Revel AIR ROMA Series Instruction Manual Download Page 12

12

All electric motors, including fan motors make some noise and may feel hot if touched – this is NOT A

FAULT. Ceiling fans tend to move during operation as they are not generally rigid-mounted.Rigid
mounted ceiling fans generate excessive vibration (which leads to noise) and stress on their mountings.

Movement in a ceiling fan is not uncommon and does not suggest the fan will fall down.

Some fans wobble more than others, even in the same model.

Fan Operation

A ceiling fan rotates much more slowly than an electric desk fan; it cools people effectively by introducing
slow movement into the otherwise still, hot air of a room, inducing natural evaporative cooling. Fans
never actually cool air, unlike air-conditioning equipment, but use significantly less power.

Normal Wear and Tear

Threaded components working slightly loose, or blade carriers becoming slightly bent due to vigorous
cleaning or bumping can cause extra wobble and noise. This is not covered under warranty, but a little
care and maintenance can reduce or prevent this problem.

Night Noises

This is the biggest cause of service calls, which are outside the manufacturer’s warranty. If a fan has a
fault, then it would be noticeable at ALL TIMES. Obviously when everything is quiet at night you will be
more inclined to hear small noises, which may not be noticeable at other times. Even slight signals
super imposed in your electricity supply for off peak hot water control may cause a change in the fan
motor noise, which is deemed normal. Solar power systems will cause extra humming in motors. In
both scenarios it is recommended that you explore options of adding a filter that can be installed to
eliminate these issues.

Dimming

The light kit supplied with this fan is NOT DIMMABLE.

Dimmers and solid state wall controllers can NOT BE USED for the operation of the fan motor.
This will instantly void any warranty provided.

IMPORTANT
FACTS

ROMA fan instructions_Oct20.qxp_Layout 1  15/10/20  11:19 am  Page 12

Summary of Contents for ROMA Series

Page 1: ...LLATION OPERATION MAINTENANCE WARRANTY INFORMATION Read Instructions carefully for safe installation and fan operation ROMA series Models ROMA48HSXX ROMA48HSB22XX ROMA56HSXX ROMA56HSB22XX ROMA48JHXX R...

Page 2: ...tely stop using the ceiling fan and refer the warranty information and contact details on page 13 of this document 10 The replacement of any parts should be performed by our service agent an appointed...

Page 3: ...t x 1 5 Screws for mounting bracket x 2 timber use only 6 Balancing kit x 1 set 7 Fan rotary switch capacitor x 1 set ROMA FAN WITHOUT LIGHT 1 Blades with mounting screws x 3 sets 2 Pre assembled fan...

Page 4: ...et x 1 5 Screws for mounting bracket x 2 timber use only 6 Balancing kit x 1 set 7 Fan rotary switch capacitor x 1 set ROMA FAN WITHOUT LIGHT 1 Blades with mounting screws x 3 sets 2 Pre assembled fan...

Page 5: ...s are 2 1m from the floor and 300mm from the wall and other obstructions to the blade tip The ceiling fan must be installed in a location so that the blades are a minimum 300mm spacing from the tip of...

Page 6: ...process for the remaining blades LIGHT KIT INSTALLATION NOTE FOR FAN MODELS WITHOUT LIGHT IGNORE THIS STEP 1 Install 2 x B22 globes into the lamp holders Max 15W Do not exceed the maximum wattage rat...

Page 7: ...additional all pole disconnection must be incorporated in the fixed wiring in accordance with the wiring rules NOTE Wiring diagram includes the light kit wiring The light wiring diagram and switch is...

Page 8: ...3000 Please follow the above wiring instructions before installation of remote kit A remote kit does not substitute for a terminal switch and doing so will void warranty ELECTRICAL WIRING DIAGRAM WIRI...

Page 9: ...will misalign canopy potentially causing sounds For best results leave screws about 4 5mm from hang sure bracket and position canopy into key lock slot J Hook Fan Connect the connector plugs together...

Page 10: ...ceiling fan can operate either in fan mode or reverse fan mode SUMMER MODE The reverse switch should be in the DOWN SUMMER position to rotate the fan in an anticlockwise direction The airflow will be...

Page 11: ...n disappear during this time CARE AND CLEANING Every 6 months periodic cleaning of your ceiling fan is the only maintenance required Use a soft brush or lint free cloth to avoid scratching the paint f...

Page 12: ...eaning or bumping can cause extra wobble and noise This is not covered under warranty but a little care and maintenance can reduce or prevent this problem Night Noises This is the biggest cause of ser...

Page 13: ...r unauthorised repairs of any kind by any person 4 Minor variations of speed may be evident even between same model of fans No two fans run exactly the same even across all speeds 5 Fan wobbles Any wo...

Page 14: ...www dekafans com au ROMA fan instructions_Oct20 qxp_Layout 1 15 10 20 11 19 am Page 14...

Reviews: