•  must not be used in the immediate vicinity of flammable 

materials.

•  must not be set up in the immediate vicinity of pools, fountains, 

ponds, or similar bodies of water.

•  must not be immersed in water or other liquids.

•  must not be operated with wet hands; never look directly into 

the light source.

•  must never be covered.

•  must never be operated with an open housing, missing or 

damaged wiring compartment, or missing or damaged lens.

•  must never be left unattended while in operation or in the 

cooling phase.

•  must never be left unattended in the vicinity of children.

•  must never be sprayed or cleaned using a steam pressure 

cleaner since this can damage the insulation and seals.

•  must never be repaired by the user. Repairs must only be 

carried out by the manufacturer or an authorized service 

representative. 

TECHNICAL dATA

•  Output:  

HFGT120AE 

max. 

150W

 

HFGT400AE 

max. 

500W

 

•  Voltage:  

230V~, 50Hz

•  Protection class:  

IP44

•  Replacement illuminant:  

120W 

-

 

Item No. 0599940555

R7s

 

400W 

- Item No. 0599950555 

ILLUMINANT INSTALLATION

•  Loosen the screw on the top of the floodlight and swing the lens forward.

•  Remove the illuminant from the packaging.

•  Avoid touching it with bare hands since this causes grease stains which 

lead to overheating. Use a clean, dry, lint-free cloth.

•  Insert one end of the illuminant into the socket, press against it, and insert 

the other end of the illuminant into the socket. Ensure that the socket is not 

damaged.

•  Then close the lens and retighten the screw. 

INSTALLING THE GROUNd ANCHOR

•  Attach the ground anchor to the halogen floodlight securely using the 

mounting screw.

SETTING THE FLOOdLIGHT dIRECTION

•  Loosen the screws on the sides underneath the housing and adjust the 

floodlight direction and then retighten all screws.

The floodlight is now ready for use and can be operated under the intended 

conditions – it is essential that the requirements specified under “General 

Safety Instructions” in regards to the installation location are followed. 

REPLACING THE ILLUMINANT

You can find the technical data for the illuminant under “Technical Date” or on 

the type plate attached to the floodlight housing. 

•  Before opening the halogen floodlight, disconnect the power cable and 

allow the floodlight to cool down sufficiently!

•  Loosen the screw for the lens on top of the floodlight and swing the lens 

forward.

•  Remove the illuminant from the packaging.

•  Avoid touching it with bare hands since this causes grease stains which 

lead to overheating. Use a clean, dry, lint-free cloth.

•  Insert one end of the illuminant into the socket, press against it, and insert 

the other end of the illuminant into the socket. Ensure that the socket is not 

damaged.

•  Then close the lens and retighten the screw. 

CLEANING

•  Before cleaning the halogen floodlight, disconnect the power cable and 

allow the floodlight to cool down sufficiently.

•  Clean with a dry or slightly moist, clean, lint-free cloth and a mild detergent 

if required. Do not use cleaners that contain abrasives or solvents.

•  If required, the illuminant can be cleaned with a lint-free cloth moistened 

with ethyl alcohol. ATTENTION! After cleaning the illuminant with ethyl 

alcohol, it must be allowed to air dry for at least 20 minutes. 

MAINTENANCE

•  Check the plug, power cable, and housing of the halogen floodlight for 

damage before each use. If the lens is damaged it must be replaced 

immediately.

•  Clean any dirt from the housing or the lens immediately, since it could 

cause overheating.

ANL_0593054555_0593064555.indd   8-9

25.07.2012   12:55:03

Summary of Contents for HFGT120AE

Page 1: ...CZ Halogenov reflektor 150 500W IP44 se zapichovac m dr kem do zem N vod pro mont a obsluhu EE Halogeenvalgusti 150 500W IP44 maasse torgatava varrega Paigaldus ja kasutusjuhend LV Halog nstavlampa 1...

Page 2: ...fernt aufstellen Dies gilt insbesondere f r das Netzkabel dieses darf nicht angestrahlt werden oder in Ber hrung mit dem Metallgeh use kommen immer ausreichend abk hlen lassen das Geh use des Fluters...

Page 3: ...die Fassung ein Achten Sie darauf dass die Fassung nicht verbogen wird Schlie en Sie anschlie end die Schutzscheibe und ziehen Sie die Schraube wieder fest ErdspieSS montieren Befestigen Sie den Erdsp...

Page 4: ...ollows or depressions since water can collect there DE GB eventuell ein mildes Reinigungsmittel verwenden Keine scheuer oder l sungsmittelhaltigen Reinigungsmittel anwenden Wenn n tig kann das Leuchtm...

Page 5: ...des underneath the housing and adjust the floodlight direction and then retighten all screws The floodlight is now ready for use and can be operated under the intended conditions it is essential that...

