon 
Group  sp.  z  o.  o.  [Ltd.]  is  not  responsible  for  the  damages  which  occur  due 
to  improper  installation,  not  keeping  the  device  in  repair  or  using  the  device 
out of line. The installation should be carried out by the professional installers, 
who possess the qualifications to install these types of devices. The installers 
are responsible for making the installation as instructed in the technical data. 
In  case  of  unserviceable  please  plug  out  the  device  and  contact 
with  the  authorizedfor  repair  person  or  the  supplier.  During  the  installation, 
use,  service  and  periodical  inspections  all  regulations  and  safety  rules 
must be followed.

1.2  TRANSPORT

During  the  acceptance  of  goods,  it  is  needed  to  check  the  device  to  exclude 
any damages. During the transport, it is needed to use the proper equipment, 
it is necessary to carry the device by two people. In case of any damages please fill 
in the damage report in presence of the supplier.

1.3 

PACKAGE CONTENT

-  h

eater

-  o

peration and maintenance manual and warranty card

1.4 

USE 

Heating  devices  Reventon  Group  S  series  are  used  to  heat  spaces  such  as: 
production  halls,  warehouses,  commercial  room,  service  spaces,  garages, 
workshops,  greenhouses,  tents,  shops,  malls,  shopping  malls  etc.    However, 
heating  devices  should  not  be  used  in  corrosive  environments  for  aluminum, 
copper  and  steel  as  well  as  in  highly  dusty  environments  (above  0.3  g/m³). 
The  devices  should  not  be  installed  in  rooms  where  they  would  be  exposed 
to high humidity or direct contact with water.

2. 

DEVICE CHARACTERISTICS 

2.1 

CONSTRUCTION AND PRINCIPLE OF OPERATION

Casing: 

made of galvanized steel casing, powder painted in RAL 9005 color.

Air stators: 

made of galvanized steel casing, powder painted in RAL 7048 color. 

It is possible to adjust manually the air stators to achieve the needed direction 
of the air flow.

Heating coil:

 made of copper and aluminum. Supplied by distribution working 

fluid,  which  circulates  through  the  coil  and  releases  heat  to  the  air.  The  coil 
has  the  following  technical  parameters:  the  maximum  temperature 
of the heating factor is 120°C; maximum pressure 1

.

6 MPa; headers diameter ¾”. 

Depending  on  dimensions  of  the  device  the  heaters  are  equipped 
with 1, 2 or 

 

3-row heating coils.

  ENG

TECHNICAL DOCUMENTATION

Axial blowing fan: 

made of galvanized steel.  The objective of the fan is to ensure 

air  flow  through  the  exchanger.  It  has  a  single-phase,  three  speed  motor 
with the following parameters: protection degree IP54, rate current 0.2 - 0.84 A 
(depending on model and operating mode). Model S1-3S has fan with diameter 
300 mm. Models S2-3S and S3-3S have fans with diameter 350 mm and S4-3S 
has fan with diameter 400 mm.

Rotating  mounting  bracket  (optional  equipment): 

enables  the  device 

to  be  installed  in  several  configurations  (depending  on  the  requirements) 
and the unit to be rotated in a horizontal plane.

Fixed  holders  (optional  equipment): 

made  of  steel,  element  for  mounting 

the  device  on  a  wall  or ceiling.  Solid  and  durable  construction,  possible 
to assemble device in parallel on the angle 60° and 45°.

2.2 

DEVICE DIMENSIONS

- S4-3S:

ź

: 660 mm

ź

: 696 mm

ź

: 384 mm

- S1-3S:

ź

 

4

52

 mm

ź

 

: 494

 mm

ź

 

3

05

 mm

- S2-3S 

and

 S3-3S:

ź

 

: 552

 mm

ź

 

: 545

 mm

ź

 

36

8

 mm

height (A)
width (B)
depth (C)

height (A)
width (B)
depth (C)

 

height (A)

 

width (B)

 

depth (C)

Summary of Contents for S1-3S

Page 1: ...Technical documentation AIR WATER HEATERS IN STEEL CASING S 3S SERIES MODELS S1 3S S2 3S S3 3S S4 3S ...

