CAUTION 

notice warns of a hazard. It calls 

attention to an operating procedure, practice, 
or the like that, if not correctly performed or 
adhered to, could result in damage to the 
product or loss of important data. Do not 
proceed beyond a 

CAUTION 

notice until the 

indicated conditions are fully understood and 
met.  

WARNING  

 

 

A WARNING notice warns of a hazard. It 
calls attention to an operating procedure, 
practice, or the like that, if not correctly 
performed or adhered to, could result in 
personal injury or death. Do not proceed 
beyond a WARNING notice until the 
indicated conditions are fully understood 
and met.

 

 
 

 
 
 

 
 

Recycling 

 

For recycling contact Restek or 
your local Restek distributor. 
 
 
 
 
 

 
 
 
 

 
 
 
 
Sound Pressure

  

 

Sound pressure L

pA

 = 70.1 dB(A)  

Summary of Contents for 22358

Page 1: ...Electronic Crimping Tools Models 22358 22359 22360 22362 Operation Guide 1...

Page 2: ...of important data Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met WARNING A WARNING notice warns of a hazard It calls attention to an operating proce...

Page 3: ...p 5 Operation 5 Storage and Shipping 9 Fault Conditions 9 Maintenance Repair 10 This operation manual applies to the following products Model Number 11mm Electronic Crimper 22358 20mm Electronic Crimp...

Page 4: ...ttery Warnings Risk of burns battery may explode or catch fire if mishandled Do not disassemble or dispose of in fire Use only the manufacturer supplied 7 5 volt DC power supply and charge the battery...

Page 5: ...ery The battery must be charged before the crimper or decapper can be used The 7 5 volt DC power supply comes with a set of clips to fit power outlets for most countries Slide the correct clip into th...

Page 6: ...y to engage the motor This switch must be held down until the crimp is complete If the switch is released early the crimper will retract If the Status LED blinks amber after the cycle is complete a fa...

Page 7: ...apper does the rest of the work To adjust the 20mm decapper just make sure that the stroke is long enough to remove the cap When to Recharge the Battery The 6 4 volt battery pack for the electronic cr...

Page 8: ...he position sensor to be set to zero and resets the processor Factory Reset This requires pressing the reset button while both the and buttons are also down The green LED will blink one time and the c...

Page 9: ...ool cycles Early trigger release the tool retracted before completing cycle Try again making sure to hold the button down until the tool is returning to the home position Status 3 Amber Blinks but too...

Page 10: ...Avoid permitting metal parts of the crimping tool come into contact with corrosive material during use If they do try to wipe them clean with a suitable mild neutralizing solution Battery Replacement...

Page 11: ...ormation 11mm decapper leaves caps hanging on vials Decapper adjustment is too low Adjust the decapper to a higher setting by pressing the plus button Jaws are worn or broken The decapper will have to...