Table 8: Firmware Version 1_07_00 LED Codes
Firmware Version 1_07_00
LED Status
LED Description
When
Hub Status
Solid Blue
At Boot
Expansion Hub has power; Battery is >7V and is waiting to
initialize communications.
Solid Blue
Anytime
Hub is waiting for communication with the Driver Station Host.
Expansion Hub has power; Battery is >7V.
Solid Green with
one or more blue
blinks every
~5 Seconds
Anytime
Hub has power and active communication with the Android
Platform. The number of blue blinks is the same as the Hub’s
address.
The factory default address is 2 (
).
Blinking Blue
Anytime
Keep alive has timed out. Fault will clear when communication
resumes.
Blinking Orange
Anytime
Battery Voltage is lower than 7V. Either the 12V battery needs
to be charged, or the Expansion Hub is running on USB power
only. This fault will clear when battery voltage is raised above
7V.
This will not be overwritten by the keepalive timeout pattern.