Page 2: ... 3PACKAGECONTENT heater operationandmaintenancemanualandwarrantycard 1 4USE Heating devices Reventon Group S series are used to heat spaces such as production halls warehouses commercial room service spaces garages workshops greenhouses tents shops malls shopping malls etc However heating devices should not be used in corrosive environments for aluminum copper and steel as well as in highly dusty ...

Page 3: ... 0 73 9 8 7 6 5 S2 3S 3 stage 2000 m3 h 0 5 10 15 20 20 1 18 4 16 7 15 0 13 4 28 0 31 0 34 0 37 0 39 9 0 88 0 81 0 73 0 66 0 59 7 6 5 4 3 80 60 90 70 40 30 120 90 S1 3S 3 stage 1400 m h S1 3S 3 stage 1400 m h S1 3S 3 stage 1400 m3 h S1 3S 3 stage 1400 m3 h S2 3S 3 stage 2000 m3 h S2 3S 3 stage 2000 m3 h for parameters 90 70 C and 0 C inlet air temperature max 120 90 C 0 C inlet air temperature III...

Page 4: ... h Pressure drop in the heat exchanger kPa Parameters Supply return water temperature C Dry bulb air inlet temperature C Heating capacity kW Dry bulb air outlet temperature C Water flow m h Pressure drop in the heat exchanger kPa Parameters Supply return water temperature C Dry bulb air inlet temperature C Heating capacity kW Dry bulb air outlet temperature C Water flow m h Pressure drop in the he...

Page 5: ...valveonthesupplyandreturnpipesofthedevice installationhastobesecuredagainstexcessiveincreaseofpressure it is recommended to check the leak tightness of the hydraulic system before plugging theelectricsupply 4 2 CONNECTIONOFTHEDEIVCETOTHEELECTRICALSYSTEM all works concerning electrical installation should be made by the qualified personnel who possess required authorizations to install electrical e...

Page 6: ...NTC 10K Communication RS485 Dimensions 86 x 86 x 13 3 mm Weight 270 g Degree of protection housing IP 20 Degree of protection external sensor IP 68 Programmable controller HMI 3 stagespeedcontrollerwiththermostatHC 3S FanspeedcontrollerHC Two wayvalvewithactuator ManualthermostatHC designed to change the single phase fan s speed voltage controlled in industrial supply and heating systems It is ava...

Page 7: ...e with actuator HC 6 Fan speed controller HC 7 Manual thermostat HC 8 Programmable controller HMI 9 Relay module RM 16A 10 External temperature sensor main switch and safety fuses are not included in the set Model 7 5 5 3 12 8 8 5 17 12 12 8 S1 3S S2 3S S3 3S S4 3S 7 5 5 3 12 8 8 5 RM 16 A 35 24 24 16 40 27 27 19 3 2 2 1 COOPERATION OF CONTROLLERS WITH EQUIPEMENT HC 3 A HC 5 A HC 7 A HMI HC3S HC 1...

Page 8: ......

Page 9: ......

Page 10: ......

Page 11: ......

Page 12: ......

Page 13: ......

Page 14: ...elimit VII Warranty does not cover the parts of the device subject to normal maintenanceandthefollowingcases a mechanicaldamageoftheproduct b defectsanddamagesthrough improperstorageortransport improper or non compliant use and maintenance i e inconsistent withthemanual using the device in the improper conditions too high humidity too high ortoolowtemperature impactofthesurrounding sunetc unauthor...

Page 15: ...Warranty card Reventon Group Sp z o o Ltd 556 Wyzwolenia Street 43 340 Kozy Poland ...

Page 16: ...Reventon Group Sp z o o Ltd 556 Wyzwolenia Street 43 340 Kozy Poland www reventongroup eu ...