Page 6: ...suivantes avant de mettre le luminaire halog ne en service et conservez les pour pouvoir les relire ult rieurement Emploi conforme sa destination IP 44 Le luminaire halog ne est prot g contre les pro...

Page 7: ...rre Fixer la perche de mise la terre l aide de la vis de fixation solidement au spot halog ne R glage de la direction du faisceau Desserrer les vis lat rales sous le bo tier r gler la direction du fai...

Page 8: ...seguridad El foco hal geno Debe situarse a m s de 1m de cualquier superficie iluminada Esto es especialmente aplicable para el cable el ctrico que en ning n momento debe estar iluminado por el foco ni...

Page 9: ...ierra Fije la varilla de toma de tierra al foco hal geno con el tornillo de sujeci n Ajuste de la direcci n de iluminaci n Afloje los tornillos laterales debajo de la carcasa oriente el foco como dese...

Page 10: ...europee CE pertinenti Avvertenze generali sulla sicurezza Il faretto alogeno deve essere disposto sempre ad almeno 1m di distanza dalle superfici che illumina Ci vale in particolare per il cavo di ali...

Page 11: ...o asciutto e non filaccioso Inserire un estremit della lampada nel portalampada spingerla dentro e inserire anche l altra estremit nel portalampada Procedere con cautela per non deformare il portalamp...

Page 12: ...o e mantenha o manual sempre disposi o para poder utiliz lo no futuro Utiliza o para o fim especificado IP 44 O holofote halog neo est protegido contra salpicos de gua classe IP44 e adequado para a ut...

Page 13: ...no limpo seco e sem fiapos Coloque uma extremidade da l mpada no porta l mpadas pressione a l mpada contra o porta l mpadas e em seguida coloque a outra extremidade da l mpada no porta l mpadas Ter cu...

Page 14: ...dan nce a a daki kullanma k lavuzunu dikkatli bir ekilde okuyunuz ve daha sonra da bakmak i in iyi saklay n z Amac na uygun kullan m IP 44 Halojen projekt r s rayan suya kar korunmu tur IP44 ve d meka...

Page 15: ...ediniz Toprak saplamas n sabitleme c vatas arac l yla halojen projekt re s k ca sabitleyiniz I k yayma y n n n ayarlanmas G vde alt ndaki yan vidalar gev etiniz istedi iniz lamba k yayma y n n ayarla...

Page 16: ...g vdesinde bir hasar olup olmad n kontrol ediniz Zarar g rm koruyucu camlar derhal de i tiriniz A r s nmaya neden olduklar ndan g vde veya koruyucu cam zerindeki kirleri derhal temizleyiniz IP44 IP 44...

Page 17: ...32 33 GR GR HFGT120AE max 150W HFGT400AE max 500W 230V 50Hz IP44 120W 0599940555 R7s 400W 0599950555 ANL_0593054555_0593064555 indd 32 33 25 07 2012 12 55 09...

Page 18: ...34 35 GR RU 20 IP44 IP 44 IP44 1 IP44 230 ANL_0593054555_0593064555 indd 34 35 25 07 2012 12 55 09...

Page 19: ...36 37 RU RU HFGT120AE max 150W HFGT400AE max 500W 230B 50 IP44 120W 0599940555 R7s 400W 0599950555 ANL_0593054555_0593064555 indd 36 37 25 07 2012 12 55 10...

Page 20: ...nych powierzchni Dotyczy to w szczeg lno ci przewodu sieciowego kt ry nie mo e by na wietlany ani dotyka do metalowej obudowy zawsze pozostawia do ostygni cia obudowa reflektora mo e si bardzo mocno n...

Page 21: ...szyb ochronn i dokr ci rub Monta szpikulca Zamontowa szpikulec do lampy halogenowej za pomoc ruby mocuj cej Ustawianie kierunku padania wiat a Odkr ci boczne ruby pod obudow ustawi dany kierunek pada...

Page 22: ...zpe nostn pokyny Halogenov z i v dy postavte nebo instalujte tak aby byl dodr en minim ln odstup 1m To plat zejm na pro s ov kabel kter nesm b t vystaven p mem mu sv tlen mu z en z i e a nesm se dot k...

Page 23: ...moc roubu pevn na halogenov z i Nastaven sm ru z en Uvoln te bo n rouby pod krytem nasm rujte z i a n sledn v echny rouby op t pevn ut hn te Nyn je z i p ipraven k provozu a m ete jej zprovoznit na V...

Page 24: ...ast v hemalt 1m kaugusele See kehtib eriti v rgujuhtme kohta sest juhe ei tohi olla soojuskiirguse piirkonnas v i sattuda kontakti metallkorpusega laske seadmel alati piisavalt maha jahtuda halogeenpr...

Page 25: ...kruvi taas kinni Maavaia monteerimine Kinnitage maavai kinnituskruvi abil tugevasti halogeenkiirguri k lge Valguskiirguse suuna seadistamine Keerake korpuse alak ljel olevad k lgmised kruvid lahti se...

Page 26: ...juma Direkt vu pras b m Visp r ji dro bas nor d jumi Halog na starmeti vienm r novietot vismaz 1m no apgaismojam s virsmas pa i elektrot kla kabelis nedr kst tikt apstarots vai non kt saskarsm ar met...

Page 27: ...halog na starme a ar mont as skr ves pal dz bu Gaismas virziena ieregul ana Atskr v jiet korpusa apak eso s s nu skr ves ieregul jiet v lamo starme a gaismas virzienu un p c tam atkal pievelciet skr v...

Page 28: ...lavimus Bendri saugumo nurodymai Halogenin viestuv statyti visada ma iausiai 1m atstumu nuo ap vie iam pavir i Ypa kalbant apie elektros laid kurio negalima ap viesti arba liesti metaliniu korpusu vis...

Page 29: ...uvo viesos krypt ir v l priver kite visas ver les Dabar viestuvas yra paruo tas ir gali b ti naudojamas J s numatytoje vietoje tai darydami atsi velkite pastatymo vietos reikalavimus nurodytus Bendruo...

Page 30: ...akiranje ili tome HR sli nim ne montirajte ga u jame udubljenja jer se tamo mo e voda sakupiti nemojte ga uporabiti u neposrednoj blizini zapaljivih tvari Nemojte ga postaviti u neposrednoj blizini ba...

Page 31: ...arulji to mo e prouzro iti pregrijanje Uporabite istu suhu krpu bez pahuljica Umetnite jedan kraj arulje u grlo pritisnite je i umetnite drugi kraj arulje u grlo Pazite da se grlo ne bi savilo Nakon...

Page 32: ...ne montirajte ga u jame udubljenja jer se tamo mo e voda sakupiti nemojte da ga upotrebiti u neposrednoj blizini zapaljivih materijala Nemojte da ga postavite u neposrednoj blizini bazena vodoskoka je...

Page 33: ...na sijalici to mo e prouzro iti pregrejanje Upotrebite istu suvu krpu bez pahuljica Umetnite jedan kraj sijalice u grlo pritisnite je i umetnite drugi kraj sijalice u grlo Pazite da se grlo ne bi sav...

Page 34: ...i aparatul n nc peri cu pericol de explozie de RO ex n ateliere de t mpl rie n hale de l cuire sau altele asem n toare Nu monta i n ad ncituri sau gropi deoarece acolo se poate aduna apa nu utiliza i...

Page 35: ...nge i lampa cu m na fiindc petele de gr sime r mase i pot provoca supra nc lzirea Utiliza i o c rp curat uscat i care nu las scame Introduce i unul din capetele l mpii n soclu ap sa i l s intre n untr...

Page 36: ...zem vagy hasonl k HU ne szerelje fel g dr kbe m lyed sekbe mert ott v z gy lhet ssze ne haszn lja gy l kony anyagok k zvetlen k zel ben Ne ll tsa fel f rd medence sz k k t t vagy hasonl v zfel let k...

Page 37: ...n amely t lhev l st okozhatna Haszn ljon egy tiszta sz raz sz szmentes rongyot Helyezze az izz egyik v g t a foglalatba nyomja be s helyezze az izz m sik v g t a foglalatba gyeljen r hogy ne g rb lj...

Page 38: ...v neposredni bli ini gorljivih materialov nikoli ne postavljajte v neposredni bli ini bazen kov za otroke fontanami ribniki ali podobnimi vodotoki SI ne potapljajte v vodo ali v druge teko ine ne upo...

Page 39: ...o krpo Vstavite konec svetilnega sredstva v dr alo pritisnite proti temu in vstavite drugi konec svetilnega sredstva v dr alo Bodite pozorni na to da dr ala nista upognjena Na koncu zaprite e varnostn...

Page 40: ...78 79 BG HFGT120AE max 150W HFGT400AE max 500W 230V 50Hz IP44 120W N 0599940555 R7s 400W N 0599950555 BG ANL_0593054555_0593064555 indd 78 79 25 07 2012 12 55 19...

Page 41: ...80 81 BG 20 ANL_0593054555_0593064555 indd 80 81 25 07 2012 12 55 20...

Page 42: ...82 83 ANL_0593054555_0593064555 indd 82 83 25 07 2012 12 55 20...

Page 43: ...REV Ritter GmbH Frankenstr 1 4 D 63776 M mbris www rev biz ANL_0593054555_0593064555 indd 84 25 07 2012 12 55 20...

Reviews: